Government of Canada / Gouvernement du Canada
Symbol of the Government of Canada

Search

Energy Efficiency Regulations, 2016

Version of section 49 from 2017-06-28 to 2019-12-11:


Marginal note:Energy efficiency standards

  •  (1) The energy efficiency standards set out in column 3 of the table to this section apply to freezers described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Testing standard

    (2) A freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a freezer as defined in section 45.

    TABLE

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductStandardEnergy Efficiency StandardPeriod of Manufacture
    1Freezers other than Type 10A chest freezersCSA C300-00CSA C300-00, Table 1, column BOn or after February 3, 1995 and before January 1, 2008
    2Type 10A chest freezersCSA C300-00Annual energy consumption ≤ (0.52 × adjusted volume) + 211.5On or after December 31, 2003 and before January 1, 2008
    3FreezersCSA C300-12CSA C300-12, Table 1On or after January 1, 2008 and before September 15, 2014
    4FreezersCSA C300-15CSA C300-15, Table 1On or after September 15, 2014

Date modified: