Energy Efficiency Regulations, 2016 (SOR/2016-311)

Regulations are current to 2025-10-14 and last amended on 2025-10-09. Previous Versions

PART 2Energy-Using Products (continued)

DIVISION 6Water Heaters (continued)

SUBDIVISION AElectric Water Heaters (continued)

Marginal note:Early compliance

 An electric water heater that is manufactured on or after May 6, 2028 and before May 6, 2029 is deemed to satisfy the requirements of sections 372 and 373 if it satisfies the requirements of those sections that would have applied to the electric water heater if it had been manufactured on or after May 6, 2029.

SUBDIVISION BGas-Fired Storage Water Heaters

Marginal note:Definitions

 The following definitions apply in this Subdivision.

CSA P.3-04

CSA P.3-04 means the CSA standard CAN/CSA-P.3-04 entitled Testing Method for Measuring Energy Consumption and Determining Efficiencies of Gas-Fired Storage Water Heaters. (CSA P.3-04)

gas-fired storage water heater

gas-fired storage water heater[Repealed, SOR/2025-110, s. 50]

replacement unit

replacement unit means a commercial gas-fired storage water heater that is marked for replacement installations only. (unité de remplacement)

Marginal note:Type

 For the purpose of these Regulations, a gas-fired storage water heater is one of the following types:

  • (a) household, if it has an input rate of less than or equal to 21.97 kW (75,000 Btu/h); or

  • (b) commercial, if it is has an input rate of greater than 21.97 kW (75,000 Btu/h).

Marginal note:Energy-using product

  •  (1) A gas-fired storage water heater is prescribed as an energy-using product.

  • Marginal note:Limits

    (2) However, for the purposes of sections 4, 5 and 376, a gas-fired storage water heater is not considered to be an energy-using product unless

    • (a) it is a household gas-fired storage water heater that is manufactured on or after February 3, 1995; or

    • (b) it is a commercial gas-fired storage water heater that is manufactured on or after July 1, 2023.

Marginal note:Energy-efficiency standards — household

  •  (1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to household gas-fired storage water heaters described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Testing standard — household

    (2) A household gas-fired storage water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 1 that are applicable to a gas-fired storage water heater as defined in subsection 369(1).

  • Marginal note:Energy efficiency standards — commercial

    (3) The energy efficiency standards set out in column 3 of Table 2 to this section apply to commercial gas-fired storage water heaters described in column 1 that are manufactured on or after July 1, 2023.

  • Marginal note:Testing standard — commercial

    (4) A commercial gas-fired storage water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 2 that are applicable to a gas-fired storage water heater as defined in subsection 369(1).

    TABLE 1

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture
    1Household gas-fired storage water heatersCSA P.3-04Energy factor of ≥ 0.67 – 0.0005 VrOn or after February 3, 1995 and before December 31, 2016
    2Household gas-fired storage water heatersCSA P.3-04Energy factor of ≥ 0.675 – 0.00039 VrOn or after December 31, 2016 and before January 1, 2018
    3Household gas-fired storage water heaters that have a first-hour rating of < 68 L (18 US gallons)

    CSA P.3-04 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.675 – 0.00039 Vr; or

    • (b) uniform energy factor of ≥ 0.3456 –0.00053 Vs

    On or after January 1, 2018 and before May 6, 2029
    4Household gas-fired storage water heaters that have a first-hour rating of ≥ 68 L (18 US gallons) but < 193 L (51 US gallons)

    CSA P.3-04 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.675 – 0.00039 Vr; or

    • (b) uniform energy factor of ≥ 0.5982 – 0.00050 Vs.

    On or after January 1, 2018 and before May 6, 2029
    5Household gas-fired storage water heaters that have a first-hour rating of ≥ 193 L (51 US gallons) but < 284 L (75 US gallons)

    CSA P.3-04 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.675 – 0.00039 Vr; or

    • (b) uniform energy factor of ≥ 0.6483 – 0.00045 Vs.

    On or after January 1, 2018 and before May 6, 2029
    6Household gas-fired storage water heaters that have a first-hour rating of ≥ 284 L (75 US gallons)

    CSA P.3-04 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.675 – 0.00039 Vr; or

    • (b) uniform energy factor of ≥ 0.692 – 0.00034 Vs.

    On or after January 1, 2018 and before May 6, 2029
    7Household gas-fired storage water heaters10 C.F.R. Appendix E

    Must have at least one of the following:

    • (a) uniform energy factor of ≥ 0.3456 − 0.00053 Veff, if draw pattern is very-small-usage;

    • (b) uniform energy factor of ≥ 0.5982 − 0.00050 Veff, if draw pattern is low-usage;

    • (c) uniform energy factor of ≥ 0.6483 − 0.00045 Veff, if draw pattern is medium-usage; or

    • (d) uniform energy factor of ≥ 0.692 − 0.00034 Veff, if draw pattern is high-usage.

    On or after May 6, 2029

    TABLE 2

    Column 1Column 2Column 3
    ItemEnergy-using ProductTesting StandardEnergy Efficiency Standard
    1Commercial gas-fired storage water heaters, other than replacement units, that have an input rate of > 21.97 kW (75,000 Btu/h) but ≤ 30.5 kW (105,000 Btu/h), have a Vr of ≤ 454 L (120 US gallons), use single-phase power and limit water temperatures to < 82°C (180°F)CSA P.3-15Uniform energy factor ≥ 0.8107-0.00021 Vs
    2Commercial gas-fired storage water heaters that are replacement units, have an input rate of > 21.97 kW (75,000 Btu/h) but ≤ 30.5 kW (105,000 Btu/h), have a Vr of ≤ 454 L (120 US gallons), use single-phase power and limit water temperatures to < 82°C (180°F)CSA P.3-15Uniform energy factor ≥ 0.6597-0.00024 Vs
    3Commercial gas-fired storage water heaters, other than replacement units, that have a Vr of > 530 L (140 US gallons)10 C.F.R. Appendix AThermal efficiency ≥ 90%
    4Commercial gas-fired storage water heaters that are replacement units and that have a Vr of > 530 L (140 US gallons)10 C.F.R. Appendix AThermal efficiency ≥ 80%
    5Commercial gas-fired storage water heaters, other than those described in items 1 and 3, that are not replacement units10 C.F.R. Appendix A

    Thermal efficiency ≥ 90%

    Standby loss ≤ 0.84 (1.25 Q + 16.57√Vs)

    6Commercial gas-fired storage water heaters, other than those described in items 2 and 4, that are replacement units10 C.F.R. Appendix A

    Thermal efficiency ≥ 80%

    Standby loss ≤ 1.25 Q + 16.57√Vs

 For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas-fired storage water heater described in column 1.

TABLE

Column 1Column 2Column 3
ItemEnergy-using ProductTesting StandardInformation
1Household gas-fired storage water heaters that are manufactured on or after February 3, 1995 and before January 1, 2018CSA P.3-04
  • (a) input rate, in kW (Btu/h);

  • (b) recovery efficiency;

  • (c) type of fuel used;

  • (d) annual energy consumption, in kJ (Btu);

  • (e) first-hour rating, in L;

  • (f) Vr; and

  • (g) energy factor.

2Household gas-fired storage water heaters that are manufactured on or after January 1, 2018 and before May 6, 2029

CSA P.3-04, if a certification body has verified that the product is in compliance with the energy efficiency standard set out in any of paragraphs 3(a), 4(a), 5(a) and 6(a) of Table 1 to section 376

CSA P.3-15, if a certification body has verified that the product is in compliance with the energy efficiency standard set out in any of paragraphs 3(b), 4(b), 5(b) and 6(b) of Table 1 to section 376

  • (a) input rate, in kW (Btu/h);

  • (b) recovery efficiency;

  • (c) type of fuel used;

  • (d) annual energy consumption, in kJ (Btu);

  • (e) first-hour rating, in L;

  • (f) Vr;

  • (g) energy factor, if a certification body has verified that the product is in compliance with the energy efficiency standard set out in any of paragraphs 3(a), 4(a), 5(a) and 6(a) of Table 1 to section 376; and

  • (h) uniform energy factor and Vs, if a certification body has verified that the product is in compliance with the energy efficiency standard set out in any of paragraphs 3(b), 4(b), 5(b) and 6(b) of Table 1 to section 376.

2.1Household gas-fired storage water heaters that are manufactured on or after May 6, 202910 C.F.R. Appendix E
  • (a) input rate, in kW (Btu/h);

  • (b) recovery efficiency;

  • (c) type of fuel used;

  • (d) annual energy consumption, in kJ (Btu);

  • (e) first-hour rating, in L;

  • (f) Vr;

  • (g) Veff; and

  • (h) uniform energy factor.

3Commercial gas-fired storage water heaters that have an input rate of > 21.97 kW (75,000 Btu/h) but ≤ 30.5 kW (105,000 Btu/h), have a Vr of ≤ 454 L (120 US gallons), use single-phase power, limit water temperatures to < 82°C (180°F) and are manufactured on or after July 1, 2023CSA P.3-15
  • (a) uniform energy factor;

  • (b) Vr;

  • (c) Vs;

  • (d) input rate, in kW (Btu/h);

  • (e) type of fuel used; and

  • (f) information that indicates whether the product is a replacement unit.

4Commercial gas-fired storage water heaters with a Vr of > 530 L (140 US gallons) that are manufactured on or after July 1, 202310 C.F.R. Appendix A
  • (a) thermal efficiency;

  • (b) Vr;

  • (c) Vs;

  • (d) input rate, in kW (Btu/h);

  • (e) type of fuel used; and

  • (f) information that indicates whether the product is a replacement unit.

5Commercial gas-fired storage water heaters, other than those described in items 3 and 4, that are manufactured on or after July 1, 202310 C.F.R. Appendix A
  • (a) thermal efficiency;

  • (b) standby loss, in W;

  • (c) Vr;

  • (d) Vs;

  • (e) input rate, in kW (Btu/h);

  • (f) type of fuel used; and

  • (g) information that indicates whether the product is a replacement unit.

 