Government of Canada / Gouvernement du Canada
Symbol of the Government of Canada

Search

Energy Efficiency Regulations, 2016

Version of section 372 from 2019-12-12 to 2023-06-20:


Marginal note:Energy efficiency standards

  •  (1) The energy efficiency standards set out in column 2 of the table to this section apply to electric water heaters described in column 1.

  • Marginal note:Testing standard

    (2) An electric water heater described in column 1 complies with the energy efficiency standard set out in column 3 if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to an electric water heater as defined in section 370.

    TABLE

    ItemColumn 1Column 2Column 3
    Energy-using ProductStandardEnergy Efficiency Standard
    1Household electric water heaters that have a bottom inlet and a Vr of ≥ 50 L but ≤ 270 LCSA C191-04Standby loss, in W, ≤ 40 + 0.2 Vr
    2Household electric water heaters that have a bottom inlet and a Vr of > 270 L but ≤ 454 LCSA C191-04Standby loss, in W, ≤ 0.472 Vr - 33.5
    3Household electric water heaters that have a top inlet and a Vr of ≥ 50 L but ≤ 270 LCSA C191-04Standby loss, in W, ≤ 35 + 0.2 Vr
    4Household electric water heaters that have a top inlet and a Vr of > 270 L but ≤ 454 LCSA C191-04Standby loss, in W, ≤ 0.472 Vr - 38.5
    5Commercial electric water heaters10 C.F.R. Appendix BStandby loss, in %/hr ≤ 0.3 + 102.2/Vs
  • SOR/2019-164, s. 28

Date modified: