Energy Efficiency Regulations, 2016
Version of section 372 from 2017-06-28 to 2019-12-11:
Marginal note:Energy efficiency standards
372 (1) The energy efficiency standards set out in column 2 of the table to this section apply to electric water heaters described in column 1.
Marginal note:Testing standard
(2) An electric water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C191-04 that are applicable to an electric water heater as defined in section 370.
Column 1 Column 2 Item Energy-using Product Energy Efficiency Standard 1 Electric water heaters that have a bottom inlet and a Vr of ≥ 50 L but ≤ 270 L Standby loss, in W, ≤ 40 + 0.2 Vr 2 Electric water heaters that have a bottom inlet and a Vr of > 270 L but ≤ 454 L Standby loss, in W, ≤ 0.472 Vr - 33.5 3 Electric water heaters that have a top inlet and a Vr of ≥ 50 L but ≤ 270 L Standby loss, in W, ≤ 35 + 0.2 Vr 4 Electric water heaters that have a top inlet and a Vr of > 270 L but ≤ 454 L Standby loss, in W, ≤ 0.472 Vr- 38.5
- Date modified: