Energy Efficiency Regulations, 2016 (SOR/2016-311)
Full Document:
- HTMLFull Document: Energy Efficiency Regulations, 2016 (Accessibility Buttons available) |
- XMLFull Document: Energy Efficiency Regulations, 2016 [1222 KB] |
- PDFFull Document: Energy Efficiency Regulations, 2016 [4041 KB]
Regulations are current to 2024-11-11 and last amended on 2024-03-27. Previous Versions
PART 2Energy-Using Products (continued)
DIVISION 7Lamps and Lamp Ballasts (continued)
SUBDIVISION BGeneral Service Lamps (continued)
Marginal note:Information
436 For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a general service lamp:
(a) a description of the lamp, collected in accordance with ANSI C78.79;
(b) its colour rendering index, collected in accordance with CIE 13.3;
(c) its correlated colour temperature, collected in accordance with CIE 15;
(d) the following information collected in accordance with IES LM45, with the testing procedure adjusted in accordance with subsection 435(3), namely,
(i) its nominal power, expressed in watts, or if it is a three-way lamp, its nominal power, expressed in watts, at each operating level, and
(ii) its luminous flux, expressed in lumens, or if it is a three-way lamp, its luminous flux, expressed in lumens, at each operating level; and
(e) its life, expressed in hours, collected in accordance with IES LM49, with the testing procedure adjusted in accordance with subsection 435(3).
SUBDIVISION CModified Spectrum Incandescent Lamps
Marginal note:Definition of modified spectrum incandescent lamp
437 (1) In this Subdivision, modified spectrum incandescent lamp means a modified spectrum lamp that has a luminous flux of at least 232 lm but not more than 1 950 lm, a nominal voltage of at least 110 V but not more than 130 V or a nominal voltage range that lies at least partially between those voltages, and a screw base. It does not include any of the following:
(a) an appliance lamp;
(b) a CFL;
(c) an infrared lamp;
(d) a lamp that has a G-shape as specified in ANSI C78.20 and ANSI C78.79 and a diameter of 12.7 cm or more;
(e) a lamp that has a T-shape as specified in ANSI C78.20 and ANSI C78.79 and a maximum nominal power of 40 W or a length of more than 25.4 cm or both;
(f) a lamp that uses solid state technology, namely, a lamp with a light source that comes from light-emitting diodes;
(g) a left-hand thread lamp;
(h) a plant lamp;
(i) an incandescent reflector lamp that has a shape specified in ANSI C78.79;
(j) a vacuum type or gas-filled lamp that has a sufficiently low bulb temperature to permit exposed outdoor use on high-speed flashing circuits and that is marketed as a sign service lamp;
(k) a silver bowl lamp;
(l) a traffic signal module, a pedestrian module or a street light;
(m) a submersible lamp;
(n) a lamp that has a screw base size of E5, E10, E11, E12, E17, E26/50×39, E26/53×39, E29/28, E29/53×39, E39, E39d, EP39 or EX39 as specified in ANSI C81.61; and
(o) a lamp that has a B, BA, CA, F, G16-½, G25, G30, S or M-14 shape or other similar shape as specified in ANSI C78.20 and ANSI C78.79 and a maximum nominal power of 40 W.
Marginal note:Luminous flux
(2) For the purposes of these Regulations, the luminous flux of a modified spectrum incandescent lamp must be calculated in accordance with IES LM45, except that the lamp must be tested at 120 V regardless of its nominal voltage.
Marginal note:Energy-using product
438 (1) A modified spectrum incandescent lamp is prescribed as an energy-using product.
Marginal note:Limits
(2) However, a modified spectrum incandescent lamp is not considered to be an energy-using product
(a) for the purposes of sections 4 and 439,
(i) if it is a rough service lamp, a vibration service lamp, a shatter-resistant lamp or a lamp with an E26d screw base,
(ii) if it has a luminous flux of at least 788 lm and was manufactured before January 1, 2014, or
(iii) if it has a luminous flux of less than 788 lm and was manufactured before December 31, 2014; and
(b) for the purposes of sections 5 and 425 to 429, if it was manufactured before September 1, 2008.
Marginal note:Energy efficiency standards
439 (1) The energy efficiency standards set out in column 2 of the table to this section apply to modified spectrum incandescent lamps described in column 1 that are manufactured during the periods set out in column 3.
Marginal note:Testing standard
(2) A modified spectrum incandescent lamp complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures that are applicable to a modified spectrum incandescent lamp as defined in section 437 and set out in the following standards:
(a) IES LM45 for the nominal power;
(b) IES LM49 for the life of the product; and
(c) CIE 13.3 for the colour rendering index.
Marginal note:Adjusted testing procedure
(3) The testing referred to in subsection (2) must, despite any provision to the contrary in the identified standard, be conducted with the lamp operating at 120 V regardless of its nominal voltage.
