Multi-Sector Air Pollutants Regulations

Version of section 16 from 2025-11-21 to 2026-03-17:


Marginal note:Percentage of methane

  •  (1) The percentage of methane in the gaseous fossil fuel introduced into the combustion chamber of a boiler or heater, for a given hour, must be determined, by volume, as a weighted average by the formula

    [(CH4 ng × Qng) + (CH4 alt × Qalt)] × 100/(Qng + Qalt)

    where

    CH4 ng
    is the concentration of methane, determined in accordance with subsection (2), in the natural gas introduced into the combustion chamber during the given hour, expressed as a decimal fraction;
    Qng
    is the quantity of the natural gas introduced into the combustion chamber during the given hour, as measured by a flow meter on the input, expressed in standard m3;
    CH4 alt
    is the concentration of methane, determined in accordance with subsection (2), in the alternative gas introduced into the combustion chamber during the given hour, expressed as a decimal fraction; and
    Qalt
    is the quantity of the alternative gas introduced into the combustion chamber during the given hour, as measured by a flow meter on the input, expressed in standard m3.
  • Marginal note:Gas introduced into combustion chamber

    (2) The concentration of methane in the gaseous fossil fuel introduced into the combustion chamber is

    • (a) for commercial grade natural gas, either

      • (i) to be determined in accordance with ASTM D1945-03, ASTM D1946-90, GPA 2261-25 or GPA 2286-24 , or

      • (ii) fixed as 95%; and

    • (b) for any other gaseous fossil fuel, to be determined in accordance with ASTM D1945-03, ASTM D1946-90, GPA 2261-25 or GPA 2286-24, whichever applies.

  • SOR/2025-229, s. 4