Marginal note:Energy efficiency standards

  •  (1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to large heat pumps described in column 1 that are manufactured during the periods set out in column 4 and that have no heating section or have an electric heating section.

  • Marginal note:Energy efficiency standards

    (2) The energy efficiency standards set out in column 3 of Table 2 to this section apply to large heat pumps described in column 1 that are manufactured during the periods set out in column 4 and that have a heating section other than an electric heating section.

  • Marginal note:Testing standard

    (3) A large heat pump complies with the energy efficiency standard set out in column 3 if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a large heat pump as defined in section 195.

    TABLE 1

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductStandardEnergy Efficiency StandardPeriod of Manufacture
    1Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kWCSA C746-98

    Energy efficiency ratio ≥ 10.1

    Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.2 with –8.3°C inlet air

    On or after December 31, 1998 and before January 1, 2010
    2Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW

    CSA C746-06 for energy efficiency ratio and heating coefficient of performance

    AHRI 340/360 for IEER

    Energy efficiency ratio ≥ 11.0

    Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet air

    IEER ≥ 11.2

    On or after January 1, 2010
    3Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kWCSA C746-98

    Energy efficiency ratio ≥ 9.3

    Heating coefficient of performance ≥ 3.1 with 8.3°C inlet air and ≥ 2.0 with –8.3°C inlet air

    On or after December 31, 1998 and before January 1, 2010
    4Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW

    CSA C746-06 for energy efficiency ratio and heating coefficient of performance

    AHRI 340/360 for IEER

    Energy efficiency ratio ≥ 10.6

    Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with –8.3°C inlet air

    IEER ≥ 10.7

    On or after January 1, 2010
    5Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW

    CSA C746-06 for energy efficiency ratio and heating coefficient of performance

    AHRI 340/360 for IEER

    Energy efficiency ratio ≥ 9.5

    Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with –8.3°C inlet air

    IEER ≥ 9.6

    On or after January 1, 2010

    TABLE 2

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductStandardEnergy Efficiency StandardPeriod of Manufacture
    1Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kWCSA C746-98

    Energy efficiency ratio ≥ 9.9

    Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.2 with –8.3°C inlet air

    On or after December 31, 1998 and before January 1, 2010
    2Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW

    CSA C746-06 for energy efficiency ratio and heating coefficient of performance

    AHRI 340/360 for IEER

    Energy efficiency ratio ≥ 10.8

    Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet air

    IEER ≥ 11.0

    On or after January 1, 2010
    3Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kWCSA C746-98

    Energy efficiency ratio ≥ 9.1

    Heating coefficient of performance ≥ 3.1 with 8.3°C inlet air and ≥ 2.0 with –8.3°C inlet air

    On or after December 31, 1998 and before January 1, 2010
    4Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW

    CSA C746-06 for energy efficiency ratio and heating coefficient of performance

    AHRI 340/360 for IEER

    Energy efficiency ratio ≥ 10.4

    Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with –8.3°C inlet air

    IEER ≥ 10.5

    On or after January 1, 2010
    5Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW

    CSA C746-06 for energy efficiency ratio and heating coefficient of performance

    AHRI 340/360 for IEER

    Energy efficiency ratio ≥ 9.3

    Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with –8.3°C inlet air

    IEER ≥ 9.4

    On or after January 1, 2010

Date modified: