Energy Efficiency Regulations, 2016

Version of section 376 from 2018-10-31 to 2019-12-11:


Marginal note:Energy efficiency standards

  •  (1) The energy efficiency standards set out in column 3 of the table to this section apply to gas-fired storage water heaters described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Testing standard

    (2) A gas-fired storage water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a gas-fired storage water heater as defined in section 374.

    TABLE

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductStandardEnergy Efficiency StandardPeriod of Manufacture
    1Gas-fired storage water heatersCSA P.3-04Energy factor of ≥ 0.67 – 0.0005 VrOn or after February 3, 1995 and before December 31, 2016
    2Gas-fired storage water heatersCSA P.3-04Energy factor of ≥ 0.675 – 0.00039 VrOn or after December 31, 2016 and before January 1, 2018
    3Gas-fired storage water heaters that have a first-hour rating of < 68 L (18 US gallons)

    CSA P.3-04 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.675 – 0.00039 Vr; or

    • (b) uniform energy factor of ≥ 0.3456 –0.00053 Vs

    On or after January 1, 2018
    4Gas-fired storage water heaters that have a first-hour rating of ≥ 68 L (18 US gallons) but < 193 L (51 US gallons)

    CSA P.3-04 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.675 – 0.00039 Vr; or

    • (b) uniform energy factor of ≥ 0.5982 – 0.00050 Vs.

    On or after January 1, 2018
    5Gas-fired storage water heaters that have a first-hour rating of ≥ 193 L (51 US gallons) but < 284 L (75 US gallons)

    CSA P.3-04 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.675 – 0.00039 Vr; or

    • (b) uniform energy factor of ≥ 0.6483 – 0.00045 Vs.

    On or after January 1, 2018
    6Gas-fired storage water heaters that have a first-hour rating of > 284 L (75 US gallons)

    CSA P.3-04 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.675 – 0.00039 Vr; or

    • (b) uniform energy factor of ≥ 0.692 – 0.00034 Vs.

    On or after January 1, 2018
  • SOR/2018-201, s. 40