Marginal note:Energy efficiency standards

  •  (1) The energy efficiency standards set out in column 3 of the table to this section apply to commercial refrigerator-freezers described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Testing standard

    (2) A commercial refrigerator-freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a commercial refrigerator-freezer as defined in section 636.

    TABLE

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductStandardEnergy Efficiency StandardPeriod of Manufacture
    1Commercial refrigerator-freezers that are self-contained, closed and not transparentCSA C657, Test Procedure AEdaily ≤ 0.00964 AV + 2.63On or after April 1, 2007 and before January 1, 2008
    2Commercial refrigerator-freezers that are self-contained, closed and not transparentCSA C657, Test Procedure AEdaily ≤ 0.00964 AV + 1.65On or after January 1, 2008 and before January 1, 2010
    3Commercial refrigerator-freezers that are self-contained, closed and not transparentCSA C657, Test Procedure AEdaily ≤ the greater of (0.00953 AV – 0.71) and 0.70On or after January 1, 2010 and before March 27, 2017
    4Commercial refrigerator-freezers that are self-contained and open or transparentCSA C657, Test Procedure ACSA C657, Table 5On or after January 1, 2012 and before March 27, 2017
    5Commercial refrigerator-freezers that are remote-condensingCSA C657, Test Procedure ACSA C657, Table 5On or after January 1, 2012 and before March 27, 2017
    6Commercial refrigerator-freezersCSA C657, Test Procedure BCSA C657, Table 6On or after March 27, 2017