Energy Efficiency Regulations, 2016
Marginal note:Information
267 (1) For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a gas fireplace:
(a) the type of fuel it uses;
(b) its maximum and minimum input rates, expressed in kilowatts (British thermal units per hour);
(c) the fireplace efficiency;
(d) information that indicates whether it is freestanding, zero-clearance or an insert;
(e) the type of ignition system it has, namely, standing pilot, intermittent ignition device, on-demand pilot or remotely operated pilot; and
(f) the venting configuration the product has, namely, natural venting, direct venting or powered venting.
Marginal note:Standard
(2) The information must be collected in accordance with
(a) CSA P.4.1, if the product was manufactured on or after June 1, 2003 and before January 1, 2017; or
(b) CSA P.4.1-15, if the product is manufactured on or after January 1, 2017.
- Date modified: