Energy Efficiency Regulations, 2016

Version of section 377 from 2019-12-12 to 2023-06-20:


 For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas-fired storage water heater described in column 1.

TABLE

ItemColumn 1Column 2Column 3
Energy-using ProductStandardInformation
1Household gas-fired storage water heaters that are manufactured on or after February 3, 1995 and before January 1, 2018CSA P.3-04
  • (a) input rate, in kW (Btu/h);

  • (b) recovery efficiency;

  • (c) type of fuel used;

  • (d) annual energy consumption, in kJ;

  • (e) first-hour rating, in L;

  • (f) Vr; and

  • (g) energy factor.

2Household gas-fired storage water heaters that are manufactured on or after January 1, 2018

CSA P.3-04, if a certification body has verified that product is in compliance with energy efficiency standard set out in any of paragraphs 3(a), 4(a), 5(a) and 6(a) of Table 1 to section 376;

CSA P.3-15, if a certification body has verified that product is in compliance with energy efficiency standard set out in any of paragraphs 3(b), 4(b), 5(b) and 6(b) of Table 1 to section 376.

  • (a) input rate, in kW (Btu/h);

  • (b) recovery efficiency;

  • (c) type of fuel used;

  • (d) annual energy consumption, in kJ;

  • (e) first-hour rating, in L;

  • (f) Vr;

  • (g) energy factor, if a certification body has verified that product is in compliance with the energy efficiency standard set out in any of paragraphs 3(a), 4(a), 5(a) and 6(a) of Table 1 to section 376; and

  • (h) uniform energy factor and Vs, if a certification body has verified that product is in compliance with the energy efficiency standard set out in any of paragraphs 3(b), 4(b), 5(b) and 6(b) of Table 1 to section 376.

3Commercial gas-fired storage water heaters, that have an input rate of > 21.97 kW (75,000 Btu/h) but ≤ 30.5 kW (105,000 Btu/h), have a Vr of ≤ 454 L (120 US gallons), use single-phase power, limit water temperatures to < 82°C (180°F) and are manufactured on or after July 1, 202310 C.F.R. Appendix A
  • (a) uniform energy factor;

  • (b) Vr;

  • (c) Vs;

  • (d) input rate, in kW (Btu/h);

  • (e) the type of fuel used; and

  • (f) information that indicates whether product is a replacement unit.

4Commercial gas-fired storage water heaters, other than those described in item 3, that are manufactured on or after July 1, 202310 C.F.R. Appendix A
  • (a) thermal efficiency;

  • (b) standby loss, in W;

  • (c) Vr;

  • (d) Vs;

  • (e) input rate, in kW (Btu/h);

  • (f) the type of fuel used; and

  • (g) information that indicates whether product is a replacement unit.

  • SOR/2018-201, s. 40
  • SOR/2019-164, s. 34

Date modified: