Energy Efficiency Regulations, 2016 (SOR/2016-311)
Full Document:
- HTMLFull Document: Energy Efficiency Regulations, 2016 (Accessibility Buttons available) |
- XMLFull Document: Energy Efficiency Regulations, 2016 [1222 KB] |
- PDFFull Document: Energy Efficiency Regulations, 2016 [4041 KB]
Regulations are current to 2024-10-30 and last amended on 2024-03-27. Previous Versions
PART 2Energy-Using Products (continued)
DIVISION 1Household Appliances (continued)
SUBDIVISION JMicrowave Ovens (continued)
Marginal note:Information
69 For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a microwave oven:
(a) its type;
(b) its volume, expressed in litres (cubic feet); and
(c) its standby power, expressed in watts, as collected in accordance with CSA C388-15 or 10 C.F.R. Appendix I.
SUBDIVISION KMiscellaneous Refrigeration Products
Marginal note:Definitions
70 The following definitions apply in this Subdivision.
- 10 C.F.R. Appendix A
10 C.F.R. Appendix A means Appendix A to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Refrigerators, Refrigerator-Freezers, and Miscellaneous Refrigeration Products, as amended from time to time, except for the waiver referred to in section 7 of that Appendix. (appendice A 10 C.F.R.)
- 10 C.F.R. §430.32(aa)(1)
10 C.F.R. §430.32(aa)(1) means the table to paragraph 430.32(aa)(1) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(aa)(1))
- 10 C.F.R. §430.32(aa)(2)
10 C.F.R. §430.32(aa)(2) means the table to paragraph 430.32(aa)(2) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(aa)(2))
- miscellaneous refrigeration product
miscellaneous refrigeration product means a household refrigeration product, which includes a cooler and combination cooler refrigeration product, but does not include a refrigerator, refrigerator-freezer or freezer. (appareil de réfrigération divers)
Marginal note:Type
71 For the purposes of these Regulations, a miscellaneous refrigeration product is one of the following types:
(a) if it was manufactured on or after January 1, 2008 and before October 28, 2019, a type described in any of the product types (19) or (20) of Table 1 to CSA C300-15; or
(b) if it is manufactured on or after October 28, 2019, a cooler of a product class described in 10 C.F.R. §430.32(aa)(1) or a combination cooler refrigeration product of a product class described in 10 C.F.R. §430.32(aa)(2).
Marginal note:Energy-using product
72 (1) A miscellaneous refrigeration product is prescribed as an energy-using product.
Marginal note:Limits
(2) However, for the purposes of sections 4, 5, 13 to 15 and 73, a miscellaneous refrigeration product is not considered to be an energy-using product unless
(a) it is manufactured on or after January 1, 2008 and before October 28, 2019, and is a type (19) or (20) as described in Table 1 to CSA C300-15; or
(b) it is manufactured on or after October 28, 2019.
Marginal note:Energy efficiency standard
73 (1) The energy efficiency standards set out in column 3 of the table to this section apply to miscellaneous refrigeration products described in column 1 that are manufactured during the periods set out in column 4.
Marginal note:Testing standard
(2) A miscellaneous refrigeration product complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a miscellaneous refrigeration product as defined in section 70.
Item Column 1 Column 2 Column 3 Column 4 Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Miscellaneous refrigeration products CSA C300-12 CSA C300-12, Table 1 On or after January 1, 2008 and before September 15, 2014 2 Miscellaneous refrigeration products CSA C300-15 CSA C300-15, Table 1 On or after September 15, 2014 and before October 28, 2019 3 Miscellaneous refrigeration products – coolers 10 C.F.R. Appendix A 10 C.F.R. §430.32(aa)(1) On or after October 28, 2019 4 Miscellaneous refrigeration products – combination cooler refrigeration products 10 C.F.R. Appendix A 10 C.F.R. §430.32(aa)(2) On or after October 28, 2019
Marginal note:Information
74 (1) For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a miscellaneous refrigeration product:
(a) its type;
(b) its adjusted volume; and
(c) its annual energy consumption expressed in kilowatt-hours.
Marginal note:Standard
(2) The information must be collected in accordance with one of the following standards:
(a) CSA C300-12 if the product was manufactured on or after January 1, 2008 and before September 15, 2014;
(b) CSA C300-15 if the product was manufactured on or after September 15, 2014 and before October 28, 2019; or
(c) 10 C.F.R. Appendix A if the product is manufactured on or after October 28, 2019.
