Energy Efficiency Regulations, 2016 (SOR/2016-311)
Full Document:
- HTMLFull Document: Energy Efficiency Regulations, 2016 (Accessibility Buttons available) |
- XMLFull Document: Energy Efficiency Regulations, 2016 [1222 KB] |
- PDFFull Document: Energy Efficiency Regulations, 2016 [4041 KB]
Regulations are current to 2024-10-30 and last amended on 2024-03-27. Previous Versions
PART 2Energy-Using Products (continued)
DIVISION 3Heat Pumps (continued)
SUBDIVISION DPackaged Terminal Heat Pumps
Marginal note:Definitions
199 The following definitions apply in this Subdivision.
- CSA C744-04
CSA C744-04 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2004/CAN/CSA-C744-04 entitled Standard for Packaged Terminal Air Conditioners and Heat Pumps. (CSA C744-04)
- CSA C744-17
CSA C744-17 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2017/CSA-C744-17 entitled Packaged terminal air conditioners and heat pumps. (CSA C744-17)
- packaged terminal heat pump
packaged terminal heat pump means a factory-built packaged heat pump that consists of a separate unencased refrigeration system and uses reverse cycle refrigeration as its primary heat source. (thermopompe terminale autonome)
Marginal note:Energy-using product
200 (1) A packaged terminal heat pump is prescribed as an energy-using product.
Marginal note:Limit
(2) However, for the purposes of sections 4, 5 and 201, a packaged terminal heat pump is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.
Marginal note:Energy efficiency standards
201 (1) The energy efficiency standards set out in column 2 of the table to this section apply to packaged terminal heat pumps that are manufactured during the periods set out in column 3.
Marginal note:Testing standard
(2) A packaged terminal heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a packaged terminal heat pump as defined in section 199.
Column 1 Column 2 Column 3 Item Testing Standard Energy Efficiency Standard Period of Manufacture 1 CSA C744-04 CSA C744-04, Table 2 On or after December 31, 1998 and before September 30, 2012 2 CSA C744-17 CSA C744-17, Table 2 On or after September 30, 2012
Marginal note:Information
202 (1) For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a packaged terminal heat pump:
(a) its cooling capacity, expressed in kilowatts (British thermal units per hour);
(b) its energy efficiency ratio;
(c) its heating capacity, expressed in kilowatts (British thermal units per hour);
(d) its heating coefficient of performance; and
(e) if applicable, identification of the product as a replacement unit.
Marginal note:Standard
(2) The information must be collected in accordance with
(a) CSA C744-04, if the product was manufactured on or after December 31, 1998 and before September 30, 2012; or
(b) CSA C744-17, if the product is manufactured on or after September 30, 2012.
SUBDIVISION ESingle Package Central Heat Pumps
- SOR/2022-265, s. 14
Marginal note:Definitions
203 The following definitions apply in this Subdivision.
- off mode power consumption
off mode power consumption means the power consumption when the unit is connected to mains power but is not providing cooling or heating. (consommation d’énergie en mode arrêt)
- single package central heat pump
single package central heat pump means a single-phase or three-phase air-to-air central heat pump that is a single package unit and that has a cooling or heating capacity of less than 19 kW (65,000 Btu/h), but does not include a single package vertical heat pump. (thermopompe centrale monobloc)
- single package heat pump
single package heat pump[Repealed, SOR/2022-265, s. 15]
- through-the-wall
through-the-wall means, in respect of a single package central heat pump, one that has a cooling capacity less than or equal to 8.79 kW (30,000 Btu/h), that is designed to be installed through an exterior wall and that is manufactured prior to January 1, 2023. (murale)
Marginal note:Energy-using product
204 (1) A single package central heat pump is prescribed as an energy-using product.
Marginal note:Limit
(2) However, for the purposes of sections 4, 5 and 205, a single package central heat pump is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
Marginal note:Energy efficiency standards — single-phase
205 (1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase single package central heat pumps described in column 1 that are manufactured during the periods set out in column 4.
Marginal note:Energy efficiency standards — three-phase
(1.1) The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase single package central heat pumps described in column 1 that are manufactured during the periods set out in column 4.
Marginal note:Testing standard
(2) A single package central heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a single package central heat pump as defined in section 203.
Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Single package central heat pumps, other than those that are through-the-wall or small-duct and high-velocity CSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor
10 C.F.R. Appendix M for off mode power consumption
Seasonal energy efficiency ratio ≥ 14.0
Heating seasonal performance factor (Region V) ≥ 7.0
Off mode power consumption ≤ 33 W
On or after February 3, 1995 and before January 1, 2023 2 Single package central heat pumps that are through-the-wall CSA C656-05 for seasonal energy efficiency ratio and heating seasonal performance factor
10 C.F.R. Appendix M for off mode power consumption
Seasonal energy efficiency ratio ≥ 12.0
Heating seasonal performance factor (Region V) ≥ 6.4
Off mode power consumption ≤ 33 W
On or after February 3, 1995 and before January 1, 2023 3 Single package central heat pumps that are small-duct and high-velocity CSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor
10 C.F.R. Appendix M for off mode power consumption
Seasonal energy efficiency ratio ≥ 12.0
Heating seasonal performance factor (Region V) ≥ 6.3
Off mode power consumption ≤ 30 W
On or after February 3, 1995 and before January 1, 2023 4 Single package central heat pumps, other than those that are space-constrained 10 C.F.R. Appendix M1 Seasonal energy efficiency ratio 2 ≥ 13.4
Heating seasonal performance factor 2 (Region V) ≥ 5.4
Off mode power consumption ≤ 33 W
On or after January 1, 2023 and before January 1, 2025 5 Single package central heat pumps that are space-constrained 10 C.F.R. Appendix M1 Seasonal energy efficiency ratio 2 ≥ 11.9
Heating seasonal performance factor 2 (Region V) ≥ 5.0
Off mode power consumption ≤ 33 W
On or after January 1, 2023 and before January 1, 2025 6 Single package central heat pumps, other than those that are space-constrained 10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F) Seasonal energy efficiency ratio 2 ≥ 13.4
Heating seasonal performance factor 2 (Region V) ≥ 5.4
Off mode power consumption ≤ 33 W
On or after January 1, 2025 7 Single package central heat pumps that are space-constrained 10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F) Seasonal energy efficiency ratio 2 ≥ 11.9
Heating seasonal performance factor 2 (Region V) ≥ 5.0
Off mode power consumption ≤ 33 W
On or after January 1, 2025 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Single package central heat pumps, other than those that are through-the-wall or small-duct and high-velocity CSA C656-14 Seasonal energy efficiency ratio ≥ 14.0
Heating seasonal performance factor (Region V) ≥ 7.0
On or after February 3, 1995 and before January 1, 2023 2 Single package central heat pumps, other than those that are space-constrained CSA C656-14 Seasonal energy efficiency ratio ≥ 14.0
Heating seasonal performance factor (Region V) ≥ 7.0
On or after January 1, 2023 3 Single package central heat pumps that are through-the-wall CSA C656-05 Seasonal energy efficiency ratio ≥ 12.0
Heating seasonal performance factor (Region V) ≥ 6.4
On or after February 3, 1995 and before January 1, 2023 4 Single package central heat pumps that are space-constrained CSA C656-14 Seasonal energy efficiency ratio ≥ 12.0
Heating seasonal performance factor (Region V) ≥ 6.4
On or after January 1, 2023 5 Single package central heat pumps that are small-duct and high-velocity CSA C656-14 Seasonal energy efficiency ratio ≥ 12.0
Heating seasonal performance factor (Region V) ≥ 6.3
On or after February 3, 1995 and before January 1, 2023
- Date modified: