Government of Canada / Gouvernement du Canada
Symbol of the Government of Canada

Search

Energy Efficiency Regulations, 2016

Version of section 205 from 2019-12-12 to 2022-12-20:


Marginal note:Energy efficiency standards — single-phase

  •  (1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase package heat pumps described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Energy efficiency standards — three-phase

    (1.1) The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase single package heat pumps described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Testing standard

    (2) A single package heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a single package heat pump as defined in section 203.

    TABLE 1

    ItemColumn 1Column 2Column 3Column 4
    Energy-using ProductStandardEnergy Efficiency StandardPeriod of Manufacture
    1Single package heat pumps, other than those that are through-the-wall or small-duct and high-velocityCSA C656-05

    Seasonal energy efficiency ratio ≥ 13.0

    Heating seasonal performance factor (Region V) ≥ 6.7

    On or after February 3, 1995 and before January 1, 2017
    2Single package heat pumps, other than those that are through-the-wall or small-duct and high-velocity

    CSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor

    10 C.F.R. Appendix M for off mode power consumption

    Seasonal energy efficiency ratio ≥ 14.0

    Heating seasonal performance factor (Region V) ≥ 7.0

    Off mode power consumption ≤ 33 W

    On or after January 1, 2017
    3Single package heat pumps that are through-the-wallCSA C656-05

    Seasonal energy efficiency ratio ≥ 10.6

    Heating seasonal performance factor (Region V) ≥ 6.1

    On or after February 3, 1995 and before January 23, 2010
    4Single package heat pumps that are through-the-wallCSA C656-05

    Seasonal energy efficiency ratio ≥ 12.0

    Heating seasonal performance factor (Region V) ≥ 6.4

    On or after January 23, 2010 and before January 1, 2017
    5Single package heat pumps that are through-the-wall

    CSA C656-05 for seasonal energy efficiency ratio and heating seasonal performance factor

    10 C.F.R. Appendix M for off mode power consumption

    Seasonal energy efficiency ratio ≥ 12.0

    Heating seasonal performance factor (Region V) ≥ 6.4

    Off mode power consumption ≤ 33 W

    On or after January 1, 2017
    6Single package heat pumps that are small-duct and high-velocityCSA C656-05

    Seasonal energy efficiency ratio ≥ 13.0

    Heating seasonal performance factor (Region V) ≥ 6.7

    On or after February 3, 1995 and before January 1, 2017
    7Single package heat pumps that are small-duct and high-velocity

    CSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor

    10 C.F.R. Appendix M for off mode power consumption

    Seasonal energy efficiency ratio ≥ 12.0

    Heating seasonal performance factor (Region V) ≥ 6.3

    Off mode power consumption ≤ 30 W

    On or after January 1, 2017

    TABLE 2

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductStandardEnergy Efficiency StandardPeriod of Manufacture
    1Single package heat pumps, other than those that are through-the-wall or small-duct and high-velocityCSA C656-05

    Seasonal energy efficiency ratio ≥ 13.0

    Heating seasonal performance factor (Region V) ≥ 6.7

    On or after February 3, 1995 and before January 1, 2017
    2Single package heat pumps, other than those that are through-the-wall or small-duct and high-velocityCSA C656-14

    Seasonal energy efficiency ratio ≥ 14.0

    Heating seasonal performance factor (Region V) ≥ 7.0

    On or after January 1, 2017
    3Single package heat pumps that are through-the-wallCSA C656-05

    Seasonal energy efficiency ratio ≥ 10.6

    Heating seasonal performance factor (Region V) ≥ 6.1

    On or after February 3, 1995 and before January 23, 2010
    4Single package heat pumps that are through-the-wallCSA C656-05

    Seasonal energy efficiency ratio ≥ 12.0

    Heating seasonal performance factor (Region V) ≥ 6.4

    On or after January 23, 2010
    5Single package heat pumps that are small-duct and high-velocityCSA C656-05

    Seasonal energy efficiency ratio ≥ 13.0

    Heating seasonal performance factor (Region V) ≥ 6.7

    On or after February 3, 1995 and before January 1, 2017
    6Single package heat pumps that are small-duct and high-velocityCSA C656-14

    Seasonal energy efficiency ratio ≥ 12.0

    Heating seasonal performance factor (Region V) ≥ 6.3

    On or after January 1, 2017
  • SOR/2019-163, s. 36

Date modified: