Energy Efficiency Regulations, 2016
Version of section 385 from 2019-12-12 to 2023-06-20:
Marginal note:Energy efficiency standards
385 (1) The energy efficiency standards set out in column 3 of the table to this section apply to gas-fired instantaneous water heaters described in column 1 that are manufactured during the period set out in column 4.
Marginal note:Testing standards
(2) A gas-fired instantaneous water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a gas-fired instantaneous water heater as defined in section 382.
Item Column 1 Column 2 Column 3 Column 4 Energy-using Product Standard Energy Efficiency Standard Manufacturing Period 1 Household gas-fired instantaneous water heaters that have a maximum flow rate of < 6.4 L/min CSA P.3-15 Uniform energy factor ≥ 0.86 On or after January 1, 2020 2 Household gas-fired instantaneous water heaters that have a maximum flow rate of ≥ 6.4 L/min CSA P.3-15 Uniform energy factor ≥ 0.87 On or after January 1, 2020 3 Commercial gas-fired instantaneous water heaters 10 C.F.R. Appendix C Thermal efficiency ≥ 94% On or after July 1, 2023
- SOR/2019-164, s. 40
- Date modified: