Energy Efficiency Regulations, 2016
Version of section 134 from 2016-12-09 to 2017-06-27:
The following provision is not in force.
Marginal note:Energy efficiency standards
134 (1) The energy efficiency standards set out in column 3 of the table to this section apply to split-system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.
Marginal note:Testing standard
(2) A split-system central air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a split-system central air conditioner as defined in section 132.
Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Standard Energy Efficiency Standard Period of Manufacture 1 Split-system central air conditioners, other than those that are small-duct and high-velocity CSA C656-05 Seasonal energy efficiency ratio ≥ 13.0 On or after February 3, 1995 and before January 1, 2017 2 Split-system central air conditioners, other than those that are small-duct and high-velocity CSA C656-14 Seasonal energy efficiency ratio ≥ 13.0 On or after January 1, 2017 3 Split-system central air conditioners that are small-duct and high-velocity CSA C656-05 Seasonal energy efficiency ratio ≥ 11.0 On or after February 3, 1995 and before January 1, 2017 4 Split-system central air conditioners that are small-duct and high-velocity CSA C656-14 Seasonal energy efficiency ratio ≥ 12.0 On or after January 1, 2017