Column 1 Column 2 Column 3 Item Energy-using Product Energy Efficiency Standard Period of Manufacture 1 Modified spectrum incandescent lamps that have a luminous flux of < 563 lm Nominal power ≤ 29 W
Life ≥ 1 000 hours
Colour rendering index ≥ 75
On or after December 31, 2014 2 Modified spectrum incandescent lamps that have a luminous flux of ≥ 563 lm and < 788 lm Nominal power ≤ 43 W
Life ≥ 1 000 hours
Colour rendering index ≥ 75
On or after December 31, 2014 3 Modified spectrum incandescent lamps that have a luminous flux of ≥ 788 lm and < 1 118 lm Nominal power ≤ 53 W
Life ≥ 1 000 hours
Colour rendering index ≥ 75
On or after January 1, 2014 4 Modified spectrum incandescent lamps that have a luminous flux of ≥ 1 118 lm Nominal power ≤ 72 W
Life ≥ 1 000 hours
Colour rendering index ≥ 75
On or after January 1, 2014
Marginal note:Information
440 For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a modified spectrum incandescent lamp:
(a) a description of the lamp, collected in accordance with ANSI C78.79;
(b) its colour rendering index, collected in accordance with CIE 13.3;
(c) its correlated colour temperature, collected in accordance with CIE 15;
(d) the following information collected in accordance with IES LM45, with the testing procedure adjusted in accordance with subsection 439(3), namely,
(i) its nominal power, expressed in watts, or if it is a three-way lamp, its nominal power, expressed in watts, at each operating level, and
(ii) its luminous flux, expressed in lumens, or if it is a three-way lamp, its luminous flux, expressed in lumens, at each operating level; and
(e) its life, expressed in hours, collected in accordance with IES LM49, with the testing procedure adjusted in accordance with subsection 439(3).
SUBDIVISION DGeneral Service Incandescent Reflector Lamps
Marginal note:Definitions
441 The following definitions apply in this Subdivision.
- CSA C862-01
CSA C862-01 means the CSA standard CAN/CSA-C862-01 entitled Performance of Incandescent Reflector Lamps. (CSA C862-01)
- CSA C862-09
CSA C862-09 means the CSA standard CAN/CSA-C862-09 entitled Performance of Incandescent Reflector Lamps. (CSA C862-09)
- CSA C862-12
CSA C862-12 means the CSA standard CAN/CSA-C862-12 entitled Performance of incandescent reflector lamps. (CSA C862-12)
- general service incandescent reflector lamp
general service incandescent reflector lamp means an incandescent reflector lamp that has a bulb shape described in ANSI C78.79 or a bulb shape similar to that shape, and that has an E26/24 single contact or E26/50×39 skirted medium screw base, a nominal voltage of at least 100 V but not more than 130 V or a nominal voltage range that lies at least partially between those voltages, a diameter of more than 57 mm and a nominal power of at least 40 W but not more than 205 W. It does not include any of the following:
(a) a coloured lamp;
(b) a rough service lamp;
(c) a vibration service lamp;
(d) a BR30 or BR40 lamp that has a nominal power of 50 W or less or of 65 W;
(e) an R20 lamp that
(i) has a nominal power of 45 W or less, or
(ii) has a nominal power of 100 W and a nominal overall length of not more than 92 mm (3.625 inches) and is designed and marketed for pool and spa applications; or
(f) a modified spectrum lamp that
(i) is an ER30 or ER40 lamp, that has a nominal power of 50 W or less,
(ii) is an ER40 lamp that has a nominal power of 65 W, or
(iii) was manufactured before July 15, 2012. (lampe-réflecteur à incandescence standard)
Marginal note:Energy-using product
442 (1) A general service incandescent reflector lamp is prescribed as an energy-using product.
Marginal note:Limits
(2) However, a general service incandescent reflector lamp is not considered to be an energy-using product
(a) for the purpose of section 4, if it was manufactured before December 31, 1996; and
(b) for the purposes of sections 425 to 429, if it was manufactured before September 1, 2008.
Marginal note:Energy efficiency standards
443 (1) The energy efficiency standards set out in column 2 of the table to this section apply to general service incandescent reflector lamps described in column 1 that are manufactured during the periods set out in column 3.
Marginal note:Testing standard
(2) A general service incandescent reflector lamp complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C862-12 that are applicable to a general service incandescent reflector lamp as defined in section 441.
Column 1 Column 2 Column 3 Item Energy-using Product Energy Efficiency Standard Period of Manufacture 1 General service incandescent reflector lamps CSA C862-01, Tables 1 and 2 Before June 1, 2009 2 General service incandescent reflector lamps that are ER30 or ER40 lamps with a nominal power of 50 W 7.0 lm/W On or after June 1, 2009 3 General service incandescent reflector lamps that are ER30 or ER40 lamps with a nominal power of < 50 W 10.5 lm/W On or after June 1, 2009 4 General service incandescent reflector lamps that are ER40 lamps with a nominal power of 65 W 12.5 lm/W On or after June 1, 2009 5 General service incandescent reflector lamps, other than ER30 or ER40 lamps with a nominal power of ≤ 50 W and ER40 lamps with a nominal power of 65 W CSA C862-09, Table 1 On or after June 1, 2009 and before July 15, 2012 6 General service incandescent reflector lamps, other than ER30 or ER40 lamps with a nominal power of ≤ 50 W and ER40 lamps with a nominal power of 65 W CSA C862-12, Table 1 On or after July 15, 2012
- Date modified: