Explosives Regulations, 2013

Version of section 382 from 2013-11-27 to 2014-01-31:

The following provision is not in force.

Marginal note:Storage requirements — dwelling

  •  (1) When special effect pyrotechnics are stored in a dwelling, they must be stored away from flammable substances and sources of ignition, in a manner that protects them from theft and ensures that access to them is limited to people authorized by the user.

  • Marginal note:Storage requirements — storage unit

    (2) When special effect pyrotechnics are stored in a Footnote *storage unit,

    • (a) the storage unit must be located in a dry place, away from flammable substances and sources of ignition;

    • (b) the storage unit must be constructed and maintained to prevent unauthorized access and to protect the contents from weather;

    • (c) if the storage unit is a container, it must not impede exit in case of fire;

    • (d) if the storage unit is not a container, all exits must be kept unobstructed;

    • (e) any shelving in the storage unit must be made from a non-sparking material (for example, wood or painted metal);

    • (f) nothing other than special effect pyrotechnics may be stored in the storage unit;

    • (g) propellant powder, firework accessories and other special effect pyrotechnics must be stored separately from one another (for example, on different shelves or separated by a wooden partition);

    • (h) the storage unit must be Footnote *attended when it is unlocked;

    • (i) the storage unit must be kept clean, dry, organized and free of grit;

    • (j) any spill, leakage or other contamination in the storage unit must be cleaned up immediately;

    • (k) precautions that minimize the likelihood of fire in or near the storage unit must be taken; and

    • (l) a sign that displays the words “Danger — Fire Hazard/Risque d’incendie” in letters at least 10 cm high and that prohibits smoking using letters, or a symbol, at least 10 cm high must be posted on the storage unit in a clearly visible location.


Date modified: