Marginal note:Energy efficiency standards

  •  (1) The energy efficiency standards set out in column 3 of the table to this section apply to split-system heat pumps described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Testing standard

    (2) A split-system heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a split-system heat pump as defined in section 211.

    TABLE

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductStandardEnergy Efficiency StandardPeriod of Manufacture
    1Split-system heat pumps, other than those that are small-duct and high-velocityCSA C656-05

    Seasonal energy efficiency ratio ≥ 13.0

    Heating seasonal performance factor (Region V) ≥ 6.7

    On or after December 31, 1998 and before January 1, 2017
    2Split-system heat pumps, other than those that are small-duct and high-velocityCSA C656-14

    Seasonal energy efficiency ratio ≥ 14.0

    Heating seasonal performance factor (Region V) ≥ 7.1

    On or after January 1, 2017
    3Split-system heat pumps that are small-duct and high-velocityCSA C656-05

    Seasonal energy efficiency ratio ≥ 11.0

    Heating seasonal performance factor (Region V) ≥ 5.9

    On or after December 31, 1998 and before January 1, 2017
    4Split-system heat pumps that are small-duct and high-velocityCSA C656-14

    Seasonal energy efficiency ratio ≥ 12.0

    Heating seasonal performance factor (Region V) ≥ 6.3

    On or after January 1, 2017