SUBDIVISION LCeiling Fans
Marginal note:Definitions
75 The following definitions apply in this Subdivision.
- 10 C.F.R. Appendix U
10 C.F.R. Appendix U means Appendix U to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Ceiling Fans, as amended from time to time. (appendice U 10 C.F.R.)
- 10 C.F.R. §430.32(s)(2)(i)
10 C.F.R. §430.32(s)(2)(i) means the table to subparagraph 430.32(s)(2)(i) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(s)(2)(i))
- ceiling fan
ceiling fan means a non-portable device that is suspended from a ceiling for circulating air via the rotation of fan blades. It does not include
(a) a ceiling fan if the plane of rotation of the fan blades is greater than 45 degrees from horizontal;
(b) a centrifugal ceiling fan;
(c) a belt-driven ceiling fan;
(d) an oscillating ceiling fan; and
(e) a ceiling fan with a maximum rotational speed of 90 RPM and a maximum airflow of 52.1 cubic metres/minute (1840 cubic feet/minute). (ventilateur de plafond)
Marginal note:Type
76 For the purposes of these Regulations, a ceiling fan is one of the following types:
(a) very small diameter;
(b) standard;
(c) hugger;
(d) high-speed small-diameter; or
(e) large-diameter.
Marginal note:Energy-using product
77 (1) A ceiling fan is prescribed as an energy-using product.
Marginal note:Limits
(2) However, for the purposes of sections 4, 5 and 78, a ceiling fan is not considered to be an energy-using product unless it is manufactured on or after January 21, 2020.
Marginal note:Energy efficiency standard
78 (1) The energy efficiency standard for a ceiling fan is the standard as set out in 10 C.F.R. §430.32(s)(2)(i).
Marginal note:Testing standard
(2) A ceiling fan complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix U that are applicable to a ceiling fan as defined in section 75.
Marginal note:Information
79 For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix U and provided to the Minister in respect of a ceiling fan:
(a) its type;
(b) its blade span;
(c) its air flow at high speed;
(d) its ceiling fan efficiency; and
(e) its standby power consumption expressed in watts.
[80 to 106 reserved]
DIVISION 2Air Conditioners, Condensing Units and Chillers
Interpretation
Marginal note:Definitions
107 The following definitions apply in this Division.
- CSA C656-05
CSA C656-05 means the CSA standard CAN/CSA-C656-05 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-05)
- CSA C656-14
CSA C656-14 means the CSA standard CSA-C656-14 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-14)
- CSA C746-06
CSA C746-06 means the CSA standard CAN/CSA-C746-06 entitled Performance Standard for Rating Large and Single Packaged Vertical Air Conditioners and Heat Pumps. (CSA C746-06)
- CSA C746-98
CSA C746-98 means the CSA standard CAN/CSA-C746-98 entitled Performance Standard for Rating Large Air Conditioners and Heat Pumps. (CSA C746-98)
- small-duct and high-velocity
small-duct and high-velocity, with respect to a single package central air conditioner or a split-system central air conditioner, means one that has an indoor blower and coil combination that
(a) produces at least 300 Pa (1.2 inches of water) external static pressure when operated at an air volume rate of 104 to 165 L/s (220 to 350 cubic feet/minute) per nominal ton of cooling; and
(b) uses room outlets that produce velocities greater than 5 m/s (1,000 feet/minute) and that each have an area less than 39 cm2 (6 square inches). (à grand débit et à petits conduits)
- space-constrained
space-constrained, with respect to a single package central air conditioner or a split system central air conditioner, means one that
(a) has a cooling capacity that is less than or equal to 8.79 kW (30,000 Btu/h); and
(b) has an outdoor or indoor unit that has an overall displacement or at least two overall exterior dimensions that
(i) are substantially smaller than those of other units of a similar cooling capacity that are usually installed in single family homes, and
(ii) if increased, would result in a considerable increase in the usual cost of installation or in a significant loss in the utility of the product to the consumer. (à espace restreint)
- 10 C.F.R. Appendix M
10 C.F.R. Appendix M means Appendix M to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M 10 C.F.R)
- 10 C.F.R. Appendix M1
10 C.F.R. Appendix M1 means Appendix M1 to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M1 10 C.F.R.)
- Date modified: