Energy Efficiency Regulations, 2016

Version of section 317 from 2016-12-09 to 2017-06-27:

The following provision is not in force.

Marginal note:Energy efficiency standards

  •  (1) The energy efficiency standards set out in column 3 of the table to this section apply to gas boilers described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Testing standard

    (2) A gas boiler complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a gas boiler as defined in section 315.

    TABLE

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductStandardEnergy Efficiency StandardPeriod of Manufacture
    1Gas boilers that are intended for low pressure steam systemsCGA P.2Annual fuel utilization efficiency ≥ 75%On or after December 31, 1998 and before September 1, 2010
    2Gas boilers that are intended for low pressure steam systemsCSA P.2 for annual fuel utilization efficiency

    Annual fuel utilization efficiency ≥ 80%

    No continuously burning pilot light

    On or after September 1, 2010
    3Gas boilers that are intended for hot water systemsCGA P.2Annual fuel utilization efficiency ≥ 80%On or after December 31, 1998 and before September 1, 2010
    4Gas boilers that are intended for hot water systemsCSA P.2 for annual fuel utilization efficiency

    Annual fuel utilization efficiency ≥ 82%

    No continuously burning pilot light

    On or after September 1, 2010 and before September 1, 2012
    5Gas boilers that are intended for hot water systems and have tankless domestic water heating coilsCSA P.2 for annual fuel utilization efficiency

    Annual fuel utilization efficiency ≥ 82%

    No continuously burning pilot light

    On or after September 1, 2012
    6Gas boilers that are intended for hot water systems and do not have tankless domestic water heating coilsCSA P.2 for annual fuel utilization efficiency

    Annual fuel utilization efficiency ≥ 82%

    No continuously burning pilot light

    Equipped with automatic water temperature adjustment device and not operable without the device

    On or after September 1, 2012