181 When a machine that is of the self-indicating or semi-self-indicating type is tested by
(a) the removal of a known test load, in the case of a machine that is normally used for weighing following the addition of load, or
(b) the addition of a known test load, in the case of a machine that is normally used for weighing following the subtraction of load,
the acceptance and in-service limits of error are 1.5 times the limits of error set out in the tables to sections 176 and 177 and set out in sections 188 and 192.
- SOR/89-570, s. 6(F)