Government of Canada / Gouvernement du Canada
Symbol of the Government of Canada

Search

Energy Efficiency Regulations, 2016

Version of section 205 from 2022-12-21 to 2024-06-11:


Marginal note:Energy efficiency standards — single-phase

  •  (1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase single package central heat pumps described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Energy efficiency standards — three-phase

    (1.1) The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase single package central heat pumps described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Testing standard

    (2) A single package central heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a single package central heat pump as defined in section 203.

    TABLE 1

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture
    1Single package central heat pumps, other than those that are through-the-wall or small-duct and high-velocity

    CSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor

    10 C.F.R. Appendix M for off mode power consumption

    Seasonal energy efficiency ratio ≥ 14.0

    Heating seasonal performance factor (Region V) ≥ 7.0

    Off mode power consumption ≤ 33 W

    On or after February 3, 1995 and before January 1, 2023
    2Single package central heat pumps that are through-the-wall

    CSA C656-05 for seasonal energy efficiency ratio and heating seasonal performance factor

    10 C.F.R. Appendix M for off mode power consumption

    Seasonal energy efficiency ratio ≥ 12.0

    Heating seasonal performance factor (Region V) ≥ 6.4

    Off mode power consumption ≤ 33 W

    On or after February 3, 1995 and before January 1, 2023
    3Single package central heat pumps that are small-duct and high-velocity

    CSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor

    10 C.F.R. Appendix M for off mode power consumption

    Seasonal energy efficiency ratio ≥ 12.0

    Heating seasonal performance factor (Region V) ≥ 6.3

    Off mode power consumption ≤ 30 W

    On or after February 3, 1995 and before January 1, 2023
    4Single package central heat pumps, other than those that are space-constrained10 C.F.R. Appendix M1

    Seasonal energy efficiency ratio 2 ≥ 13.4

    Heating seasonal performance factor 2 (Region V) ≥ 5.4

    Off mode power consumption ≤ 33 W

    On or after January 1, 2023 and before January 1, 2025
    5Single package central heat pumps that are space-constrained10 C.F.R. Appendix M1

    Seasonal energy efficiency ratio 2 ≥ 11.9

    Heating seasonal performance factor 2 (Region V) ≥ 5.0

    Off mode power consumption ≤ 33 W

    On or after January 1, 2023 and before January 1, 2025
    6Single package central heat pumps, other than those that are space-constrained10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F)

    Seasonal energy efficiency ratio 2 ≥ 13.4

    Heating seasonal performance factor 2 (Region V) ≥ 5.4

    Off mode power consumption ≤ 33 W

    On or after January 1, 2025
    7Single package central heat pumps that are space-constrained10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F)

    Seasonal energy efficiency ratio 2 ≥ 11.9

    Heating seasonal performance factor 2 (Region V) ≥ 5.0

    Off mode power consumption ≤ 33 W

    On or after January 1, 2025

    TABLE 2

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture
    1Single package central heat pumps, other than those that are through-the-wall or small-duct and high-velocityCSA C656-14

    Seasonal energy efficiency ratio ≥ 14.0

    Heating seasonal performance factor (Region V) ≥ 7.0

    On or after February 3, 1995 and before January 1, 2023
    2Single package central heat pumps, other than those that are space-constrainedCSA C656-14

    Seasonal energy efficiency ratio ≥ 14.0

    Heating seasonal performance factor (Region V) ≥ 7.0

    On or after January 1, 2023
    3Single package central heat pumps that are through-the-wallCSA C656-05

    Seasonal energy efficiency ratio ≥ 12.0

    Heating seasonal performance factor (Region V) ≥ 6.4

    On or after February 3, 1995 and before January 1, 2023
    4Single package central heat pumps that are space-constrainedCSA C656-14

    Seasonal energy efficiency ratio ≥ 12.0

    Heating seasonal performance factor (Region V) ≥ 6.4

    On or after January 1, 2023
    5Single package central heat pumps that are small-duct and high-velocityCSA C656-14

    Seasonal energy efficiency ratio ≥ 12.0

    Heating seasonal performance factor (Region V) ≥ 6.3

    On or after February 3, 1995 and before January 1, 2023
  • SOR/2019-163, s. 36
  • SOR/2022-265, s. 17

Date modified: