Government of Canada / Gouvernement du Canada
Symbol of the Government of Canada

Search

Weights and Measures Regulations

Version of section 181 from 2006-03-22 to 2017-02-12:


 When a machine that is of the self-indicating or semi-self-indicating type is tested by

  • (a) the removal of a known test load, in the case of a machine that is normally used for weighing following the addition of load, or

  • (b) the addition of a known test load, in the case of a machine that is normally used for weighing following the subtraction of load,

the acceptance and in-service limits of error are 1.5 times the limits of error set out in the tables to sections 176 and 177 and set out in sections 188 and 192.

  • SOR/89-570, s. 6(F)

Date modified: