Weights and Measures Regulations
C.R.C., c. 1605
Regulations Respecting Weights and Measures
Short Title
1 These Regulations may be cited as the Weights and Measures Regulations.
Interpretation
2 In these Regulations,
- acceptance limits of error
acceptance limits of error means the limits of error that apply to a device when the performance of the device is tested
(a) at the time the class, type or design of that device is examined for approval,
(b) at the time the device is inspected prior to its first use in trade,
(c) at the time the measuring elements of the device are overhauled or repaired following the failure of the device on inspection to measure within the applicable limits of error, or
(d) at any time within 30 days after the time referred to in paragraph (b) or (c); (marge de tolérance à l’acceptation)
- Act
Act means the Weights and Measures Act; (Loi)
- automatic weighing device
automatic weighing device [Repealed, SOR/2005-130, s. 1]
- Canadian unit
Canadian unit means a unit of measurement set out in Schedule II to the Act; (unité canadienne)
- height
height means, with respect to the height of a letter, the height of an upper case letter where words appear in upper case and the height of the lower case letter “o” where words appear in lower case or in a mixture of upper and lower case; (hauteur)
- in-service limits of error
in-service limits of error means the limits of error that apply to a device when the performance of the device is tested at any time other than a time referred to in the definition of acceptance limits of error; (marge de tolérance en service)
- inspection mark
inspection mark means a mark that is made by an inspector after an inspection of a device and that consists of a symbol for the time being in use by inspectors and the date of inspection; (marque de vérification)
- Measurement Canada office
Measurement Canada office means any office of the Department of Industry for use by persons employed in the administration of the Act; (bureau de Mesures Canada)
- metric unit
metric unit means a unit of measurement set out in Schedule I to the Act; (unité métrique)
- non-automatic weighing device
non-automatic weighing device [Repealed, SOR/2005-130, s. 1]
- packing device
packing device means a device that, as part of a mechanical packaging system, measures a predetermined quantity of commodity without recording the measurement of each quantity of commodity measured by the device or without being operated by a person who observes or records the measurement of each quantity of commodity measured by the device; (instrument d’emballage)
- previous enactment
previous enactment means any Act of Parliament relating to weights and measures, and any regulations made under that Act, enacted prior to the Weights and Measures Act, S.C. 1970-71-72, c. 36; (texte législatif antérieur)
- standard quantity commodity
standard quantity commodity means a commodity that is part of a lot made up of the same commodity, with identical net quantity statements; (marchandise à quantité standard)
- tank
tank means a measuring tank for use in trade for measuring the volume of liquid received or delivered, and includes a fixed, portable and vehicle-mounted measuring tank; (réservoir)
- weights and measures office
weights and measures office [Repealed, SOR/2005-297, s. 1]
- SOR/89-570, s. 6(F)
- SOR/90-118, s. 1
- SOR/93-234, s. 2
- SOR/98-115, s. 1
- SOR/2005-130, s. 1
- SOR/2005-297, ss. 1, 41(F)
PART IDevices
Exemptions from the Act
3 A class, type or design of device is exempt from the Act where the class, type or design is
(a) subject to verification pursuant to the Electricity and Gas Inspection Act; or
(b) designed for use and used only in laboratories or in scientific study and not approved pursuant to section 3 of the Act.
- SOR/80-429, s. 1
- SOR/93-234, s. 2
Exemptions from Section 8 of the Act
4 (1) The following classes or types of devices are exempt from section 8 of the Act:
(a) water meters;
(b) parking meters;
(c) taxi meters;
(d) odometers of motor vehicles;
(e) coin-operated machines for weighing persons;
(f) coin-operated machines that dispense a predetermined quantity of liquid into a container and that do not register by a mechanical or an electrical indicator the quantity of liquid dispensed;
(g) clocks, watches, chronometers and other time measuring devices;
(h) milk measuring tanks for farm use;
(i) measuring tanks mounted on railway cars;
(j) tanks that have a capacity in excess of 55 000 L or 12,000 gallons;
(k) meters for the measurement of grease and other commodities having flow properties similar to grease;
(l) static measures that are used as containers in which a commodity is sold or offered for sale;
(m) packing devices; and
(n) weighing machines designed for use in laboratories, scientific study or weighing precious metals and that are used for weighing precious metals or other commodities of comparable value, if they conform to applicable specifications for performance, installation and use established by these Regulations and if, prior to December 31, 1981, they are inspected and certified as meeting such specifications.
(2) A device used exclusively to weigh or measure standard quantity commodities is exempt from section 8 of the Act.
- SOR/80-429, s. 2
- SOR/90-118, s. 3
- SOR/93-234, s. 2(F)
- SOR/2005-297, ss. 2, 41(F)
Exemptions from Paragraphs 8(b) and 26(1)(c) of the Act
5 (1) Subject to subsection (2), a meter register approved pursuant to section 3 of the Act that has no means, or has means that are not in use, of automatic temperature, pressure or density compensation is exempt from paragraphs 8(b) and 26(1)(c) of the Act if it is installed as a replacement register on a volumetric liquid meter that has previously been inspected and certified pursuant to paragraph 8(b) of the Act.
(2) Where a register described in subsection (1) is altered to operate with automatic temperature, pressure or density compensation, the register shall be inspected and certified pursuant to paragraphs 8(b) and 26(1)(c) of the Act.
- SOR/90-118, s. 4
Exemption from Paragraph 8(a) of the Act
6 A tank is exempt from paragraph 8(a) of the Act if it conforms to applicable specifications relating to design, composition, construction and performance set out in Divisions I,V, X and XII of Part V and any additional specifications established pursuant to section 13.
- SOR/90-118, s. 4
Exemptions from Sections 8, 23 and 33 of the Act and Paragraph 24(b) of the Act
7 (1) Subject to subsection (2), where the parties to an intended trade transaction give written notice to the Minister that
(a) a device approved for use in trade or approved for use in the particular manner or for the particular purpose contemplated by the parties (hereinafter referred to as an “approved device”) is not available to the parties for use in their intended trade transaction,
(b) the parties wish to use in their intended trade transaction a device that is not an approved device, and
(c) it would be impractical or unreasonably expensive to obtain approval for the class, type or design of device that the parties wish to use in their intended trade transaction or to comply with the inspection required by paragraph 8(b) of the Act,
the trade transaction is exempt from sections 8, 23 and 33 of the Act and paragraph 24(b) of the Act.
(2) A trade transaction referred to in subsection (1) is not exempt from the provisions of the Act referred to in that subsection unless
(a) the parties referred to in subsection (1) furnish to the Minister such information as the Minister requires relating to the device that the parties wish to use;
(b) the device that the parties wish to use conforms to all requirements of the Act and these Regulations, except the specifications relating to design, composition, construction and performance;
(c) the parties have entered into a written contract not exceeding three years in duration respecting the use of the device that the parties wish to use in the intended trade transaction showing
(i) the limits of error applicable to the device and to the commodities to be measured by the device,
(ii) the means to be used for calibrating the device, and
(iii) the intervals at which that device will be calibrated;
(d) the parties have forwarded to the Minister a true copy of the part of the contract dealing with the use of the device; and
(e) the device that the parties wish to use measures within the limits of error referred to in subparagraph (c)(i).
- SOR/89-570, s. 6(F)
- SOR/2005-297, s. 41(F)
Exemptions from Approval
8 (1) Subject to section 10, a device that has been inspected and certified under a previous enactment but not approved pursuant to section 3 of the Act is exempt from paragraph 8(a) of the Act.
(2) Subject to section 10, a device or class, type or design of device that has been approved for use in trade under a previous enactment is exempt from paragraph 8(a) of the Act.
- SOR/90-118, s. 5
9 (1) Subject to subsection (2), where a device or class, type or design of device approved pursuant to subsection 3(1) of the Act or under a previous enactment, or a device inspected and certified by an inspector on or before December 31, 1989, is altered to measure in terms of any units of measurement set out and defined in Schedule I of the Act, the device or class, type or design of device is exempt from paragraph 8(a) of the Act if the device or class, type or design of device as altered conforms to
(a) applicable specifications relating to design, composition, construction and performance set out in Part V and any additional specifications established pursuant to section 13; or
(b) applicable specifications relating to design, composition, construction and performance in force at the time the device was initially inspected and certified by an inspector or when the device or class, type or design of device was approved.
(2) Subsection (1) does not apply in respect of any device or class, type or design of device approved on a temporary basis pursuant to subsection 3(2) of the Act.
- SOR/90-118, s. 5
10 A static measure inspected and certified by an inspector on or before December 31, 1989 is exempt from paragraph 8(a) of the Act.
- SOR/90-118 s. 5
10.1 A device or class, type or design of device is exempt from paragraph 8(a) of the Act if every part of the device that can have an effect on the accuracy of the device or class, type or design of device is approved pursuant to section 3 of the Act.
- SOR/90-118, s. 5
Exemption from Paragraph 26(1)(b) of the Act
11 Since January 1, 1976, static measures that are not for use in trade are exempt from paragraph 26(1)(b) of the Act.
Notice of Importation
12 (1) The classes, types or designs of devices described in subsection 4(1) are exempt from subsection 26(2) of the Act.
(2) The notice to the Minister referred to in subsection 26(2) of the Act shall be in writing, shall be directed to the nearest Measurement Canada office within 10 days after the device is imported and shall contain the following information:
(a) the name and Canadian address of the importer;
(b) the date of entry of the device into Canada;
(c) the port of entry of the device;
(d) a description of the device sufficient to enable an inspector to identify it;
(e) if more than one device is imported, the number of devices imported;
(f) the address at which the device may be inspected;
(g) whether the device is of a class, type or design approved for use in trade, and if so, the approval number referred to in paragraph 17(c) for that class, type or design of device; and
(h) whether the device has been marked in accordance with these Regulations.
- SOR/93-234, s. 2(F)
- SOR/2005-297, ss. 40, 41(F), 43
Specifications Relating to Approval
13 (1) In addition to the specifications set out in Part V, the Minister may establish specifications relating to the design, composition, construction and performance to which any device or class, type or design of device shall conform before it may be approved pursuant to section 3 of the Act.
(2) [Repealed, SOR/2005-297, s. 3]
(3) A device or class, type or design of device is exempted from the application of any or all of the provisions of the specifications set out in Part V or established under subsection (1) if
(a) the provision or provisions are inapplicable or inappropriate taking into account
(i) the distinctive characteristics of the design, composition and construction of the device or class, type or design of device, or
(ii) the use for which the device or class, type or design of device is to be approved pursuant to section 3 of the Act; or
(b) the device or class, type or design of device provides a degree of accuracy and security that is at least equivalent to the degree provided by a device or class, type or design of device that meets the requirements of the provision or provisions of the specifications.
(4) Where a device or class, type or design of device is exempted from the application of any or all of the provisions of the specifications set out in Part V or established under subsection (1), the exemption shall be set out in the notice of approval issued pursuant to section 3 of the Act.
- SOR/78-792, s. 1
- SOR/90-278, s. 1
- SOR/93-234, s. 2
- SOR/2005-297, s. 3
Application for Approval of a Class, Type or Design of Device
14 An application for the approval of a device, or of a class, type or design of device for use in trade shall be made in writing to the Minister and shall contain the following information:
(a) a description of the commodity that a device of that class, type or design is designed to measure;
(b) the different units of measurement registered by a device of that class, type or design;
(c) the range of flow rate or capacity of a device of that class, type or design; and
(d) where the manner of installation or use affects the performance of a device of that class, type or design, the manner in which the device is to be installed or used.
- SOR/85-736, s. 1
- SOR/2005-297, s. 41(F)
15 (1) The application referred to in section 14 shall be accompanied by duplicate copies of
(a) test data relating to the actual service performance of the device or to the simulated service performance of the device;
(b) the principal drawings and specifications to be used by the manufacturer in assembling, testing and, where applicable, installing devices of that class, type or design; and
(c) the promotional material, bulletins, brochures, instructions and other information distributed or intended for distribution to purchasers or prospective purchasers of a device of the class, type or design to which the application relates.
(2) A person who submits an application under section 14 shall, when requested to do so by the Minister, supply to the Minister such additional information, test data, drawings or specifications as are necessary to enable the Minister to deal with the application.
- SOR/2005-297, s. 41(F)
16 Upon the request of the Minister and under such conditions as may be specified by him, the applicant shall make available to the Minister one or more devices of the class, type or design to which the application relates, together with such information, equipment, material and services as are required to examine and test the device.
- SOR/2005-297, s. 41(F)
Notice of Approval
17 Where the Minister approves a class, type or design of device for use in trade, he shall issue to the applicant therefor a written notice of approval containing the following information:
(a) a description of the class, type or design of device approved;
(b) the date of approval;
(c) the approval number assigned to the class, type or design of device approved;
(d) where a class, type or design of device is approved for use in trade for a specific purpose only, the specific purpose for which it may be used and the purpose for which its use is prohibited;
(e) where a class, type or design of device is approved for use in trade in a specific manner only, the specific manner in which it may be used and the manner in which its use is prohibited;
(f) such information relating to specifications for installation or use of a device of the class, type or design approved as the Minister considers necessary;
(g) the markings that are required to be shown on a device of that class, type or design; and
(h) such other information as the Minister considers necessary.
- SOR/2005-297, s. 41(F)
Form of Marking of Devices
18 (1) With the exception of weighing devices to which the Specifications Relating to Non-automatic Weighing Devices (1998) apply, the information required by these Regulations to be marked on a device shall be marked
(a) on the device;
(b) on a plate or plates permanently affixed to the device;
(c) partly on the device and partly on a plate or plates that are permanently affixed to the device; or
(d) in the case of a device not large enough to accommodate the required information in the manner referred to in paragraph (a), (b) or (c), on a notice attached to or displayed in close proximity to the device.
(2) Where information is marked on a plate, a suitable area of not less than 12 mm by 25 mm or ½ inch by 1 inch shall be left blank on the plate for the inspection mark referred to in section 29 and the plate shall be made of a durable material and shall be so located and mounted that it can be stamped with a steel die.
(3) The information required by these Regulations to be marked on the device shall be shown in numbers or letters that are
(a) permanent;
(b) clear;
(c) of a height reasonably appropriate to the size of the device and, unless otherwise specified in these Regulations or in specifications established by the Minister, in numbers or letters of not less than 3 mm or 1/8 inch in height; and
(d) located in such a place as to be readily legible by a person using the device under normal conditions of use.
(4) When numbers are used with letters or in place of letters on any marking on a device, the size and height of the numbers shall correspond to the size and height of the letters used or required to be used thereon by these Regulations.
- SOR/93-234, s. 2(F)
- SOR/98-115, s. 2
- SOR/2005-130, s. 2
Marking Static Measures Approved for Use in Trade
19 Before being sold, leased or otherwise disposed of, a static measure that is of a class, type or design approved for use in trade and that is manufactured on or after January 1, 1976 shall be marked with the following information:
(a) the name or registered trade mark of the manufacturer or importer of the measure;
(b) the approval number for that class, type or design of measure;
(c) the capacity of the measure expressed in terms of the appropriate unit of measurement;
(d) the words “Legal for Trade” (“Légal pour le commerce”); and
(e) any other information required to be marked on the device by the notice of approval.
- SOR/2005-297, s. 41(F)
Marking Weights Approved for Use in Trade
20 (1) Before being sold, leased or otherwise disposed of, a weight that is of a class, type or design approved for use in trade shall be marked with the following information:
(a) the number of units of mass or weight that the weight contains;
(b) in the case of a counterpoise weight used as part of a weighing machine, the number of units of mass or weight to which the weight is equivalent when used as a counterpoise with the weighing machine of which it forms a part;
(c) in the case of a weight of 1 gram or multiple or submultiple thereof, the word “gram” or its symbol “g”, together with the appropriate prefix or symbol as set out in Part V of Schedule I to the Act;
(d) in the case of a weight of 1 troy ounce, or multiple or submultiple thereof, the word “troy” or its abbreviation; and
(e) in the case of a weight of any avoirdupois unit or multiple or submultiple thereof that is manufactured or imported after January 1, 1976, the name of the unit or the symbol or abbreviation for the unit.
(2) Paragraphs (1)(c), (d) and (e) do not apply to a weight that is so small that it is impracticable to show the information required by those paragraphs.
(3) Paragraph (1)(a) does not apply to
(a) sheet metal or wire weights of 1 milligram or multiples or submultiples thereof, or
(b) sheet metal or wire weights of 1 grain or multiples or submultiples thereof
if the weights are manufactured in the customary distinctive shapes to denote the multiple or submultiple of the milligram or grain that the weight represents.
- SOR/2005-297, s. 41(F)
Marking Approved Weighing Machines, Measuring Machines and Related Equipment and Accessories
21 Before being sold, leased or otherwise disposed of, a weighing machine (other than a weighing device to which the Specifications Relating to Non-Automatic Weighing Devices (1998) apply) or a measuring machine, that is of a class, type or design approved pursuant to section 3 of the Act, and any equipment or accessory attached to or used in conjunction with the machine that has or could have an effect on the accuracy of the machine and that was approved pursuant to section 3 of the Act shall be marked with the following information:
(a) the name of the manufacturer or importer of the machine, equipment or accessory;
(b) the model number and serial number of the machine, equipment or accessory;
(c) the approval number of the machine, equipment or accessory;
(d) in the case of a volumetric liquid meter,
(i) the minimum and maximum flow rates, and
(ii) if the meter is equipped with an automatic temperature compensator, the words “Volume corrected to 15°C” or “Volume corrigé à 15°C”, immediately adjacent to the registration of net quantity;
(e) in the case of a weighing machine, the maximum load that may be weighed on the machine;
(f) in the case of any equipment or accessory, the range for which it was approved pursuant to section 3 of the Act; and
(g) any other information that is required by the notice of approval issued pursuant to section 3 of the Act.
- SOR/90-118, s. 6
- SOR/98-115, s. 3
- SOR/2005-130, s. 3
22 Before being sold, leased or otherwise disposed of, a weighing machine or measuring machine that is of a class, type or design approved for use in trade and that is referred to in subsection 28(2) shall be marked “Not for Use in Trade until Inspected” (“Ne pas utiliser dans le commerce avant l’inspection”) or shall be marked in words that convey the same meaning, and such markings shall be in letters of not less than 12 mm or ½ inch in height and shall remain on the device until it has been inspected and is found to meet the requirements of the Act and these Regulations.
- SOR/93-234, s. 2(F)
- SOR/2005-297, s. 41(F)
23 (1) Before being sold, leased or otherwise disposed of, a weighing machine or measuring machine that is not of a class, type or design approved pursuant to section 3 of the Act and that is not exempt from approval pursuant to that section shall be marked “Not Legal for Trade” or “Non légal pour le commerce” in letters of not less than 6 mm in height.
(2) A device described in subsection 4(2) shall be marked “For Prepackaging Use Only” or “Pour préemballage seulement” in letters of not less than 6 mm in height.
- SOR/93-234, s. 2
- SOR/2005-297, s. 4
Marking Measuring Tanks
24 (1) Before being sold, leased or otherwise disposed of, a measuring tank that is of a class, type or design approved for use in trade shall be marked with the following information:
(a) the name of the manufacturer or importer of the tank;
(b) the model number and serial number of the tank;
(c) the approval number for that class, type or design of tank;
(d) the maximum capacity of the tank;
(e) in the case of a tank that contains one or more internal capacity indicators, the capacity of the tank at the level of each indicator and where there is more than one indicator, the various capacities shown in descending order;
(f) in the case of a tank that has been calibrated to a valve located immediately at the outlet of the tank or that has been calibrated to an emergency valve, the words “dry line calibration” (“calibré avec tuyauterie vide”);
(g) in the case of a tank that has not been calibrated as set out in paragraph (f), the words “wet line calibration” (“calibré avec tuyauterie pleine”); and
(h) in the case of two or more measuring tanks installed on a vehicle, a number or letter in an identifiable sequence commencing with the tank closest to the front of the vehicle and proceeding to the tank closest to the rear of the vehicle.
(2) Where two or more measuring tanks are installed on a vehicle, the information required by paragraphs (1)(a) to (g) may appear in one location if the tanks are identified in accordance with paragraph (1)(h) and the information is correlated to the number or letter shown on the tank.
(3) The information required by paragraphs (1)(f), (g) and (h) shall be shown in numbers or letters of not less than 12 mm or ½ inch in height.
(4) Every internal capacity indicator in a measuring tank shall be marked in numbers or letters at least 6 mm or ¼ inch in height
(a) to show the capacity of the tank at the level of the indicator; or
(b) to identify the indicator.
(5) Where the internal capacity indicator is identified in accordance with paragraph (4)(b), the identification and the capacity of the tank at the level of that indicator shall be shown on the outside of the neck or fill opening of the tank in numbers or letters of at least 12 mm or ½ inch in height.
(6) When two or more measuring tanks are installed on a vehicle, the discharge valve for each tank shall be marked in numbers or letters of not less than 6 mm or ¼ inch in height to show the tank from which the commodity is discharged.
- SOR/2005-297, s. 41(F)
Marking Devices “Not for Use in Trade”
25 A weighing machine or measuring machine that is of a class, type or design approved for use in trade pursuant to section 3 of the Act shall, before being sold, leased or otherwise disposed of for a use other than use in trade, be permanently marked “Not for use in trade” or “Ne pas utiliser dans le commerce” in letters of not less than 12 mm in height.
- SOR/90-118, s. 7
26 Where a trader has in his possession any device that is of a class, type or design approved for use in trade but that is not in his possession for use in trade, the trader shall, for the purpose of section 36 of the Act, mark the device “Not for Use in Trade” (“Ne pas utiliser dans le commerce”) or shall mark the device in words that convey the same meaning and the marking shall be in letters of not less than 12 mm or ½ inch in height.
- SOR/2005-297, s. 41(F)
Specifications Relating to Installation and Use
27 In addition to the specifications set out in Part V, the Minister may from time to time establish specifications relating to the installation and use of any device or class, type or design of device for use in trade.
- SOR/78-792, s. 2
- SOR/93-234, s. 2(F)
Inspection Pursuant to Paragraph 26(1)(c) of the Act
28 (1) Subject to subsections (2) and (3), a device that is of a class, type or design approved pursuant to section 3 of the Act or that is described in section 8, other than a static measure or a device described in subsection 4(2), shall not be sold, leased or otherwise disposed of unless
(a) the device is manufactured in Canada and the manufacturer has had it inspected by an inspector; or
(b) the device is imported into Canada and the dealer who imported the device has had it inspected by an inspector.
(2) Subsection (1) does not apply to any device, the performance of which cannot be inspected until the device is installed for use in trade, if the dealer
(a) marks the device as prescribed in section 22; and
(b) within five days after shipping the device, sends to the nearest Measurement Canada office a notice in writing stating
(i) the dealer’s name and address,
(ii) the name of the person to whom the device was shipped,
(iii) a description of the device, and
(iv) the address of the place where the device is to be installed.
(3) Subsection (1) does not apply in respect of a device that is to be sold, leased or otherwise disposed of for a use other than use in trade where the dealer
(a) marks the device in the manner set out in section 25; and
(b) within five days after selling, leasing or otherwise disposing of the device, sends to the nearest Measurement Canada office a notice in writing stating
(i) the name and address of the dealer,
(ii) the name and address of the person to whom the device was sold, leased or otherwise disposed of, and
(iii) a description of the device, including the approval number, serial number and model number.
(4) A dealer or trader who installs or causes to be installed a device described in subsection (2) for use in trade shall have the device inspected by an inspector before it is used in trade.
- SOR/90-118, s. 9
- SOR/93-234, s. 2
- SOR/2005-297, ss. 5, 40, 41(F)
Marking Devices after Initial Inspections Pursuant to Section 28
29 (1) Where a device is inspected as prescribed by subsection 28(1) or following the installation referred to in subsection 28(2) and the inspector determines that the device meets the requirements of the Act and these Regulations, he shall mark the device or the container in which the device is kept when not in use as prescribed by subsections (2), (3) and (4).
(2) A device referred to in subsection (1) shall be marked by means of a steel die or, where it is not practicable to do so, by means of a sticker.
(3) An inspection mark shall be located,
(a) in the case of a weighing or measuring machine that has a plate or plates permanently affixed to the machine, on the blank area of the plate referred to in subsection 18(2);
(b) in the case of a weighing or measuring machine that does not have a plate or plates permanently affixed to the machine, on a part of the machine where it will be readily legible to a person using the machine under normal conditions of use;
(c) in the case of a weight that has a lead plug, on the lead plug; and
(d) in the case of a weight that does not have a lead plug, on any appropriate part of the weight.
(4) Notwithstanding subsection (3), where a device is so small that it is not practicable to mark it in accordance with that subsection, the inspection mark shall be located on the container in which the device is kept when not in use.
- SOR/93-234, s. 2(F)
Inspections Pursuant to Subsection 15(1) of the Act
30 [Repealed, SOR/94-650, s. 1]
Marking Devices after Inspections other than Inspections Pursuant to Section 28
31 (1) Where a device is inspected pursuant to section 15, subsection 17(1) or section 18 of the Act and the inspector determines that the device meets the requirements of the Act and these Regulations, he shall mark the device in the following manner:
(a) in the case of a weighing machine or measuring machine, by attaching a sticker to the machine; and
(b) in the case of a weight that has a lead plug, by marking the plug by means of a steel die, after defacing any existing inspection mark on the plug.
(2) Notwithstanding subsection (1),
(a) in the case of a weight that does not have a lead plug, no new inspection mark shall be made following an inspection pursuant to section 15 or subsection 17(1) of the Act; and
(b) in the case of a weight that is so small that it is not practicable to mark it in accordance with subsection (1), the inspection mark shall be located on the container in which the device is kept when not in use.
- SOR/93-234, s. 2(F)
Sealing of Devices Pursuant to Subsection 19(2) of the Act
32 Except with respect to weighing devices to which the Specifications Relating to Non-Automatic Weighing Devices (1998) apply, where a volumetric liquid meter, measuring tank or electronic device is marked as prescribed by section 29 or 31, the inspector shall attach a seal of the self-adhesive, self locking or lead and wire type to such parts of the device as may be necessary in order that no adjustment, alteration or repair can be made to the device without breaking or removing the seal.
- SOR/98-115, s. 4
- SOR/2005-130, s. 4
Accessibility and Assistance for Inspecting, Testing and Sealing Devices
33 (1) Subject to subsection (2), the owner or person in possession of a device shall ensure that the location of the device, or access to it by customary means, is such that an inspector is able
(a) to inspect and test the device, including a visual examination of its particular elements;
(b) to verify the sealing means on the device and to seal it; and
(c) to transport and to manoeuvre the applicable local standards and other testing equipment by customary means in the amount and size necessary for the test.
(2) Subsection (1) does not apply where the owner or person in possession of the device agrees
(a) to supply the labour and to supply and arrange the facilities, test products, standards calibrated in relation to a relevant local standard and other testing equipment that may be required to inspect, examine, test and seal the device; or
(b) on the request of the inspector, to remove the device to a suitable location and to supply the equipment, material and services that may be necessary to inspect, examine, test and seal the device.
(3) [Repealed, SOR/2005-130, s. 5]
- SOR/98-115, s. 4
- SOR/2005-130, s. 5
Device Maintenance and Adjustment
34 A device shall be maintained in proper operating condition and, where cleanliness can affect its performance, shall be kept clean.
- SOR/98-115, s. 4
35 Where a device has a means of adjustment, an adjustment shall be made only to correct the condition that the adjustment is designed to correct and shall not be used to compensate for faulty installation or for worn or defective parts.
- SOR/98-115, s. 4
35.1 A person who alters, adjusts or repairs a device in a way that may affect the accuracy of measurement shall also take steps to ensure that the device is calibrated immediately after the alteration, adjustment or repair so that the measurement error is as close to zero as possible within the normal operating range of the device.
- SOR/98-115, s. 4
Rejected Static Measures
36 Where an inspector determines that a static measure that is or is to be used in trade does not meet the requirements of the Act and these Regulations, he shall deface any markings referred to in paragraphs 19(b) and (d).
37 [Repealed, SOR/90-118, s. 11]
Reporting Location of Devices Installed for Use in Trade
38 (1) This section and section 39 do not apply to a class or type of device referred to in subsection 4(1) or to a device used in a trade transaction referred to in section 7.
(2) Where a trader installs or causes to be installed for use in trade
(a) a volumetric liquid measuring machine as part of a receiving or dispensing system, or
(b) any other device that, before it is used, is installed on a base, foundation, frame or other means of support, or is incorporated into a structure or system specifically made or prepared for the device, and the manner of installation can affect the performance of the device,
the trader shall, within five days after the date of the installation, make a report in writing to the nearest Measurement Canada office containing the following information:
(c) the name and address of the trader;
(d) the make, model and serial number of the device;
(e) the range of flow rate or capacity of the device; and
(f) the address and description of the place where the device is installed.
(3) Where a device described in subsection (2) has been removed from its installation and is installed again, the trader who owns the device or holds it in his possession for use in trade shall, within five days after the date of the installation, make a report in writing to the nearest Measurement Canada office containing the information required by subsection (2) and the address and description of the place where the device was previously installed.
- SOR/2005-297, ss. 40, 41(F), 43
39 (1) Where a trader acquires a measuring machine for use in trade that is part of a receiving or dispensing system installed on a vehicle, he shall make a report in writing to the nearest Measurement Canada office within five days from the date of the acquisition containing the following information:
(a) the name and address of the trader;
(b) the make, model and serial number of the machine;
(c) the range of flow rate or capacity of the machine;
(d) the make, fleet and unit number of the vehicle on which the machine is installed;
(e) the address, if known, at which the machine was located prior to the acquisition; and
(f) the new address at which the machine can be inspected.
(2) Where a trader who owns or holds in his possession for use in trade a machine described in subsection (1) changes the address at which the machine can be found for inspection, he shall, within five days after the date of changing the address, make a report in writing to the nearest Measurement Canada office containing the information required by paragraphs (1)(a), (b), (c), (d) and (f) and the address at which the machine could have been inspected prior to the change of address.
- SOR/93-234, s. 2(F)
- SOR/2005-297, s. 40
Written Notice Subsequent to Repairing Device
40 (1) A device that is of a class or type referred to in subsection 4(1) or a device used in a trade transaction referred to in section 7 is exempt from paragraphs 29(a) and (b) and section 30 of the Act.
(2) The written notice referred to in subparagraph 29(a)(ii) of the Act shall be forwarded to the nearest Measurement Canada office within five days from the date of the repair of the device and shall contain the following information:
(a) the name and address of the person who made the repair;
(b) the name and address of the person to whom the repaired device will be sent;
(c) if known to the person who made the repair, the address of the place where the device will be located for inspection, if that address is different from the address referred to in paragraph (b);
(d) the date of completion of the repair;
(e) the make, model and serial number of the device;
(f) the range of flow rate or capacity of the device;
(g) a description of the repair made;
(h) a description of the tests made after the repair to determine the accuracy of the device, the results of such tests and the equipment used for the testing;
(i) [Repealed, SOR/81-623, s. 1]
(j) whether the person who made the repair removed or broke or found removed or broken any marking, tag or seal placed on or attached to the device by an inspector or a person who had previously adjusted, altered or repaired the device, and, where possible, a description of such marking, tag or seal; and
(k) where the person who made the repair removed or broke or found removed or broken any seal, whether he replaced it with another seal and, if so, a description of that seal and the number of the seal, if any.
- SOR/81-623, s. 1
- SOR/93-234, s. 2(F)
- SOR/2005-297, ss. 40, 41(F), 43
Report Subsequent to Altering, Adjusting or Repairing Device
41 (1) Where a person repairs a device that is or is to be used in trade without taking possession of it or adjusts or alters such a device, whether or not he takes possession of it, and the alteration, adjustment or repair is of a nature that may affect the accuracy of the device or may result in its no longer being of a class, type or design approved for use in trade, he shall, within five days after the date of the alteration, adjustment or repair, report the following information to the nearest Measurement Canada office:
(a) his name and address;
(b) the name and address of the person who has possession of the device;
(c) the address of the place where the device is located if that address is different from the address referred to in paragraph (b);
(d) the date of completion of the alteration, adjustment or repair;
(e) the make, model and serial number of the device;
(f) the range of flow rate or capacity of the device;
(g) a description of the alteration, adjustment or repair made;
(h) a description of the tests made after the alteration, adjustment or repair to determine the accuracy of the device, the results of such tests and the equipment used for such testing;
(i) [Repealed, SOR/81-623, s. 2]
(j) whether the person who made the alteration, adjustment or repair removed or broke or found removed or broken any marking, tag or seal placed on or attached to the device by an inspector or by a person who had previously altered, adjusted or repaired the device and, where possible, a description of such marking, tag or seal; and
(k) where the person who made the alteration, adjustment or repair removed or broke or found removed or broken any seal, whether he replaced it with another seal and, if so, a description of that seal and the number of the seal, if any.
(2) A report under subsection (1) shall be in writing, but an inspector may authorize the report to be made verbally, in which case the report shall be made verbally.
- SOR/81-623, s. 2
- SOR/2005-297, ss. 40, 41(F)
Reporting Removal of Marking or Tag or Breaking of Seals
42 The report referred to in paragraph 30(2)(b) of the Act shall be in writing, shall be forwarded to the nearest Measurement Canada office within five days of the removal of any marking or tag or breaking of any seal, or the discovery of the removal of any marking or tag or breaking of any seal, and shall contain the following information:
(a) the name and address of the person who has possession of the device;
(b) the make, model and serial number of the device;
(c) the range of flow rate or capacity of the device;
(d) the date on which the marking or tag was removed or was discovered to have been removed;
(e) the date on which the seal was broken or was discovered to have been broken;
(f) the circumstances, if known, of the removal of the marking or tag or of the breaking of the seal;
(g) a description, where possible, of the marking or tag that was removed or discovered to have been removed, and of the seal that was broken or discovered to have been broken; and
(h) a description of any seal and the number of the seal, if any, that was installed to replace the missing seal.
- SOR/2005-297, s. 40
Adjustments or Alterations Prescribed Pursuant to Section 16 of the Act
43 For the purpose of section 16 of the Act, the adjustments or alterations that an inspector may make to a device are such adjustments and alterations as are
(a) minor in character and unlikely to require a significant amount of time to complete; and
(b) needed to make the device comply with these Regulations and any additional specifications established pursuant to sections 13 and 27.
- SOR/89-570, s. 6(F)
- SOR/90-118, s. 12
Limits of Error of Devices
44 The limits of error of a device for the purposes of paragraph 24(b) of the Act are those set out
(a) as the in-service limits of error in the applicable table in Part V; or
(b) as the in-service limits of error in the applicable specifications established under subsection 13(1).
- SOR/89-570, s. 6(F)
- SOR/2005-297, s. 6
PART IICommodities and Services
Interpretation
45 In this Part and in Schedule II,
- individually measured commodity
individually measured commodity means a commodity that is measured and packaged in a manner other than in accordance with a predetermined fixed quantity and that is, as a result, sold in varying quantities; (marchandise mesurée individuellement)
- quantity
quantity means the net quantity of a commodity; (quantité)
- statement of quantity
statement of quantity means the quantity stated pursuant to section 9 of the Act. (déclaration de quantité)
- SOR/89-570, s. 1
- SOR/93-234, s. 2
Exemptions from Marking the Quantity of the Commodity
46 The following types of trade transactions are exempt from section 9 of the Act:
(a) sales or offers for sale of commodities that are weighed or measured in the presence of the purchaser at the time of sale;
(b) sales or offers for sale of commodities that are produced or manufactured only for export;
(c) sales or offers for sale by bakeries of bakery products that are not packaged before being offered for sale;
(d) retail sales or offers for sale of fresh fruits or fresh vegetables, if a sign or placard that shows the price per unit of measurement on which the total price of the commodity is based is displayed in close proximity to the commodity, and that are
(i) not packaged before being offered for sale,
(ii) packaged in a wrapper or confining band of less than 13 mm in width, or
(iii) packaged in a clear, transparent protective wrapping;
(e) sales or offers for sale by automatic vending machines or mobile canteens of individual servings of food that are prepared by a commissary and packaged before being offered for sale;
(f) sales or offers for sale of individual portions of food that are packaged before being offered for sale and served by a restaurant or other commercial enterprise with meals or snacks;
(g) sales or offers for sale of individually wrapped confections, commonly known as one-bite confections, that are offered for sale or sold individually; and
(h) sales or offers for sale of primary mill paper or primary paperboard products, where
(i) a statement of the net, gross or other quantity of the commodity and of the manner in which the quantity was calculated is shown in a legible manner on the side of the package containing the commodity that is visible to the purchaser under normal or customary conditions of sale or use, or on a shipping bill, bill of lading or other document accompanying the commodity, and
(ii) subject to section 49, the statement of quantity referred to in subparagraph (i) is accurate within the limits of error set out in Column II of an item of the appropriate Part of Schedule II for the stated quantity set out in Column I of that item.
- SOR/90-118, s. 13
- SOR/2005-297, s. 7
Manner of Showing Statement of Quantity
47 A commodity that is sold or offered for sale on the basis of number or measure shall show a statement of quantity
(a) in the case of a commodity, other than a commodity referred to in paragraph 46(h), that is packaged before being offered for sale, on the side of the package containing the commodity that is visible to the purchaser under normal or customary conditions of sale or use; and
(b) in the case of a commodity that is not packaged before being offered for sale, on a part of the commodity itself that is visible to the purchaser under normal or customary conditions of sale or use or on a shipping bill, bill of lading or other document accompanying the commodity.
- SOR/90-118, s. 14
47.1 The statement of quantity for a commodity set out in column I of Schedule I shall consist of at least one statement per parameter set out in column II.
- SOR/2005-297, s. 8
48 (1) When the statement of quantity is shown on the package or on the commodity itself, the statement shall be shown in a manner easily legible to the purchaser and shall be in letters of not less than 3 mm or 1/8 inch in height if printed or written by hand and in letters of not less than 2 mm or 1/12 inch in height if printed or written by any other means.
(2) When the statement of quantity is shown on a shipping bill, bill of lading or any other document accompanying the commodity, it shall be shown in a manner easily legible to the purchaser.
(3) Where the price of a commodity is determined on the basis of a unit of measurement, that unit of measurement shall be shown on the statement of quantity in a manner at least as prominent as any other unit of measurement shown on the statement of quantity.
Limits of Error for Commodities and Services
49 (1) Subject to subsection (2), the prescribed limits of error for the purposes of sections 9 and 33 of the Act are those set out in Column II of an item of the appropriate Part of Schedule II for the stated quantity set out in Column I of that item.
(2) Where a commodity is weighed or measured on a device for which the tolerance is prescribed in section 192, 193 or 268, the limits of error for the commodity shall be one and one-half times the in-service tolerance prescribed for the device.
(3) Where the quantity of a commodity is stated in a unit of measurement that is not set out in column I of the applicable Part of Schedule II, the quantity shall be converted to the appropriate unit set out in column I of that Part and the limit of error set out in column II for that quantity shall apply.
- SOR/89-570, s. 2, 6(F)
- SOR/98-115, s. 5
- SOR/2005-297, s. 9
49.1 For the purposes of section 34 of the Act, the limit of error applicable to the weight declaration of a commodity used to determine rail transportation charges for the commodity, obtained by in-motion weighing of cars carrying the commodity is one per cent of the declared net weight.
- SOR/90-278, s. 4
Inspection
50 (1) When an inspection is made of an individually measured commodity that is in a liquid state and has its quantity stated in units of volume, the quantity of the commodity shall be determined at the temperature at which it is customarily measured for sale.
(2) When an inspection is made of an individually measured commodity that is in a liquid state and has its quantity stated in units of volume at 15°C, the quantity of the commodity shall be determined at a temperature of 15°C.
- SOR/93-234, s. 2(F)
- SOR/2005-297, s. 10
51 (1) When an inspection is made of a standard quantity commodity that is in a liquid or near liquid state at a temperature of 20°C and has its quantity stated in units of volume, the quantity of the commodity shall be determined at a temperature of 20°C.
(2) When an inspection is made of a standard quantity commodity that is in a frozen state and has its quantity stated in units of volume, the quantity of the commodity shall be determined at the temperature at which it is customarily offered for sale.
- SOR/93-234, s. 2(F)
- SOR/2005-297, s. 10
Inspection by Sample
52 (1) The inspection of any quantity of prepackaged commodities, hereinafter referred to as a lot, each unit of which purports to contain the same quantity of commodity, that an inspector undertakes to determine whether the lot meets the requirements of the Act and these Regulations respecting the statement of quantity, shall be made by selecting and inspecting a sample from the lot.
(2) Subject to subsection (3), where a lot contains the number of units set out in Column I of an item of Part I of Schedule III, an inspector shall select from the lot a number of units not less than the number set out in Column II of that item, and the number of units selected shall constitute the sample referred to in subsection (1).
(3) Where, for the purpose of determining the quantity, other than for establishing the weight of the package containing the commodity, it is necessary to destroy a certain number of units in the lot, an inspector shall select, for destruction, not more than 10 per cent of the total number of units in the lot and not less than one unit, and the number of units selected shall constitute the sample referred to in subsection (1).
(4) The lot from which a sample was taken and inspected by an inspector does not meet the requirements of the Act and these Regulations respecting the statement of quantity where the inspector determines that
(a) the weighted average quantity of the units in the sample, as determined by the formula set out in Part II of Schedule III, is less than the stated quantity;
(b) the number of units in the sample that contain less than the stated quantity by more than the prescribed limits of error set out in Schedule II for that quantity is equal to or greater than the number set out in Column II of Part IV of Schedule III for the sample size set out in Column I thereof; or
(c) two or more units in the sample contain less than the stated quantity by more than twice the prescribed limits of error set out in Schedule II for that quantity.
- SOR/89-570, s. 3, 6(F)
PART IIILocal Standards
Interpretation
53 In this Part and in Schedule IV,
- cylindrical graduated standard
cylindrical graduated standard means a local standard of volume or capacity that is made of glass or metal, has a cylindrical shape and, if made entirely of glass, bears graduations on the glass or, if made of metal, bears graduations that are adjacent to a glass window in the metal; (étalon cylindrique gradué)
- gravimetric prover standard
gravimetric prover standard means a local standard consisting of a tank mounted on a weighing machine and used for determining
(a) the mass of a product, or
(b) the volume of a liquid on the basis of the mass registered on the weighing machine and the density of the liquid; (cuve étalon gravimétrique)
- hydrometer standard
hydrometer standard [Repealed, SOR/2005-297, s. 11]
- master meter standard
master meter standard means a local standard that registers by mechanical, electrical or electronic means or any combination thereof, in units or multiples or subdivisions of units of volume, the quantity of liquid that passes through the standard during an interval of operation; (compteur étalon-témoin)
- narrow neck glass standard
narrow neck glass standard [Repealed, SOR/93-234, s. 2]
- narrow neck metal standard
narrow neck metal standard [Repealed, SOR/93-234, s. 2]
- narrow neck standard
narrow neck standard means a local standard of volume or capacity that has, on or adjacent to the narrow neck of the standard, a mark indicating the volume or capacity of the standard, or that has a machined rim that indicates the volume or capacity of the standard; (étalon à col étroit)
- nominal value
nominal value means
(a) in the case of a local standard of mass or weight, the mass or weight shown on that standard,
(b) in the case of a local standard of length, the length between any two graduations on that standard,
(c) in the case of a narrow neck standard, the volume or capacity shown on that standard,
(d) in the case of a cylindrical graduated standard, the maximum volume or capacity shown on that standard,
(d.1) in the case of a stoppered pycnometer standard, the volume or capacity of the standard when filled and stoppered at reference conditions,
(e) in the case of a master meter standard, gravimetric prover standard, pressure hydrometer standard, standard of temperature or electricity measuring standard, the value shown by that standard for any particular test, and
(f) in the case of a pipe prover standard, the volume of the standard stabilized at a temperature of 15°C and 101.325 kPa internal pressure as shown on the certificate issued for that standard pursuant to section 13 of the Act; (valeur nominale)
- pipe prover standard
pipe prover standard means a local standard consisting of a pipe equipped with a piston or ball in which the volume of liquid displaced when the piston or ball traverses all or any part of the length of the pipe is registered by mechanical, electrical or electronic means or any combination thereof. (tube étalon)
- pressure hydrometer standard
pressure hydrometer standard means a local standard that indicates the density or relative density of a fluid under pressure. (hydromètre étalon à pression)
- SOR/90-118, s. 15
- SOR/93-234, s. 2
- SOR/2005-297, s. 11
Tolerances for Local Standards
54 (1) Subject to subsection (2), the amount set out in Column II of an item in the appropriate Part of Schedule IV is hereby prescribed to be the tolerance for the purpose of subsection 13(1) of the Act for a local standard that has a nominal value set out in Column I of that item.
(2) Where a local standard is tested to determine whether it is within the tolerance set out in a Part of Schedule IV for that local standard and the nominal value of that local standard is not specified in Column I of an item of that Part, the tolerance for that local standard shall be the amount resulting from linear interpolation between the tolerances set out in Column II of that Part opposite the specific nominal values set out in Column I of that Part that are nearest to the nominal value of the local standard being tested.
(3) The tolerances set out in Parts XI and XII of Schedule IV for the nominal value of cylindrical graduated standards are also the tolerances for any other values that are marked on those standards as intermediate graduations.
(4) For the purposes of subsection 13(1) of the Act, the tolerance for a local standard referred to in subsection 56(2) at any point within the measuring range designated by the owner of the standard for the purpose of use of the standard is two per cent of the value or reading of that point indicated by the reference standard.
- SOR/86-132, s. 1
- SOR/89-570, s. 6(F)
- SOR/2005-297, s. 12
55 [Repealed, SOR/90-118, s. 16]
Calibration and Certification of Local Standards
56 (1) Every local standard described in column I of the table to this subsection shall be calibrated and certified at least once within the period set out in column II.
Item Column I Column II Local Standard Period 1 A weight, other than a weight referred to in items 2 to 4, that is used by an inspector in inspecting devices for use in trade 1 year 2 A weight that is retained in one location and that is used exclusively in inspecting discontinuous totalizing weighing systems at that location 5 years 3 A weight, other than a troy weight, that is retained at a Measurement Canada office 5 years 4 A troy weight that is retained at a Measurement Canada office 10 years 5 A static volumetric measure other than a measure described in item 6 1 years 6 A static volumetric measure that is made of glass 10 years 7 A stoppered pycnometer standard 10 years 8 A volumetric liquid measuring machine, other than a volumetric liquid meter, that has a valve or any other moving or movable part that has or can have an effect on the accuracy of the machine 4 years 9 A volumetric standard not otherwise provided for in this table 2 years 10 A static linear measure 10 years 11 A standard of temperature (a) of the glass capillary type 10 years (b) of any other type 2 years 12 A standard of density of the pressure hydrometer type 10 years 13 A standard of electricity measuring watt hours 1 years 14 A standard of electricity measuring volt ampere hours 1 years 15 A standard of electricity measuring var hours 1 years 16 A standard of electricity measuring amperes rms 5 years 17 A standard of electricity measuring volts rms 5 years (2) Where the tolerance for a local standard is that referred to in subsection 54(4), every local standard described in column I of the table to this subsection shall be calibrated and certified at least once within the period set out in column II.
Item Column I Column II Local Standard Period 1 Any electricity measuring standard not specified in subsection (1) 1 years 2 Any gas measuring standard not specified in subsection (1) 2 years
- SOR/93-234, s. 2(F)
- SOR/2005-297, s. 13
56.1 [Repealed, SOR/2005-297, s. 13]
PART IVFees and Charges
57 [Repealed, SOR/79-747, s. 1]
58 In this Part,
- travel time
travel time means the time that is spent by an inspector travelling to and returning from the place where a service set out in subsection 59(1) is provided; (temps de déplacement)
- waiting time
waiting time means the time during which an inspector is ready to commence or continue the provision of a service set out in subsection 59(1) but is prevented from so doing because
(a) a device necessary to the provision of the service is being altered or adjusted by another person, or
(b) of actions or omissions affecting the provision of the service which are beyond the control of the inspector. (période d’attente).
- SOR/79-747, s. 1
- SOR/85-736, s. 2
- SOR/87-582, s. 1
- SOR/93-413, s. 1
59 (1) The fees and charges for the following services provided by an inspector shall be determined in accordance with Part I of Schedule V:
(a) inspection of a device in accordance with a request referred to in subsection 15(2) of the Act;
(b) initial inspection of a device pursuant to paragraph 8(b) of the Act;
(c) calibration of a standard, other than a standard used or intended to be used by an inspector to inspect a device, at the request of the owner or person in possession of the standard;
(d) inspection of a commodity at the request of the owner or person in possession of the commodity;
(e) examination of a device or provision of any other service related to an application for the approval of a device or of a class, type or design of a device referred to in section 14; and
(f) alteration or adjustment of a device with the consent of the owner or person in possession of the device.
(2) Where, in order to provide a service set out in subsection (1), an inspector provides or transports a piece of equipment or a vehicle described in column I of item 1 of Part II of Schedule V, the applicable charges set out in column II of that item shall be paid in addition to the fees and charges set out in Part I of that Schedule.
(3) The charges incurred by an inspector for accommodation, meals, incidental expenses and transportation referred to in Schedule V are determined in accordance with the rates and allowances set out in the “Travel Directive” contained in the Treasury Board Manual that are in effect at the time that the service set out in subsection (1) is provided.
(4) Where the fees and charges set out in Schedule V are calculated on the basis of time, that time includes travel time and waiting time.
- SOR/79-747, s. 1
- SOR/85-736, s. 2
- SOR/87-582, s. 2
- SOR/93-413, s. 1
60 [Repealed, SOR/94-650, s. 2]
61 [Repealed, SOR/85-736, s. 2]
62 [Repealed, SOR/93-413, s. 2]
63 Where, in order to make an inspection, an inspector requires any equipment, material or commodity that is not customarily supplied by a Measurement Canada office and that has not been supplied by the dealer or trader for whom the inspection is to be made, the cost of purchasing or renting the necessary equipment, material or commodity and transporting it to and from the place where the inspection is to be made shall, in addition to the fee and charge otherwise payable for the inspection, be a charge that shall be paid in relation to the inspection.
- SOR/93-234, s. 2(F)
- SOR/2005-297, s. 40
Payment of Fees and Charges
64 (1) Subject to section 21 of the Act, the fee and charge prescribed by these Regulations for the inspection, altering or adjusting of a device shall be paid by the owner of the device or by the person in possession of the device.
(2) Where a commodity is inspected pursuant to the Act, the fee and charge prescribed by these Regulations for inspecting the commodity shall be paid by the person who requests the inspection.
- SOR/93-234, s. 2(F)
PART VSpecifications Relating to Devices
Establishment of Specifications
65 (1) Subject to subsection (2), this Part establishes the specifications relating to
(a) the design, composition, construction and performance to which a class, type or design of device described in this Part shall conform before it may be approved for use in trade pursuant to section 3 of the Act; and
(b) the installation and use of any class, type or design of device described in this Part.
(2) Weighing devices to which the Specifications Relating to Non Automatic Weighing Devices (1998) apply are exempt from this Part.
- SOR/93-234, s. 2(F)
- SOR/94-691, s. 4(F)
- SOR/98-115, s. 6
- SOR/2005-130, s. 6
DIVISION IDevices in General
Design, Composition and Construction
66 Every device for use in trade shall be of such design, composition and construction as will reasonably ensure its ability to provide satisfactory accuracy throughout its normal life and eliminate means of perpetrating fraud when in use.
Performance
67 (1) Every device for use in trade set out in Column I of an item of the table to this subsection shall be of such stability that under all temperatures and other conditions that may normally be encountered in use, and without adjustments other than those specifically provided for use of the device, the device is capable of measuring accurately within applicable in-service limits of error throughout the applicable period set out in Column II of that item.
Column I Column II Item Device Period 1 Tank having a capacity greater than 450 L or 100 gallons 5 years 2 Slow-flow meter having a flow rate of 115 L or less per hour or 25 gallons or less per hour 5 years 3 Any device not described in item 1 or 2 2 years (2) Where a device is tested for performance and a specific value for the known test quantity is not set out in the applicable table to this Part or in specifications established pursuant to subsection 13(1), the acceptance limits of error and in-service limits of error shall be determined by linear interpolation between the lower and higher limits of error nearest to the known test quantity.
- SOR/80-290, s. 2
- SOR/89-570, s. 6(F)
- SOR/90-118, s. 17
- SOR/2005-297, s. 14
Installation and Use
68 (1) Every device for use in trade shall be installed, maintained and used so as to permit accurate measurement and eliminate means of perpetrating fraud when in use.
(2) A device referred to in subsection (1) shall not be used to measure any quantity of commodity unless the limit of error set out in Column II of an item of the appropriate Part of Schedule II for the stated quantity set out in Column I of that item is equal to or greater than
(a) the value of the minimum increment of registration of the device if the device has digital means of registration; or
(b) one-half the value of the minimum increment of registration of the device if the device has analogue means of registration only.
- SOR/90-118, s. 18
69 The installation and use of every device for use in trade shall conform to instructions for installation and use issued by the manufacturer or importer, unless there is an apparent contradiction between such instructions and the specifications set out in this Part or established by the Minister, in which case the specifications set out in this Part or established by the Minister shall prevail.
70 Where the use of a device in any manner or for any purpose is prohibited
(a) in the certificate of inspection issued at the time of the most recent inspection made under the Act, or
(b) in the notice of approval of that device pursuant to section 3 of the Act or pursuant to a notice of approval under a previous enactment,
the device shall, throughout the period of its use in trade, have closely associated with it or prominently displayed thereon a readily legible sign or notice setting out the manner or purpose of use that is prohibited.
- SOR/93-234, s. 2(F)
DIVISION IIWeights
Interpretation
71 In this Division, weight means a weight for use in trade.
Design, Composition and Construction
72 Weights shall be composed of any metal or metals not softer than brass, except that weights of less than one gram in the metric system or less than 10 grains in the Canadian system shall be composed of corrosion resistant metal.
73 Weight reducing holes shall be so made as to prevent the retaining of adjusting lead or foreign matter and the entire surface of weights shall be smooth and reasonably free from grooves or indentations in which foreign matter could accumulate.
74 If a weight is equipped with a ring, the ring shall not be removable.
75 Cast iron weights shall be painted with at least one coat of suitable waterproof metal sealer or primer, and may be also painted with a finish coat if the resulting aggregate coat is thin and durable.
76 When a cast iron weight is painted, it shall be calibrated after it receives the final paint coat.
77 All adjusting holes intended to hold lead in a weight shall be undercut or so made as to ensure that the lead is securely held in place and in no case shall the lead project beyond the surface of the weight.
78 At the time of inspection pursuant to paragraph 8(b) of the Act or section 28 of these Regulations, not more than two adjusting holes shall be provided in a single weight and at every inspection there shall be lead in each adjusting hole sufficient to accept an imprint from an inspection stamp.
- SOR/93-234, s. 2(F)
79 A counterpoise weight the principal section of which is too thin to hold an adjusting hole shall have a boss or lug of a size sufficient to hold the adjusting hole.
80 A weight with a cavity for loose adjusting material that is fitted with a screw top or plug shall be provided with a positive means of locking, other than by friction, the top or plug to the body of the weight.
81 Weights shall be constructed to represent
(a) multiples or submultiples of the kilogram, gram or milligram having values equal to 1, 2 or 5 × 10n units, where n is a positive or negative whole number or zero;
(b) multiples or decimal submultiples of the pound or troy ounce;
(c) multiples or binary submultiples of the pound or ounce; or
(d) multiples or decimal submultiples of the grain.
Performance
82 When a weight that has a market weight set out in Column I of an item in a table to sections 84 to 88 is tested for acceptance limits of error in relation to a local standard weight, the weight is within the acceptance limits of error if its actual weight determined by the test
(a) is not less than its marked weight; and
(b) does not exceed its marked weight by an amount in excess of the amount set out in Column II of that item.
- SOR/89-570, s. 6(F)
83 When a weight that has a marked weight set out in Column I of an item in a table to sections 84 to 88 is tested for in-service limits of error in relation to a local standard weight, the amount is within the in-service limits of error if its actual weight determined by the test
(a) is not more than its marked weight by an amount in excess of the amount set out in Column III of that item; and
(b) is not less than its marked weight by an amount in excess of the amount set out in Column IV of that item.
- SOR/89-570, s. 6(F)
84 (1) Subject to subsections (2) and (3) and sections 85 and 87, the limits of error set out in the following table apply to all weights that are multiples or submultiples of the gram, commonly called metric weights:
Column I Acceptance Limits of Error In-Service Limits of Error Column II Column III Column IV Item Marked Weight Over Marked Weight Over Marked Weight Under Marked Weight Milligrams Milligrams Milligrams Milligrams 1 10 0.5 0.4 0.2 2 20 0.6 0.6 0.3 3 50 1 1 0.5 4 100 1.5 1.5 0.8 5 200 2 2 1 6 500 3 3 1.5 Grams 7 1 5 5 2.5 8 2 7 7 3.5 9 5 10 10 5 10 10 15 15 8 11 20 20 20 10 12 50 30 30 15 13 100 50 50 25 14 200 70 70 35 15 500 100 100 50 Kilograms Grams Grams Grams 16 1 0.20 0.20 0.10 17 2 0.40 0.40 0.20 18 5 1 1 0.50 19 10 1.70 1.70 0.85 20 20 3.50 3.50 1.80 21 50 or over 0.015% of marked weight 0.015% of marked weight 0.0075% of marked weight (2) The limits of error for weights for use in conjunction with equal-arm pan-over-beam scales are twice the limits of error set out in the table to subsection (1).
(3) The limits of error for weights for use as ratio weights where the ratio is in excess of 100:1 are one-half the limits of error set out in the table to subsection (1).
- SOR/89-570, s. 6(F)
85 The limits of error set out in the following table apply to weights in special multiples of the gram that are approved only for use in conjunction with scales designed to be used for determining the butter-fat content of milk and the moisture content of butter:
Column I | Acceptance Limits of Error | In-Service Limits of Error | ||
---|---|---|---|---|
Column II | Column III | Column IV | ||
Item | Marked Weight | Over Marked Weight | Over Marked Weight | Under Marked Weight |
Grams | Milligrams | Milligrams | Milligrams | |
1 | 9 | 5 | 5 | 2.5 |
2 | 10 | 5 | 5 | 2.5 |
3 | 18 | 10 | 10 | 5 |
4 | 20 or over | 10 milligrams for each 20 grams | 10 milligrams for each 20 grams | 5 milligrams for each 20 grams |
- SOR/89-570, s. 6(F)
86 (1) Subject to subsections (2) and (3), the limits of error set out in the following table apply to all weights that are in multiples or submultiples of the avoirdupois pound and ounce:
Column I Acceptance Limits of Error In-Service Limits of Error Column II Column III Column IV Item Marked Weight Over Marked Weight Over Marked Weight Under Marked Weight Pounds Ounces Grains Grains Grains 1 1/64 0.06 0.06 0.03 2 1/32 0.08 0.08 0.04 3 1/16 0.12 0.12 0.06 4 1/8 0.18 0.18 0.09 5 0.01 0.20 0.20 0.10 6 ¼ 0.24 0.24 0.12 7 0.02 0.3 0.3 0.15 8 ½ 0.4 0.4 0.20 9 0.05 0.5 0.5 0.25 10 1 0.5 0.5 0.25 11 0.1 0.7 0.7 0.35 12 2 0.8 0.8 0.40 13 0.2 1.1 1.1 0.55 14 4 1.2 1.2 0.6 15 0.5 1.8 1.8 0.9 16 1 2.8 2.8 1.4 17 2 4.6 4.6 2.3 18 3 6 6 3 19 5 8 8 4 20 10 15 15 7.5 21 20 25 25 12.5 22 30 35 35 17.5 23 50 55 55 27.5 24 100 105 105 52.5 25 Over 100 0.015% of marked weight 0.015% of marked weight 0.0075% of marked weight (2) The limits of error for weights for use in conjunction with equal-arm pan-over-beam scales are twice the limits of error set out in the table to subsection (1).
(3) The limits of error for weights for use as ratio weights where the ratio is in excess of 100:1 are one-half the limits of error set out in the table to subsection (1).
- SOR/89-570, s. 6(F)
87 The limits of error set out in the following table apply to all weights of 100 grams or over that are in multiples or submultiples of the gram and are for use with a device designed to weigh precious metals and other commodities of comparable value:
Column I | Acceptance Limits of Error | In-Service Limits of Error | ||
---|---|---|---|---|
Column II | Column III | Column IV | ||
Item | Marked Weight | Over Marked Weight | Over Marked Weight | Under Marked Weight |
Grams | Milligrams | Milligrams | Milligrams | |
1 | 100 | 50 | 50 | 25 |
2 | 200 | 75 | 75 | 38 |
3 | 500 | 130 | 130 | 65 |
Kilograms | ||||
4 | 1 | 200 | 200 | 100 |
5 | 2 | 290 | 290 | 145 |
6 | 5 | 420 | 420 | 210 |
7 | 10 | 520 | 520 | 260 |
8 | 20 | 600 | 600 | 300 |
9 | 50 | 680 | 680 | 340 |
- SOR/89-570, s. 6(F)
88 The limits of error set out in the following table apply to all weights that are in multiples of the troy ounce:
Column I | Acceptance Limits of Error | In-Service Limits of Error | ||
---|---|---|---|---|
Column II | Column III | Column IV | ||
Item | Marked Weight | Over Marked Weight | Over Marked Weight | Under Marked Weight |
Troy Ounces | Grains | Grains | Grains | |
1 | 1 | 0.4 | 0.4 | 0.2 |
2 | 2 | 0.6 | 0.6 | 0.3 |
3 | 3 | 0.8 | 0.8 | 0.4 |
4 | 5 | 1 | 1 | 0.5 |
5 | 10 | 1.5 | 1.5 | 0.8 |
6 | 20 | 2 | 2 | 1 |
7 | 30 | 3 | 3 | 1.5 |
8 | 50 | 4 | 4 | 2 |
9 | 100 | 6 | 6 | 3 |
10 | 200 | 7 | 7 | 3.5 |
11 | 300 | 8 | 8 | 4 |
12 | 500 | 9 | 9 | 4.5 |
13 | 1,000 | 10 | 10 | 10 |
- SOR/89-570, s. 6(F)
Use of Weights
89 A weight shall be used only with a weighing machine with which it is compatible.
90 When not in use, a weight that, due to its small size is not individually stamped with a mark of inspection shall be stored in a receptacle that bears the inspection mark.
- SOR/93-234, s. 2(F)
DIVISION IIIStatic Volumetric Measures
Interpretation
91 In this Division, measure means a static volumetric measure for use in trade.
Design, Composition and Construction
92 Measures shall be free from ridges or indentations likely to entrap dirt or the commodity measured and shall empty completely when inverted.
93 The internal horizontal dimensions of a measure for liquids shall be such that the removal from it of an amount equal to the limit of error in deficiency will lower the liquid level by not less than 2.4 mm or 3/32 inch or, if the measure is transparent, by not less than 1.2 mm or 3/64 inch.
- SOR/89-570, s. 6(F)
94 Subject to section 95, a measure that is not transparent shall be so designed that its capacity is established by the brim and when a measure is equipped with a spout, pouring lip or anti-splash protection, not less than one third of the brim of the measure shall be in a plane parallel to the base.
95 When a measure is equipped with a lid or cover, the capacity of the measure shall be determined by the bottom of the neck unless a permanent defining line or indicator is provided on the neck.
96 Unless otherwise authorized by the Minister, all measures for solids shall be cylindrical, designed to be struck with a roller and be of a diameter that does not differ from either the depth or double the depth by more than five per cent.
97 A measure may be composed of any suitable material that
(a) has sufficient strength, rigidity and durability to maintain its form and accuracy and resist indentation, distortion or breakage under ordinary conditions of trade use; and
(b) is impervious to the commodity for which it is intended.
98 Unless clearly and permanently marked with the words “Calibrated to Contain” (“calibré pour recevoir”), a measure for liquids shall be of such capacity that, when filled to capacity with water, the indicated volume can be poured out of the measure.
Performance
99 When a measure that has an indicated volume set out in Column I of an item in a table to sections 101 to 103 is tested for acceptance limits of error in relation to a relevant local standard, the measure is within the acceptance limits of error if its actual volume determined by the test
(a) is not less than its indicated volume; and
(b) does not exceed its indicated volume by an amount in excess of the amount set out in Column II of that item.
- SOR/89-570, s. 6(F)
100 When a measure that has an indicated volume set out in Column I of an item in a table to sections 101 to 103 is tested for in-service limits of error in relation to a relevant local standard, the measure is within the in-service limits of error if its actual volume determined by the test
(a) does not exceed its indicated volume by an amount in excess of the amount set out in Column III of that item; and
(b) is not less than its indicated volume by an amount in excess of the amount set out in Column IV of that item.
- SOR/89-570, s. 6(F)
101 (1) Subject to subsection (3), the limits of error set out in the following table apply to all measures used for measuring liquids or solids in metric units of volume or capacity:
Column I Acceptance Limits of Error In-Service Limits of Error Column II Column III Column IV Item Indicated Volume Over Indicated Volume Over Indicated Volume Under Indicated Volume Litres Millilitres Millilitres Millilitres 1 0.001 0.05 0.05 0.025 2 0.002 0.10 0.10 0.050 3 0.005 0.25 0.25 0.125 4 0.01 0.40 0.40 0.20 5 0.02 0.80 0.80 0.40 6 0.05 2 2 1 7 0.10 3 3 1.50 8 0.20 5 5 2.50 9 0.50 10 10 5 10 1 15 15 7.50 11 2 30 30 15 12 5 50 50 25 13 10 75 75 37.50 14 20 100 100 50 15 50 200 200 100 (2) The limits of error in the table to subsection (1) apply to tests made on a “to deliver” basis with water at room temperature.
(3) The limits of error for measures used with grain testing scales are one-half the limits of error set out in the table to subsection (1).
- SOR/89-570, s. 6(F)
102 (1) The limits of error set out in the following table apply to all measures used for measuring liquids in Canadian units of volume or capacity:
Column I Acceptance Limits of Error In-Service Limits of Error Column II Column III Column IV Item Indicated Volume Over Indicated Volume Over Indicated Volume Under Indicated Volume Gills Fluid Ounces Fluid Ounces Fluid Ounces 1 ¼ 1/16 1/16 1/32 2 ½ 1/8 1/8 1/16 3 1 ¼ ¼ 1/8 Pints 4 ½ 3/8 3/8 3/16 5 1 ½ ½ ¼ Quarts 6 1 ¾ ¾ 3/8 7 2 1 1 ½ Gallons 8 1 1½ 1½ ¾ 9 2 1¾ 1¾ 7/8 10 3 2 2 1 11 5 3 3 1½ 12 10 5 5 2½ (2) The limits of error in the table to subsection (1) apply to tests made on a “to deliver” basis with water at room temperature.
- SOR/89-570, s. 6(F)
103 (1) Subject to subsection (3), the limits of error set out in the following table apply to all measures used for measuring solids in Canadian units of volume or capacity:
Column I Acceptance Limits of Error In-Service Limits of Error Column II Column III Column IV Item Indicated Volume Over Indicated Volume Over Indicated Volume Under Indicated Volume Pints Fluid Ounces Fluid Ounces Fluid Ounces 1 ½ ½ ½ ¼ 2 1 ¾ ¾ 3/8 Quarts 3 1 1¼ 1¼ 5/8 4 2 2 2 1 Gallons 5 1 3½ 3½ 1¾ 6 2 5 5 2½ Bushel 7 ½ 10 10 5 8 1 15 15 7½ (2) The limits of error in the table to subsection (1) apply to tests made on a “to deliver” basis with water at room temperature.
(3) The limits of error for measures used with grain testing scales are ¼ the limits of error set out in the table to subsection (1).
- SOR/89-570, s. 6(F)
Use of Measures
104 A measure shall rest on a level surface when the correctness of filling is being determined by the user.
105 Measures shall be used in a manner that will prevent dents or other damage thereto that would cause a change in capacity.
106 Measures for liquids shall be permitted to drain for sufficient time to ensure that the liquid delivered is not less than the indicated volume by more than the limits of error set out in Column IV of the tables to sections 101 to 103.
- SOR/89-570, s. 6(F)
DIVISION IVStatic Linear Measures
Interpretation
107 In this Division, linear measure means a static linear measure for use in trade.
Design, Composition and Construction
108 Rigid linear measures shall be smooth and straight and made of steel, brass, hardwood or such other dimensionally stable materials as will retain their shape and remain reasonably permanent under normal conditions of use.
109 The ends of linear measures made of wood or other materials susceptible to wear through use shall be protected by a material, not less durable than brass, permanently attached to the ends.
110 Tape linear measures shall be made of steel, woven tape or other suitable dimensionally stable and durable material.
111 The units of measurement on a linear measure shall be so identified as to prevent confusion between metric and Canadian units.
112 In any series of graduations on a linear measure, lines representing equal intervals, shall be uniform in size and character and spaced at equal intervals.
113 Where figures, words, symbols or combinations thereof are set out on a linear measure to define the value of sub-graduations, they shall not be so placed as to interfere with the accuracy of reading or to cause confusion to the user.
114 The width of a graduation line shall in no case be greater than the width of the minimum clear interval between graduations.
Performance
115 When a linear measure has an indicated length between ends or between one end and any graduation or between any two graduations and that length is set out in Column I of an item in a table to sections 118 and 119, and the linear measure is tested for acceptance limits of error in relation to a relevant local standard of length, the linear measure is within the acceptance limits of error in respect of such indicated length if the actual length determined by the test
(a) is not less than its indicated length, and
(b) does not exceed its indicated length
by an amount in excess of the amount set out in Column II of that item.
- SOR/89-570, s. 6(F)
116 When a linear measure has an indicated length between ends or between one end and any graduation or between any two graduations and that length is set out in Column I of an item in a table to sections 118 and 119, and the linear measure is tested for in-service limits of error in relation to a relevant local standard of length, the linear measure is within the in-service limits of error in respect of such indicated length if the actual length determined by the test
(a) is not less than the indicated length, and
(b) does not exceed its indicated length
by an amount in excess of the amount set out in Column III of that item.
- SOR/89-570, s. 6(F)
117 When a test referred to in section 115 or 116 is carried out on
(a) a tape linear measure, other than a land surveyor’s tape linear measure, the measure shall be supported on a flat surface;
(b) a metal tape linear measure that is designed to be used under tension and the measure has
(i) metric units of measurement and is 10 metres or less in length, it shall be subjected to a tension of 25 N,
(ii) metric units of measurement and is over 10 metres in length, it shall be subjected to a tension of 50 N,
(iii) only Canadian units of measurement and is 25 feet or less in length, it shall be subjected to a tension of 5 pounds, and
(iv) only Canadian units of measurement and is over 25 feet in length, it shall be subjected to a tension of 10 pounds;
(c) a woven tape measure that has metric units of measurement, it shall be subjected to a tension of 25 N;
(d) a woven tape measure that has only Canadian units of measurement, it shall be subjected to a tension of 5 pounds; and
(e) a metal tape measure that, when extended, becomes semi-rigid, it shall not be subjected to a tension during the test.
118 (1) Subject to subsection (2), the limits of error set out in the following table apply to all metal or woven fabric tape measures with graduations and markings in terms of metric units of length:
Item Column I Acceptance Limits of Error In-Service Limits of Error Column II Column III Indicated Length Over or Under Indicated Length Over or Under Indicated Length Metres Millimetres Millimetres 1 0.2 0.2 0.2 2 0.5 0.4 0.4 3 1 0.6 0.6 4 1.5 0.8 0.8 5 2 1 1 6 3 1.5 1.5 7 5 2 2 8 7 2.5 2.5 9 10 3 3 10 15 3.5 3.5 11 20 4 4 12 30 5.5 5.5 13 50 7.5 7.5 14 70 9 9 15 100 12 12 (2) The limits of error for rigid linear measures with graduations and markings in terms of metric units of length are twice the limits of error set out in the table to subsection (1).
- SOR/89-570, s. 6(F)
119 (1) Subject to subsection (2), the limits of error set out in the following table apply to all metal or woven fabric tape measures with graduations and markings in terms of Canadian units of length:
Item Column I Acceptance Limits of Error In-Service Limits of Error Column II Column III Indicated Length Over or Under Indicated Length Over or Under Indicated Length Feet Inches Inches 1 2 or less 1/64 1/64 2 3 to 6 1/32 1/32 3 10 3/64 3/64 4 15 1/16 1/16 5 20 3/32 3/32 6 30 3/32 3/32 7 50 1/8 1/8 8 75 3/16 3/16 9 100 3/16 3/16 10 150 ¼ ¼ 11 200 5/16 5/16 (2) The limits of error for rigid linear measures with graduations and markings in terms of Canadian units of length are twice the limits of error set out in the table to subsection (1).
- SOR/89-570, s. 6(F)
DIVISION VWeighing and Measuring Machines in General
Interpretation
120 In this Division,
- machine
machine means a weighing machine or measuring machine for use in trade, other than one referred to in the Specifications Relating to Non-Automatic Weighing Devices (1998); (appareil)
- registration
registration includes both visual indication and recorded representation of quantity, unit price or monetary value. (enregistrement)
- SOR/98-115, s. 7
- SOR/2005–130, s. 7
Design, Composition and Construction
121 A machine shall be of a design, composition and construction that will enable it to resist such exposure to vibration, the product measured, foreign matter, dirt, moisture and extremes of temperature as may be encountered in its intended service, so that wear of its moving components will be minimized, its accuracy will be maintained, its operating parts will continue to function properly and its means of adjustment will retain their settings.
122 and 123 [Repealed, SOR/98-115, s. 8]
124 Any electrical or electronic components, equipment or accessories attached to or used in conjunction with a machine that have or can have an effect on the accuracy of the machine shall function properly despite such steady-state and transient variations in the frequency, voltage and waveform of the electrical supply and disturbances in the surrounding electromagnetic and electrostatic field as may normally exist in the intended service.
125 When a machine requires an electrical power supply, the frequency, voltage and current requirements and any special limitations on the stability or quality of power supply required to enable the machine to measure accurately shall be marked on the machine.
126 A machine shall be provided with means of registration that are appropriate for the class, type or design of machine and for its intended service, installation and use.
- SOR/2005-297, s. 41(F)
127 All registrations shall be clear, definite and easily legible under conditions of normal use of the machine.
128 [Repealed, SOR/98-115, s. 9]
129 Where a machine provides a printed record of the registration on a ticket or form, the ticket or form shall contain a statement of
(a) the quantity measured in the transaction or, where permitted or required by these Regulations or by specifications established by the Minister, a start and finish print such that the quantity measured can be calculated by subtraction;
(b) when the computed price is shown, the unit price for the commodity measured;
(c) the name, symbol or abbreviation appropriate to the unit of measurement registered and, as applicable, to the unit price and total price; and
(d) such further information as may be required by these Regulations or by specifications established by the Minister.
- SOR/93-234, s. 2
130 A machine equipped with an indicator or printer shall be capable of giving a visual or printed indication that the device has been properly returned to start position before any commodity is measured.
131 The graduations on an analogue type of indicator or printer for a machine shall conform to the following specifications:
(a) in any series of graduations the lines or marks of corresponding graduations shall be uniform in size and character;
(b) the width of a graduation line or mark shall not be greater than the width of the minimum clear interval between graduations;
(c) graduation lines or marks shall be varied in length or size so that they may be accurately read;
(d) in a series of graduations, intervals representing identical quantities shall not differ by a ratio greater than 1.2 to 1;
(e) graduations intended to have specific values shall be defined by figures, words, symbols or combinations thereof uniformly placed with reference to the graduations and as close thereto as practicable, but not so positioned as to interfere with the accuracy of reading; and
(f) graduations and their defining figures, words and names or symbols or abbreviations for the unit of measurement shall be such that they will not become obliterated or illegible under conditions of normal use of the machine.
132 The indicating element of an analogue type of indicator and the imprint of an analogue printer of a machine shall conform to the following specifications:
(a) the indicating portion of a poise or pointer and its relation to any associated series of graduations shall be such that there will be no confusion as to the quantity indicated or printed;
(b) the indicating portion of a poise or pointer shall reach but shall not obscure the finest graduation with which it is used;
(c) if the indicating portion of a pointer and the graduations are in the same plane, there may be a distance of not more than 1.0 mm or 0.04 inch between the end of the indicating portion and the end of the graduations, the distance being measured along the line of the graduations;
(d) the width of an indicating line or of the indicating portion of a pointer shall not be greater than the width of the narrowest graduation with which it is used; and
(e) the clearance between an indicating line or the indicating portion of a pointer and the reading surface of the graduations shall not be more than 1.5 mm or 0.06 inch unless adequate provision is made to prevent errors due to parallax.
133 [Repealed, SOR/98-115, s. 10]
134 Mechanical digital means of registration for a machine of the drum cyclometer or similar type shall conform to the following specifications:
(a) all digits except the last shall remain centrally aligned;
(b) there shall be means to show when the last digit is centrally aligned;
(c) any graduation lines on the finest indicating element shall provide a decimal or binary subdivision of the quantity between its successive digits;
(d) the digits representing a whole unit of measurement or a decimal multiple thereof shall be of uniform size, character and colour;
(e) the digits representing a decimal submultiple of the unit of measurement shall be set apart by a decimal point or comma; and
(f) where required by specifications for the particular class or type of machine, the digits representing a decimal or binary fraction of the unit of measurement shall be differentiated from the other digits by their size, character, colour or by a supplementary symbol.
- SOR/2005-297, s. 41(F)
135 Electronic digital means of indication for a machine shall conform to the following specifications:
(a) all digits shall be of the same height;
(b) the digits representing a decimal submultiple of the unit shall be set apart by a decimal point or comma; and
(c) the brightness of the electronically displayed digits and other information shall be such that they may be easily read under normal conditions of use.
136 Associated with any digital registration by a machine there shall be suitably located defining words and the name, symbol or abbreviation for the unit or units of measurement appropriate in size and such that they will not become obliterated or illegible under normal conditions of use of the machine.
137 Indicators and printers for monetary values shall conform to the same specifications as indicators and printers for registration of units of quantity.
Performance
138 Within such limits of repeatability as may be required by these Regulations or by specifications established by the Minister, a machine shall be capable of repeating its registrations for each identical load or quantity delivered regardless of repeated manipulations of any or all of the elements of the machine in a manner approximating normal conditions of use of the machine.
139 (1) Subject to subsection (2), where a machine has or is installed with two or more means of registration that have the same units of measurement, the registrations shall be in accordance with the following criteria:
(a) in the case of electronic digital means of registration, the registrations thereof shall
(i) where the values of minimum increment of registration are the same, be in exact agreement, or
(ii) where the values of minimum increment of registration are not the same, be in agreement within 0.6 times the largest of those values of minimum increment of registration;
(b) in the case of mechanical digital means of registration, the registrations thereof shall be in agreement within 0.6 times the largest of the values of minimum increment of registration;
(c) in the case of analogue means of registration, the registrations thereof shall be in agreement within 0.25 times the largest of the values of minimum increment of registration; and
(d) in the case of combined digital and analogue means of registration, the registrations thereof shall be in agreement within 0.6 times the largest of the values of minimum increment of registration.
(2) A means of providing analogue registration that is of the servo-follower type and that is installed prior to January 1, 1976 shall be in agreement with any other analogue or digital means of registration connected to the same machine within twice the finest graduation.
- SOR/90-118, s. 19
- SOR/2005-297, s. 15
140 The registration of monetary value on a machine provided with means of registration for monetary value shall be in mathematical agreement with the quantity indication and unit price, within such monetary limits as may be allowed by these Regulations or by specifications established by the Minister and the machine shall have words or symbols to differentiate clearly between the monetary value and the quantity registrations.
Installation and Use
141 A machine that has electrical components or equipment or accessories attached to or used in conjunction with it that have or can have an effect on the accuracy of the machine shall be connected to an electrical supply the characteristics of which are as specified by the manufacturer of the machine and the electrical wiring and other electrical installation affecting the machine shall be in accordance with the specifications of the manufacturer and with specifications established by the Minister for that class, type or design of machine.
- SOR/2005-297, s. 41(F)
142 The installation and use of a machine shall be such as to ensure that it is protected from abnormal environmental factors such as excessive dust or extremes of temperature, vibration, electromagnetic or electrostatic fields that could have an adverse effect on its performance.
143 A machine, other than a scale used for prepackaging or a device described in subsection 4(2), shall be installed so that its primary means of indication can be clearly read by any party to the transaction for which the machine is being used, but, if such installation is not practicable, a secondary means of indication shall be provided to allow the parties to the transaction to read the indication.
- SOR/2005-297, s. 16
144 The primary indicator of a machine shall be so located as to allow an unobstructed view of the load-receiving element or the delivery outlet of the machine or, if owing to particular circumstances that is not feasible, a convenient means shall be provided for direct communication between an observer at the indicator and an observer at the load-receiving element or the delivery outlet.
145 to 148 [Repealed, SOR/98-115, s. 11]
149 A machine shall not be installed or used in conjunction with any supplementary means of registration unless that means of registration conforms to the specifications for registration set out in this Part and to the specifications established pursuant to subsection 13(1) and section 27.
- SOR/2005-297, s. 17
DIVISION VIWeighing Machines
Interpretation
150 In this Division,
- known test load
known test load means a load consisting of local standards or any other load the weight of which has been determined in relation to local standards; (charge connue)
- machine
machine means a weighing machine for use in trade, other than one referred to in the Specifications Relating to Non-Automatic Weighing Devices (1998);(appareil)
- registration
registration includes both visual indication and printed representation of quantity, unit price or monetary value. (enregistrement)
- SOR/90-118, s. 20
- SOR/98-115, s. 12
- SOR/2005-130, s. 8
Design, Composition and Construction
151 Where the accuracy of registration or zero-balance of a portable machine is affected when the machine is off level, the machine shall be equipped with self-locking or lockable means of levelling and a level indicator.
152. to 156 [Repealed, SOR/98-115, s. 13]
157 A machine shall be equipped with means to balance it at zero-load and if supplementary material is used for that purpose it shall be so enclosed that it cannot shift position or be readily removed or altered in such a way that the balance condition of the machine is affected.
158 A balance ball, balancing weight, spring adjustment, trim potentiometer or other zero adjusting means on a machine shall be operable only by a detachable tool, but on a machine of up to 15 kg or 30 pounds capacity, a balance ball may be operable without a detachable tool if the design provides for controlled friction to hold the balance ball in any set position.
159. to 168 [Repealed, SOR/98-115, s. 14]
169 When a machine is equipped with a ticket printer or a label printer, the printed numbers and letters shall be of such size, character and colour that they may be easily read under normal conditions of use.
170 [Repealed, SOR/98-115, s. 15]
171 A machine equipped with an electronic digital means of registration shall be capable of giving visual confirmation that it has been returned to zero-load within a range equivalent to the greater of
(a) ¼ of the value of the minimum increment of registration, and
(b) 0.01 per cent of the capacity of the machine.
- SOR/90-118, s. 21
172 (1) Subject to subsections (2) and (3), the value of the minimum increment of registration on a machine shall not be greater than 10 kg or 20 pounds unless the capacity of the machine exceeds 100 000 kg or 200,000 pounds, in which case the value of the minimum increment of registration shall not be greater than 20 kg or 50 pounds.
(2) The value of the minimum increment of registration on a tank scale that is designed for weighing alcohol or on a hopper scale that is designed for weighing grain in a terminal or transfer elevator shall not be greater than
(a) 5 kg or 10 pounds, if the capacity of the scale is equal to or less than 100 000 kg or 200,000 pounds;
(b) 10 kg or 20 pounds, if the capacity of the scale exceeds 100 000 kg or 200,000 pounds, but is equal to or less than 200 000 kg or 400,000 pounds; and
(c) 20 kg or 50 pounds, if the capacity of the scale exceeds 200 000 kg or 400,000 pounds.
(3) The value of the minimum increment of registration on a conveyor belt scale shall not be greater than 100 kg or 200 pounds.
- SOR/90-118, s. 21
173 [Repealed, SOR/98-115, s. 16]
Performance
174 Subject to sections 181 to 184 and 188 to 193, where a known test load set out in column I of an item of a table to section 176 or 177 is applied to a machine for the purpose of determining compliance with the acceptance limits of error, the machine is within the acceptance limits of error in respect of that known test load if the load registered by each means of registration of the machine is not greater or less than the known test load by an amount in excess of the amount set out in column II of that item.
- SOR/89-570, s. 6(F)
- SOR/90-118, s. 22
- SOR/98-115, s. 17
175 Subject to sections 181 to 184 and 188 to 193, where a known test load set out in column I of an item of a table to section 176 or 177 is applied to a machine for the purpose of determining compliance with in-service limits of error, the machine is within the in-service limits of error in respect of that known test load if the load registered by each means of registration of the machine is not greater or less than the known test load by an amount in excess of the amount set out in column III of that item.
- SOR/89-570, s. 6(F)
- SOR/90-118, s. 22
- SOR/98-115, s. 17
176 Subject to sections 188, 192 and 193, the limits of error set out in the following table apply to all machines registering in metric units of mass:
Item | Column I | Column II | Column III |
---|---|---|---|
Known Test Load | Acceptance Limits of Error | In-Service Limits of Error | |
Grams | Milligrams | Milligrams | |
1 | 50 | 500 | 650 |
2 | 70 | 550 | 750 |
3 | 100 | 650 | 850 |
Grams | |||
4 | 150 | 750 | 1 |
5 | 200 | 900 | 1.2 |
Grams | |||
6 | 300 | 1 | 1.4 |
7 | 500 | 1.3 | 2 |
8 | 700 | 1.6 | 2.4 |
Kilograms | |||
9 | 1 | 1.8 | 3 |
10 | 1.5 | 2.2 | 3.8 |
11 | 2 | 2.6 | 4.6 |
12 | 3 | 3.2 | 6 |
13 | 5 | 4.5 | 8.2 |
14 | 7 | 6 | 11 |
15 | 10 | 8.4 | 14 |
16 | 15 | 12 | 19 |
17 | 20 | 16 | 24 |
18 | 30 | 23 | 33 |
19 | 50 | 37.5 | 50 |
20 | Over 50 kg | 0.075% of known test load | 0.10% of known test load |
- SOR/89-570, s. 6(F)
- SOR/98-115, s. 18
177 Subject to sections 188, 192 and 193, the limits of error set out in the following table apply to all machines registering in avoirdupois units of mass or weight:
Column I | Column II | Column III | ||||
---|---|---|---|---|---|---|
Item | Known Test Load | Acceptance Limits of Error | In-Service Limits of Error | |||
Pounds | Ounces | Pounds | Ounces | Pounds | Ounces | |
1 | 0.1 | 0.001 or | 1/64 | 0.001 or | 1/64 | |
2 | 2 | 0.001 or | 1/64 | 0.001 or | 1/64 | |
3 | 0.15 | 0.001 or | 1/64 | 0.002 or | 1/32 | |
4 | 0.2 | 0.001 or | 1/64 | 0.002 or | 1/32 | |
5 | 4 | 0.001 or | 1/32 | 0.002 or | 1/32 | |
6 | 0.3 | 0.002 or | 1/32 | 0.002 or | 1/32 | |
7 | 0.5 | 0.002 or | 1/32 | 0.003 or | 1/32 | |
8 | 0.7 | 0.002 or | 1/32 | 0.003 or | 1/16 | |
9 | 12 | 0.002 or | 1/32 | 0.003 or | 1/16 | |
10 | 1.0 | 0.003 or | 1/32 | 0.004 or | 1/16 | |
11 | 1.5 | 0.003 or | 1/16 | 0.005 or | 3/32 | |
12 | 2 | 0.004 or | 1/16 | 0.006 or | 3/32 | |
13 | 3 | 0.005 or | 1/16 | 0.008 or | 1/8 | |
14 | 5 | 0.006 or | 3/32 | 0.011 or | 3/16 | |
15 | 7 | 0.007 or | 1/8 | 0.014 or | 7/32 | |
16 | 10 | 0.009 or | 5/32 | 0.018 or | 5/16 | |
17 | 15 | 0.013 or | 3/16 | 0.024 or | 3/8 | |
18 | 20 | 0.017 or | ¼ | 0.030 or | ½ | |
19 | 30 | 0.025 or | 3/8 | 0.041 or | 5/8 | |
20 | 50 | 0.039 or | 5/8 | 0.060 or | 1 | |
21 | 70 | 0.053 or | 7/8 | 0.077 or | 1¼ | |
22 | 100 | 0.075 or | 1¼ | 0.100 or | 1½ | |
23 | Over 100 pounds | 0.075% of known test load | 0.10% of known test load |
- SOR/89-570, s. 6(F)
- SOR/98-115, s. 19
178. to 180 [Repealed, SOR/98-115, s. 20]
181 When a machine that is of the self-indicating or semi-self-indicating type is tested by
(a) the removal of a known test load, in the case of a machine that is normally used for weighing following the addition of load, or
(b) the addition of a known test load, in the case of a machine that is normally used for weighing following the subtraction of load,
the acceptance and in-service limits of error are 1.5 times the limits of error set out in the tables to sections 176 and 177 and set out in sections 188 and 192.
- SOR/89-570, s. 6(F)
182 (1) Subject to subsections (2) and (3) and sections 188 and 192, the minimum limit of error when a machine is tested for acceptance or in-service limits of error is a weight equivalent to 0.05 per cent at the capacity of the machine or one minimum increment of registration, whichever is the lesser.
(2) The minimum limit of error for a railway track scale used exclusively in weighing railway cars is the greater of 15 kg or 30 pounds, and the value of the minimum increment of registration.
(3) In a strain test at a heavy duty scale, there shall be no minimum limit of error in respect of the known test load that is added to the strain load and the limit of error for a machine with digital registration shall not be increased as described in section 184.
- SOR/89-570, s. 6(F)
- SOR/90-118, s. 23
- SOR/93-234, s. 2(F)
183 On removal of all load from a machine, the means of registration of the machine shall immediately return to zero registration within a range equivalent to the greater of
(a) ¼ of the value of the minimum increment of registration, and
(b) 0.01 per cent of the capacity of the machine.
- SOR/90-118, s. 24
184 Subject to subsection 182(3), where a machine has digital increments of registration, the acceptance and in-service limits of error applicable to the digital registrations of the machine shall be increased beyond the limits of error otherwise applicable to the digital registrations of the machine by the equivalent of one-half the finest digital increment of registration.
- SOR/89-570, s. 6(F)
185 (1) Where a test consisting of the application to a machine of the same test load up to 10 times is carried out under conditions approximating conditions of normal use, the difference between the least registered load and the greatest registered load shall not exceed the absolute value set out in column II or III, as applicable, of an item of the appropriate table to sections 176 and 177 that corresponds to the known test load set out in column I of that item that is equivalent to the greatest registered load.
(2) Subsection (1) does not apply to the testing of a machine in accordance with subsection 189.2(1), 190(2) or 191(1) or (2).
- SOR/89-570, s. 6(F)
- SOR/90-278, s. 5
- SOR/93-234, s. 2(E)
186. and 187 [Repealed, SOR/98-115, s. 21]
188 Where a hopper scale or a tank scale referred to in subsection 172(2) has a capacity equal to or greater than 15 000 kg or 35,000 pounds,
(a) the acceptance limits of error for that scale are the greater of 0.05 per cent of the known test load and the value of the minimum increment of registration; and
(b) the in-service limits of error for that scale are the greater of 0.10 per cent of the known test load and the value of the minimum increment of registration.
- SOR/89-570, s. 6(F)
- SOR/90-118, s. 25
189 Where a static test is conducted on a railway track scale that is designed for in-motion weighing, the acceptance limits of error for the scale are those prescribed by section 174 and the in-service limits of error for the scale are those prescribed by section 175.
- SOR/89-570, s. 6(F)
- SOR/90-278, s. 6
189.1 (1) In sections 189.2, 190 and 191,
- reference car
reference car means a railway car the weight of which has been determined in relation to a relevant local standard. (wagon de référence)
(2) In sections 190 and 191,
- net known test load
net known test load means the difference between the static weight of a loaded reference car and the static weight of an empty reference car. (charge connue nette)
- SOR/90-278, s. 6
189.2 (1) Subject to subsection 182(2), where a railway track scale that is designed for in-motion weighing of uncoupled railway cars is tested dynamically, the acceptance limit of error and in-service limit of error for the scale are 0.15 per cent of the known weight of each reference car.
(2) The limits of error set out in subsection (1) apply to a test that consists of five reference cars passing over the railway track scale up to 10 times, under conditions approximating conditions of normal use.
(3) The reference cars referred to in subsections (1) and (2) shall be representative of the types and weight range of the railway cars for which the railway track scale is intended to be used.
- SOR/90-278, s. 6
190 (1) In this section, unit train or UT means a train composed of at least 10 coupled railway cars of the same type carrying the same product to one consignee. (train-bloc or TB)
(2) Where a railway track scale that is designed for the in-motion weighing of unit trains is tested dynamically, the acceptance limit of error and in-service limit of error for the scale are 0.15 per cent of the sum of the net known test load of all of the reference cars in the train that are weighed.
(3) The test referred to in subsection (2) shall not be conducted more than 10 times.
(4) The reference cars and the length of the train used in the test referred to in subsection (2) shall be representative of the types and weight range of the railway cars and length of the trains for which the railway track scale is intended to be used.
- SOR/89-570, s.6(F)
- SOR/90-278, s. 6
191 (1) Where a railway track scale that is designed for the in-motion weighing of individual coupled railway cars forming a train, and is used solely for determining transportation charges for commodities, is tested dynamically, the acceptance limits of error and in-service limits of error for the scale are the following:
(a) at least 70 per cent of the individual weights of the reference cars shall be within 0.2 per cent of the known individual static weight of those reference cars;
(b) not more than five per cent of the individual weights of the reference cars shall differ by more than 0.5 per cent from the known individual static weights of those reference cars; and
(c) the weight of an individual reference car shall not differ by more than one per cent from the known static weight of that reference car.
(2) Where a railway track scale referred to in subsection (1), used for a purpose other than determining transportation charges for commodities, is tested dynamically, the acceptance limit of error and in-service limit of error for each dynamic weighing are 0.15 per cent of the net known test load.
(3) The tests referred to in subsections (1) and (2) shall not be conducted more than 10 times.
(4) The reference cars and the length of the train used in the tests referred to in subsections (1) and (2) shall be representative of the types and weight range of the railway cars and length of the trains for which the railway track scale is intended to be used.
- SOR/89-570, s. 6(F)
- SOR/90-278, s. 6
192 Where a crane scale is designed for use in the weighing of freight to determine freight or shipping charges thereon, the acceptance and in-service of error are 0.5 per cent of the known test load, but not less than 0.125 per cent of the capacity of the scale.
- SOR/89-570, s. 6(F)
193 The acceptance limits of error and the in-service limits of error applicable to a continuous totalizing machine shall be 0.5 per cent of the known weight of the material used to test the machine if the machine
(a) was designed for the in-motion weighing of commodities to determine freight or shipping charges or is used solely for this purpose; or
(b) was designed for the in-motion weighing of raw material such as sand, gravel, crushed rock, crude ore or other materials of comparable value or is used solely for this purpose.
- SOR/89-570, s. 6(F)
- SOR/2005-297, s. 18
194 and 195 [Repealed, SOR/98-115, s. 22]
196 The load discrimination of a machine equipped with a self-indicating or semi-self-indicating means of registration of either the analogue or the digital type shall be such that for the purpose of determining compliance with the acceptance limits of error or in-service limits of error for the machine and at any load from zero to maximum capacity, the addition to or removal from the load-receiving element of a weight corresponding to 1.4 times the value of the minimum increment of registration shall cause a change in registration equal to or greater than the value of the minimum increment of registration.
- SOR/89-570, s. 6(F)
- SOR/90-118, s. 26
Installation and Use
197. to 201 [Repealed, SOR/98-115, s. 23]
202 An installed machine shall be protected against wind, rain, blowing snow, extremes of temperature, variations in electromagnetic and electrostatic fields and any abnormal conditions of use to ensure that the machine can measure accurately and is not subject to premature deterioration in performance.
203 Water from any source shall be drained away from the machine and all surfaces under the machine, including floors of pits, shall be kept dry.
204 Before use, a portable machine shall be placed on a level and stable supporting surface and shall be properly levelled.
205 [Repealed, SOR/98-115, s. 24]
206 A machine shall, before use, be adjusted to register zero when there is no load on the load receiving element, unless another mode of operation is allowed for the class, type or design of machine by specifications established by the Minister or by a notice of approval.
- SOR/2005-297, s. 41(F)
207 to 209 [Repealed, SOR/98-115, s. 25]
DIVISION VIILinear Measuring Machines
Interpretation
210 In this Division,
- known test length
known test length means a sample of a material that is representative in thickness and texture of the kind of material that a machine is designed to measure, the length of which has been determined in relation to a local standard; (longueur de contrôle connue)
- machine
machine means a linear measuring machine for use in trade. (appareil)
- SOR/90-118, s. 28
Design, Composition and Construction
211 The measuring element on a machine shall be designed and constructed so as to reduce to a practicable minimum any slippage of material being measured.
212 The registering element on a machine shall be readily returnable to a definite zero indication and means shall be provided on the machine to prevent the return of the registering element to less than zero registration.
213 Registrations of length and money value shall be accurate when the machine is operated at any speed and in any manner to which it may reasonably be subjected in trade use and when it is operated in either a forward or a backward direction.
Performance
214 Where a test that consists of measuring a known test length set out in Column I of an item of the appropriate table to sections 216 to 219 is carried out on a machine, the machine is within the acceptance limits of error in respect of the known test length if the length registered by the machine is
(a) not less than the known test length by an amount greater than the amount set out in Column II of that item; and
(b) not more than the known test length by an amount greater than the amount set out in Column III of that item.
- SOR/89-570, s. 6(F)
- SOR/90-118, s. 29
215 Where a test that consists of measuring a known test length set out in Column I of an item of the appropriate table to sections 216 to 219 is carried out on a machine, the machine is within the in-service limits of error in respect of the known test length if the length registered by the machine is
(a) not less than the known test length by an amount greater than the amount set out in Column IV of that item; and
(b) not more than the known test length by an amount greater than the amount set out in Column V of that item.
- SOR/89-570, s. 6(F)
- SOR/90-118, s. 29
216 The limits of error set out in the following table apply to all fabric machines registering in terms of metric units of length:
Item | Column I | Acceptance Limits of Error | In-Service Limits of Error | ||
---|---|---|---|---|---|
Column II | Column III | Column IV | Column V | ||
Known Test Length | Under Registration of Length | Over Registration of Length | Under Registration of Length | Over Registration of Length | |
Metres | Millimetres | Millimetres | Millimetres | Millimetres | |
1 | Up to 2 | 6 | 3 | 10 | 6 |
2 | 3 | 6 | 4 | 10 | 8 |
3 | 5 | 8 | 5 | 16 | 10 |
4 | 7 | 13 | 6 | 25 | 13 |
5 | 10 | 19 | 10 | 38 | 19 |
6 | 15 | 25 | 13 | 50 | 25 |
7 | Over 15 | 25 mm plus 1.5 mm per m of known test length | 13 mm plus 0.8 mm per m of known test length | 50 mm plus 3 mm per m of known test length | 25 mm plus 1.5 mm per m of known test length |
- SOR/89-570, s. 6(F)
217 The limits of error set out in the following table apply to all fabric machines registering in terms of Canadian units of length:
Item | Column I | Acceptance Limits of Error | In-Service Limits of Error | ||
---|---|---|---|---|---|
Column II | Column III | Column IV | Column V | ||
Known Test Length | Under Registration of Length | Over Registration of Length | Under Registration of Length | Over Registration of Length | |
Yards | Inches | Inches | Inches | Inches | |
1 | Up to 2 | ¼ | 1/8 | 3/8 | ¼ |
2 | 3 | ¼ | 5/32 | 3/8 | 5/16 |
3 | 5 | 5/16 | 3/16 | 5/8 | 3/8 |
4 | 7 | ½ | ¼ | 1 | ½ |
5 | 10 | ¾ | 3/8 | 1½ | ¾ |
6 | 15 | 1 | ½ | 2 | 1 |
7 | Over 15 | 1″ plus 1/16″ per yd. of known test length | ½″ plus 1/32″ per yd. of known test length | 2″ plus 1/8″ per yd. of known test length | 1″ plus 1/16″ per yd. of known test length |
- SOR/89-570, s. 6(F)
218 The limits of error set out in the following table apply to all machines for measuring rope, cordage, wire or woven screening in terms of metric units of length:
Item | Column I | Acceptance Limits of Error | In-Service Limits of Error | ||
---|---|---|---|---|---|
Column II | Column III | Column IV | Column V | ||
Known Test Length | Under Registration of Length | Over Registration of Length | Under Registration of Length | Over Registration of Length | |
1 | Any length | 25 mm plus 1% of known test length | 13 mm plus ½% of known test length | 25 mm plus 1% of known test length | 13 mm plus ½% of known test length |
- SOR/89-570, s. 6(F)
219 The limits of error set out in the following table apply to all machines for measuring rope, cordage, wire or woven screening in terms of Canadian units of length:
Item | Column I | Acceptance Limits of Error | In-Service Limits of Error | ||
---|---|---|---|---|---|
Column II | Column III | Column IV | Column V | ||
Known Test Length | Under Registration of Length | Over Registration of Length | Under Registration of Length | Over Registration of Length | |
1 | Any length | 1″ plus 1% of known test length | ½″ plus ½% of known test length | 1″ plus 1% of known test length | ½″ plus ½% of known test length |
- SOR/89-570, s. 6(F)
Installation and Use
220 A machine shall be firmly attached to a counter or other stable support before it is used.
221 Registration shall be returned to zero before each use of the machine.
DIVISION VIIIArea Measuring Machines
Interpretation
222 In this Division, machine means an area measuring machine for use in trade.
Design, Composition and Construction
223 A machine shall be designed so that any means of adjustment that can have an effect on its accuracy of measurement has provision for sealing.
Performance
224 When a machine is tested in relation to a relevant local standard for either acceptance or in-service limits of error by measurement of a known area on a surface representative of the kind of material for which the machine is designed, the machine is within both the acceptance and in-service limits of error in respect of that area and that kind of material if the area registered does not differ from the known area by more than 0.006 square metres or 1.5 per cent of the known area, whichever is greater, and, in the case of a machine measuring in Canadian units of measurement, 1/16 square foot or 1.5 per cent of the known area, whichever is greater.
- SOR/89-570, s. 6(F)
DIVISION IXSolid Volume Measuring Machines
Interpretation
225 In this Division, machine means a machine for determining the computed volume of boxes and other solids on the basis of three mutually perpendicular linear measurements.
Design, Composition and Construction
226 Measuring faces on a machine shall be designed so that they may be held parallel when each of the three principal axes of the object are being measured.
227 A machine shall provide registration of measurement in terms of either cubic decimetres or cubic feet.
Performance
228 When a machine is tested in relation to a relevant local standard for acceptance limits of error by taking the measurement in turn of three lengths the product of which corresponds to a computed volume set out in Column I of an item in a table to section 230 or 231, the machine is within the acceptance limits of error in respect of that computed volume if the amount registered by the machine
(a) is not less than the computed volume by an amount in excess of the volume set out in Column II of that item; and
(b) does not exceed the computed volume by an amount in excess of the amount set out in Column III of that item.
- SOR/89-570, s. 6(F)
229 When a machine is tested in relation to a relevant local standard for in-service limits of error by taking the measurement in turn of three lengths the product of which corresponds to a computed volume set out in Column I of an item in a table to section 230 or 231, the machine is within the in-service limits of error in respect of that computed volume if the amount registered by the machine
(a) is not less than the computed volume by an amount in excess of the volume set out in Column IV of that item; and
(b) does not exceed the computed volume by an amount in excess of the amount set out in Column V of that item.
- SOR/89-570, s. 6(F)
230 The limits of error set out in the following table apply to all solid volume machines designed to establish the space in cubic decimetres taken up by packages, parcels and crates:
Item | Column I | Acceptance Limits of Error | In-Service Limits of Error | ||
---|---|---|---|---|---|
Column II | Column III | Column IV | Column V | ||
Computed Volume | Under Registration of Volume | Over Registration of Volume | Under Registration of Volume | Over Registration of Volume | |
Cubic Decimetres | Cubic Decimetres | Cubic Decimetres | Cubic Decimetres | Cubic Decimetres | |
1 | Up to 30 | 0.3 | 0.15 | 0.3 | 0.15 |
2 | 50 | 0.5 | 0.25 | 0.5 | 0.25 |
3 | 100 | 0.8 | 0.40 | 0.8 | 0.40 |
4 | 200 | 1.2 | 0.60 | 1.2 | 0.60 |
5 | 300 | 1.5 | 0.75 | 1.5 | 0.75 |
6 | Over 300 | 0.5% of computed volume | 0.25% of computed volume | 0.5% of computed volume | 0.25% of computed volume |
- SOR/89-570, s. 6(F)
231 The limits of error set out in the following table apply to all solid volume machines designed to establish the space in cubic feet taken up by packages, parcels and crates:
Item | Column I | Acceptance Limits of Error | In-Service Limits of Error | ||
---|---|---|---|---|---|
Column II | Column III | Column IV | Column V | ||
Computed Volume | Under Registration of Volume | Over Registration of Volume | Under Registration of Volume | Over Registration of Volume | |
Cubic Feet | Cubic Feet | Cubic Feet | Cubic Feet | Cubic Feet | |
1 | Up to 1 | 0.010 | 0.005 | 0.010 | 0.005 |
2 | 2 | 0.020 | 0.010 | 0.020 | 0.010 |
3 | 5 | 0.036 | 0.018 | 0.036 | 0.018 |
4 | 10 | 0.050 | 0.025 | 0.050 | 0.025 |
5 | Over 10 | 0.5% of computed volume | 0.25% of computed volume | 0.5% of computed volume | 0.25% of computed volume |
- SOR/89-570, s. 6(F)
DIVISION XVolumetric Liquid Measuring Machines in General
Interpretation
232 In this Division, machine means a volumetric liquid measuring machine and includes a volumetric liquid meter or a measuring tank for use in trade.
Design, Composition and Construction
233 A machine shall be designed and constructed to ensure complete delivery of the measured liquid and to prevent delivery of any unmeasured liquid.
234 All movable capacity indicators and means of adjustment on a machine shall be sealable.
235 (1) Component parts of a machine the removal or alteration of which could have an effect on the accuracy of measurement of the machine shall be sealable.
(2) Subsection (1) does not apply to a meter designed for measuring liquid food commodities.
236 Except as otherwise authorized by specifications established by the Minister, a machine shall register in units of volume of liquid at the temperature and pressure of the liquid in the measuring element of the machine.
Performance
237 A machine may be tested and calibrated using a liquid other than the liquid that the machine will measure in trade if the test liquid has hydraulic properties similar to the liquid that the machine will measure in trade or the test liquid is used with a correction factor that has been specified by the Minister.
Installation and Use
238 Where a machine is incorporated into a measuring system, the component parts of the system, including the liquid supply tank and any pump, piping, valve or delivery hose, shall be installed and used so as not to cause the machine to cease to measure accurately.
239 Unless otherwise authorized by specifications established by the Minister, a machine shall be installed so as to prevent the inter-mixing of liquids therein unless it is a machine approved for that purpose.
240 When a machine is installed in conjunction with piping other than a delivery hose or a short jumper hose, the piping shall be of rigid material.
DIVISION XIVolumetric Liquid Meters
Interpretation
241 In this Division,
- meter
meter means a volumetric liquid measuring machine for use in trade that is of the meter type or incorporates a meter; (compteur)
- registration
registration includes both visual indication and recorded representation of volume, unit price or monetary value. (enregistrement)
Design, Composition and Construction
242 The rated maximum flow of a meter shall be such that, when it is tested using refined petroleum products with normal lubricating properties such as kerosene or fuel oil, the meter will measure accurately without abnormal wear, and the meter shall be de-rated if necessary for use on products with lesser lubricating properties.
243 (1) The rated minimum flow of a meter designed to measure liquids other than liquefied gases shall be 20 per cent or less of the rated maximum flow of the meter.
(2) Subject to subsection (3), the rated minimum flow of a meter designed to measure liquefied gases shall be 33 per cent or less of the rated maximum flow of the meter.
(3) The rated minimum flow of a meter with a rated maximum flow of 90 L or less per minute that is designed to measure liquefied gases and to dispense liquefied gases to motor vehicles shall be 13 L or less per minute.
- SOR/90-118, s. 30
244 Unless otherwise authorized by specifications established by the Minister, a meter shall have an integral filter or close-coupled strainer appropriate to the type, design and size of the meter.
245 Unless otherwise authorized by specifications established by the Minister, all meters except slow-flow meters and slow-flow dispensers shall have an automatic air-vapour eliminator and a meter for liquefied gases shall also have a combination differential-pressure and back-pressure valve.
246 Any accessory for a liquid meter that can affect the accuracy of the meter shall be sealable.
247 [Revoked, SOR/93-234, s. 2]
248 [Revoked, SOR/90-118, s. 31]
249 (1) Subject to subsection (2), the means of registration on a meter shall be capable of advancement only by the liquid passing through the meter.
(2) A meter register may be designed to be reset to zero by mechanical advancement of the register elements if, during the resetting,
(a) the elements of registration are obscured until the zero position is reached; or
(b) the advancing movement, once started, cannot be stopped until the zero position is reached.
250 The indications on any resettable register, totalizer or ticket printer on a meter that is designed to measure flow in both directions shall advance or reverse according to the flow of the liquid.
251 When a meter has a totalizer or preset register, it shall be clearly differentiated from the delivery register.
252 A resettable register shall have means to return the register accurately to zero, and the money register of a computing type register shall return to zero at the same time that the quantity register is returned to zero.
253 A computing type register shall be designed to prevent any change of the price setting during a delivery and so as to automatically display the unit price at which the register is set to compute.
254 A meter with a rated maximum flow of 350 L or less per minute that is intended to be used to measure and deliver motor fuel to motor vehicles, watercraft and aircraft shall be designed to be inoperable after a delivery until the register is reset to zero.
- SOR/90-118, s. 32
- SOR/93-234, s. 2(E)
255 [Revoked, SOR/93-234, s. 2]
256 Unless otherwise authorized by specifications established by the Minister, a ticket printer shall be interlocked so that it can
(a) print only the quantity delivered; and
(b) deliver only the quantity for which a ticket is printed.
257 A meter that has a ticket printer shall be so designed that a jammed ticket can be removed without breaking the inspection seals on the means of adjusting the registration.
- SOR/90-118, s. 33
258 Where an automatic temperature-compensated or other type of compensated register is installed on a meter, an uncompensated register shall also be provided that indicates the uncompensated volume measured by the meter.
259 The purchaser’s cumulative register on a key-operated self-serve meter shall be designed so that it is readily visible to the purchaser at the time of delivery and will permit comparison with the quantity indication of the delivery shown by the primary indicator.
260 A meter shall have a sealable means of adjustment that will permit the meter to be adjusted to within 0.05 per cent of the quantity dispensed through the meter.
- SOR/90-118, s. 34
Performance
261 When a meter is tested for acceptance limits of error at any flow rate between its rated maximum flow and its rated minimum flow using a known test quantity of liquid set out in Column I of an item in the applicable table to sections 265 to 270, the meter is within the acceptance limits of error in respect of that quantity if the quantity registered by the meter does not differ from the known test quantity by an amount in excess of the amount set out in Column II of that item.
- SOR/89-570, s. 6(F)
262 When a meter is tested for in-service limits of error at any flow rate between its rated maximum flow and its rated minimum flow using a known test quantity of liquid set out in Column I of an item in the applicable table to sections 265 to 270, the meter is within the in-service limits of error in respect of that quantity if the quantity registered by the meter does not differ from the known test quantity by an amount in excess of the amount set out in Column III of that item.
- SOR/89-570, s. 6(F)
263 Where a meter is tested for acceptance limits of error or in-service limits of error using three consecutive tests conducted at any single rate of flow or at any flow rate of the same pattern that falls between its rated maximum flow and its rated minimum flow, the spread of the test results shall not exceed two fifths of the applicable limit of error for the meter.
- SOR/89-570, s. 6(F)
- SOR/2005-297, s. 19
264 [Revoked, SOR/90-118, s. 35]
265 (1) Subject to subsection (4), the limits of error set out in the tables to subsections (2) and (3) apply to slow-flow dispensers incorporating either meters or self-measuring pumps, dispensers for motor fuel of the service station type, meters on refuellers for small aircraft and boats, meters on vehicle tanks and to all other meters for use in measuring automotive or petroleum liquids in retail trade and that are not otherwise mentioned in the tables in this Division.
(2) The limits of error set out in the following table apply to meters that register in metric units of volume:
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error Litres Millilitres Millilitres 1 0.10 2 4 2 0.20 2.5 5 3 0.50 6 12 4 1 10 20 5 2 15 30 6 5 30 60 7 10 40 80 8 20 50 100 9 50 100 200 10 100 220 440 11 250 or more 3/16% of known test quantity 3/8% of known test quantity (3) The limits of error set out in the following table apply to meters that register in Canadian units of volume:
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error Pints Fluid Ounces Fluid Ounces 1 ½ 1/8 ¼ 2 1 ¼ ½ Quarts 3 1 3/8 ¾ 4 2 5/8 1¼ Gallons 5 1 1 2 6 2 1¼ 2½ 7 5 2 4 8 10 3½ 7 9 20 6½ 13 10 50 or more 3/16% of known test quantity 3/8% of known test quantity (4) The acceptance limits of error set out in Column II of the tables to subsections (2) and (3) apply only to tests made under controlled conditions such as bench tests, and for tests for acceptance limits of error under other conditions, the limits of error set out in Column III of those tables shall apply.
- SOR/89-570, s. 6(F)
266 (1) Subject to subsections (4) and (5), the limits of error set out in the tables to subsections (2) and (3) apply to all positive displacement bulk volumetric liquid meters, including vehicle-mounted meters that are designed to measure volumes of 180 litres or more or 40 gallons or more of refined petroleum products such as gasoline and fuel oils, foodstuffs such as milk, liquid fertilizers of the solution type such as aqua ammonia or other liquids of low viscosity.
(2) The limits of error set out in the following table apply to meters, generally of a size 65 mm or 2½ inches or smaller that are designed to measure liquids of low viscosity:
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error 1 Any volume of 225 litres or more up to 900 litres or of 50 gallons or more up to 200 gallons 3/16% of known test quantity ¼% of known test quantity (3) The limits of error set out in the following table apply to meters, generally of a size 75 mm or three inches or larger that are designed to measure liquids of low viscosity:
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error 1 Any volume of 1 350 litres or more or of 300 gallons or more 1/8% of known test quantity ¼% of known test quantity (4) The acceptance and in-service limits of error set out in the tables to subsections (2) and (3) apply to known test quantities equal to or greater than that delivered by the meter in one minute at the maximum operating rate.
(5) The acceptance limits of error set out in Column II of the tables to subsections (2) and (3) apply only to tests made under controlled conditions such as bench tests and, for tests for acceptance limits of error under other conditions, the limits of error set out in Column III of those tables shall apply.
- SOR/89-570, s. 6(F)
267 (1) Subject to subsections (4) and (5), the limits of error set out in the tables to subsections (2) and (3) apply to all positive displacement bulk volumetric liquid meters, including vehicle-mounted meters, that are designed to measure volumes of 180 litres or more or 40 gallons or more of heavy petroleum products, such as bunker oils, foodstuffs such as syrups, liquid cattle feed, fertilizers of high specific gravities or other liquids of high viscosity.
(2) The limits of error set out in the following table apply to meters, generally of a size 65 mm or 2½ inches or smaller, that are used to measure liquids of high viscosity:
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error 1 Any volume of 225 litres or more up to 900 litres or of 50 gallons or more up to 200 gallons ¼% of known test quantity ½% of known test quantity (3) The limits of error set out in the following table apply to meters, generally of a size 75 mm or three inches or larger, that are used to measure liquids of high viscosity:
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error 1 Any volume of 1 350 litres or more, or of 300 gallons or more 3/16% of known test quantity 3/8% of known test quantity (4) The acceptance and in-service limits of error set out in the tables to subsections (2) and (3) apply to known test quantities equal to or greater than quantities delivered by the meter in one minute at maximum operating rate.
(5) The acceptance limits of error set out in Column II of the tables to subsections (2) and (3) apply only to tests under controlled conditions such as bench tests, and for tests for acceptance limits of error under other conditions, the limits of error set out in Column III of those tables shall apply.
- SOR/89-570, s. 6(F)
268 (1) Subject to subsection (7), the limits of error set out in the tables to subsections (2) to (6) apply in respect of all meters that are designed to measure liquefied gases at ambient temperatures.
(2) The limits of error set out in the table to this subsection apply in respect of meters of a size from 25 mm to 50 mm or one inch to two inches, when tested using the liquefied gases the meters are intended to measure and using a narrow neck metal standard of the vapour displacement type.
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error Litres Gallons 1 225 or more 50 or more 0.5% of known test quantity 1% of known test quantity (3) The limits of error set out in the table to this subsection apply in respect of meters of a size 25 mm or larger or one inch or larger, except meters referred to in paragraph (4)(a), when tested using the liquefied gases the meters are intended to measure and using a pipe prover standard or master meter standard.
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error Litres Gallons 1 225 or more 50 or more 0.25% of known test quantity 0.5% of known test quantity (4) The limits of error set out in the table to this subsection apply in respect of
(a) meters used to dispense liquid propane to motor vehicles, when tested using the liquefied gases the meters are intended to measure and using a pipe prover standard or master meter standard; and
(b) meters of a size smaller than 25 mm or one inch, when tested using the liquefied gases the meters are intended to measure and using a pipe prover standard or master meter standard.
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error Litres Gallons 1 5 1 60 mL or 2 fluid ounces 120 mL or 4 fluid ounces 2 10 2 85 mL or 3 fluid ounces 170 mL or 6 fluid ounces 3 20 or more 4 or more 0.5% of known test quantity 1% of known test quantity
(5) The limits of error set out in the table to this subsection apply in respect of
(a) meters used to dispense liquid propane to motor vehicles, when tested using the liquefied gases the meters are intended to measure and using a gravimetric prover standard; and
(b) meters of a size smaller than 25 mm or one inch, when tested using the liquefied gases the meters are intended to measure and using a gravimetric prover standard.
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error Litres Gallons 1 from 25 to 45 from 5 to 10 1.5% 2% 2 more than 45 more than 10 0.8% 1%
(6) The limits of error set out in the table to this subsection apply in respect of meters of a size 25 mm or larger or one inch or larger, except meters referred to in paragraph (5)(a), when tested using the liquefied gases the meters are intended to measure and using a gravimetric prover standard.
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error Litres Gallons 1 from 100 to 200 from 20 to 45 0.75% 1% 2 more than 200 more than 45 0.75% 0.75% (7) The acceptance limits of error set out in Column II of the tables to subsections (2) to (6) apply only in respect of tests made under controlled conditions, and for tests made under other conditions the limits of error set out in Column III of those tables apply.
- SOR/89-570, s. 6(F)
- SOR/90-118, s. 36
269 (1) Subject to subsection (4), the limits of error set out in the tables to subsections (2) and (3) apply to all slow-flow meters rated at 115 litres per hour or less or 25 gallons per hour or less for use in trade in pipeline systems to measure fuel oil, stove oil or kerosene supplied to furnaces and other heating equipment, or in any other system where the meter is permanently connected to a point of fuel consumption.
(2) The limits of error set out in the following table apply to meters designed to operate at 2.25 to 22.5 litres or more per hour or 0.5 to five gallons or more per hour:
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error 1 Any volume above the minimum volume set out in specifications established by the Minister for slow-flow meters or for a design of slow-flow meter ½% of known test quantity ¾% of known test quantity (3) The limits of error set out in the following table apply to meters designed to operate at 0.10 to 3.4 litres or more per hour or 0.02 to 0.75 gallons or more per hour:
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error 1 Any volume above the minimum volume set out in specifications established by the Minister for slow-flow meters or for a design of slow-flow meter (during tests made at 0.5 litres per hour or 0.10 gallons per hour) 3% of known test quantity 4% of known test quantity 2 Any volume above the minimum volume set out in specifications established by the Minister for slow-flow meters or for a design of slow-flow meter (during tests made at 3.4 litres per hour or 0.75 gallons per hour) ½% of known test quantity ¾% of known test quantity (4) The limits of error set out in the tables to subsections (2) and (3) refer to the results of bench tests made in accordance with specifications established by the Minister for slow-flow meters.
- SOR/89-570, s. 6(F)
270 (1) In this section,
- API Gravity
API Gravity means the amount obtained using the following formula:
API Gravity = 141.5 ÷ (relative density 60/60°F) – 131.5;
(densité API)
- API Standard
API Standard means the Manual of Petroleum Measurement Standards, published by the American Petroleum Institute in August, 1980, with the designation “API, Standard 2540”; (norme API)
- ASTM
ASTM means the American Society for Testing and Materials; (ASTM)
- ASTM-IP
ASTM-IP means the American Society for Testing and Materials — Institute of Petroleum; (ASTM-IP)
- VCF
VCF means, in respect of a mechanical or electronic automatic temperature compensator, the applicable volume correction factor
(a) at the temperature of the measured liquid during each test of the compensator, in the column corresponding to the density at 15°C in kilograms per cubic metre for which the compensator is marked or adjusted, or to the density corresponding to the cubical coefficient of thermal expansion, relative density or API gravity for which the compensator is marked or adjusted, that is set out
(i) in the case of natural crude oil, in Table 54A of the API Standard,
(ii) in the case of generalized liquid petroleum products, in Table 54B of the API Standard, and
(iii) in the case of lubricating oils, in Table 54D of the API Standard,
(b) at the temperature of the measured liquid during each test of the compensator, in the column corresponding to the agreed or experimentally determined cubical coefficient of thermal expansion at 15°C for that liquid and for which the compensator is marked or adjusted, that is set out, in the case of special petroleum liquids to which Tables 54A, 54B and 54D of the API Standard are not applicable, in Table 54C of the API Standard, or
(c) at the temperature of the measured liquid during each test of the compensator, in the column corresponding to the density at 15°C in grams per litre for which the compensator is marked or adjusted, or to the density corresponding to the cubical coefficient of thermal expansion, relative density or API gravity for which the compensator is marked or adjusted, that is set out, in the case of liquefied petroleum gases, natural gas liquids and asphalts, in Table 54 of the ASTM-IP Petroleum Measurement Tables, with designation ASTM D1250, 1953 Metric Edition. (FCV)
(2) Subject to subsections (4) to (6), the limits of error set out in the table to this subsection apply in respect of mechanical automatic temperature compensators used in conjunction with meters in the measurement of liquids.
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error 1 Test volume shall be in accordance with specifications established pursuant to section 13 for mechanical automatic temperature compensators for use with any device or class, type or design of device The ratio NET/GROSS shall lie in the range from (VCF-0.0010
-0.00018ΔT)
to
(VCF+0.0010
+0.00009ΔT)
The ratio NET/GROSS shall lie in the range from (VCF-0.0020
-0.00036ΔT)
to
(VCF+0.0020
+0.00018ΔT)
(3) In the table to subsection (2) and in subsections (5) and (7),
(a) NET is the corrected registration of the register and GROSS is the uncorrected registration of the register; and
(b) ΔT is the difference in degrees Celsius
(i) between the test temperature and 15°C where the compensator is used with a meter designed to measure liquids at ambient temperature, or
(ii) between the test temperature and the mid-range temperature of the compensator, where the compensator is used with a meter designed to measure liquids at temperatures other than ambient temperature, and for the purposes of calculating the limits of error, “ΔT” shall not exceed 15°C except in the case of a compensator used with a meter designed to measure liquids at ambient temperature.
(4) The acceptance limits of error set out in Column II of the table to subsection (2) apply only to tests made under controlled conditions, and for tests made under other conditions the limits of error set out in Column III of that table apply.
(5) In addition to being within applicable limits of error, the NET/GROSS ratios shall agree within 0.001 on at least two of three consecutive tests at the same temperature under controlled conditions.
(6) The limits of error for mechanical automatic temperature compensators submitted for approval pursuant to section 3 of the Act shall be one half the limits of error set out in the table to subsection (2).
(7) The limits of error set out in the table to this subsection apply in respect of electronic automatic temperature compensators used in conjunction with meters in the measurement of liquids.
Column I Column II Column III Item Known Test Quantity Acceptance Limits of Error In-Service Limits of Error 1 Test volume shall be in accordance with specifications established pursuant to section 13 for electronic automatic temperature compensators for use with any device or class, type or design of device The VCF applied to the gross registration shall be not more than the VCF corresponding to a temperature that is 0.5°C less than the test temperature, and not less than the VCF corresponding to a temperature that is 0.5°C more than the test temperature The VCF applied to the gross registration shall be not more than the VCF corresponding to a temperature that is 1°C less than the test temperature, and not less than the VCF corresponding to a temperature that is 1°C more than the test temperature (8) Where an automatic temperature compensator referred to in subsection (7) is not marked as described in the definition VCF in subsection (1), the printed ticket, card, bill of lading or other printed record of a transaction shall specify the density, relative density, API gravity or cubical coefficient of thermal expansion, as appropriate, for which the compensator is adjusted, for each delivery by the meter.
- SOR/89-570, s. 6(F)
- SOR/90-118, s. 37
- SOR/2005-297, s. 20
Installation and Use
271 A meter shall be properly suited to the particular installation in which it is to be used, with respect to pressure, rate of flow, temperature, compatibility with the characteristics of the liquid to be measured and method of use so that, for all normally occurring variations in operating conditions, measurement by the meter remains within the applicable limits of error.
- SOR/89-570, s. 6(F)
272 The equipment and accessories installed with a meter shall be selected and installed so as to minimize their interference with the proper operation and accuracy of measurement of the meter.
273 The pump suction piping installed with a meter shall be as short and unencumbered as possible and all liquid supply systems associated with a meter shall be arranged to minimize the ingress of air, water or other foreign matter, including any liquid other than the one the meter is intended to measure.
274 A meter and all equipment and accessories associated with it in an installation shall be installed so as to minimize the evolution of dissolved air and gases and to minimize the vaporization of the liquid prior to or during measurement or in the delivery conduit.
275 (1) A meter shall be installed so that it can only be operated when the liquid in the meter is at or above atmospheric pressure, and in any installation where the liquid pressure could fall below atmospheric pressure, a suitable vacuum breaker shall be installed at the outlet of the meter.
(2) A meter shall be operated only when the liquid in the meter is at or above atmospheric pressure.
276 When a meter is installed in a measuring system, the system shall be equipped with effective automatic means to minimize the passage of air or vapour through the meter.
277 A meter shall have installed immediately upstream therefrom a screen, strainer, filter, integral filter or such other approved means as will prevent foreign matter from passing through the meter.
278 For the purposes of sections 276 and 277, a close-coupled strainer and automatic air release valve is sufficient in meter installations where only free air or vapour is to be removed from the liquid.
279 The air or vapour eliminator installed with a meter shall minimize the passage of air or vapour through the measuring element of the meter when the supply of liquid is exhausted or appropriate means shall be provided to automatically stop the flow of liquid or to indicate to the person using the meter that air or vapour is passing through the meter.
280 Sealed flow control valves or other means shall be installed with a meter to limit the flow through the meter to its rated maximum flow.
281 Unless a meter is equipped with a reversing register and totalizer in accordance with section 250, it shall be installed so as to minimize any reverse flow through it or the piping or equipment upstream or downstream from it that could affect the accuracy of its measurement.
282 (1) In this section, transfer point means the fixed point in a measuring assembly where transfer of possession of a quantity of liquid contained in the measuring assembly takes place.
(2) A meter shall be installed so that the piping between the meter and the transfer point remains full of liquid during and after a transaction unless the liquid, because of its nature, cannot remain in the meter, and
(a) in the case of a meter installed to deliver a quantity of liquid, so that the piping downstream of the transfer point shall empty at the completion of the transaction; and
(b) in the case of a meter installed to receive a quantity of liquid, so that the piping upstream of the transfer point shall empty at the completion of the transaction.
(3) Subject to section 289 and except as otherwise allowed by any additional specifications established pursuant to section 27, a meter shall be installed
(a) so that all piping downstream of the meter, where the meter is installed to deliver a quantity of liquid, or all piping upstream of the meter, where the meter is installed to receive a quantity of liquid, may be readily inspected; and
(b) with only one delivery outlet unless the meter is installed
(i) so that diversion of flow is readily apparent to the purchaser or the purchaser’s agent by automatic means such as visible valves or lights with explanatory signs that indicate which outlets are in operation,
(ii) to fuel or defuel aircraft, or
(iii) to be used exclusively to load vehicle-mounted propane tanks with a capacity greater than 5 000 L.
- SOR/90-118, s. 38
283 A meter, other than a slow-flow meter, slow-flow dispenser, dispenser of the service station type for motor fuel or a meter equipped with a preset valve, shall have a quick-acting valve installed near its outlet for inspection purposes.
- SOR/93-234, s. 2(F)
284 A meter, other than a slow-flow meter, shall be installed so that it has a convenient means for delivering the measured product when the meter installation is tested and inspected.
285 Any automatic valve that can have a throttling effect on the flow of liquid shall be installed downstream from the meter.
286 (1) Unless otherwise authorized by specifications established by the Minister, the outlet end of the delivery hose of a pump-supplied meter shall be equipped with a spring-loaded anti-drain valve or its equivalent.
(2) Subsection (1) does not apply to a meter with collapsible hoses used on aircraft refuellers or to a meter designed for defuelling aircraft.
287 The discharge hose installed with a meter supplied by gravity head may be of the dry hose type without a shut-off valve at the discharge end, but it shall be of such length, size and stiffness as to ensure complete drainage and there shall be means provided in the meter system to show the empty condition of the hose and to prevent the meter from draining.
288 Where it is necessary
(a) to limit changes in the viscosity of, or the solubility of material dissolved in, the liquid to be measured by the meter, or
(b) to limit the rate of change of the temperature or pressure of the liquid to be measured by the meter when the meter is equipped with an automatic compensator,
appropriate automatic controls shall be installed in the meter system to permit the meter to measure accurately.
- SOR/90-118, s. 39
289 (1) The piping on the downstream side of meters may be concealed and the outlets interconnected where the meters
(a) are used
(i) at pipeline terminals, or
(ii) exclusively for loading or unloading railway tank cars or loading or unloading tanker ships; and
(b) have adequately interlocked manual or automatic valves with means for leakage detection incorporated in the meter systems to prevent the diversion of measured liquid.
(2) The piping on the downstream side of the meters may be concealed where the meters have more than one outlet and are used exclusively for refuelling trucks.
- SOR/2005-297, s. 21
290 A meter shall be operated only at flow rates between the rated minimum and maximum flow rates marked on the name plate of the meter.
291 If any part of a meter system is drained for any reason the entire system shall be re-primed and re-filled and the register set to zero before the meter is used for the next measurement.
292 A flow transmitter for input to an electronic data processing system may be attached to a liquid meter and the output from the data processing system used for invoicing purposes if the purchaser of the liquid being measured or his agent is given a printed copy of the data recorded by the data processing system before he leaves the trader’s premises.
293 A flow transmitter may be installed at a key-operated self-service meter installation to drive the unverified accumulative totalizers for individual customers if the purchaser of the liquid being measured is able to visually check the advance of his totalizer against the indication of the primary indicator at the time of delivery of the liquid.
294 Where a meter mounted on a vehicle tank is used in circumstances where the purchaser does not normally view the meter during delivery of a liquid, the meter shall be equipped with an interlocked ticket printer that shall be used for each delivery of the liquid.
295 Tickets used with a meter equipped with an automatic temperature or other compensator shall bear statements that the volume indicated thereon has been adjusted to correspond to an equivalent volume at a standard condition stated on the ticket.
DIVISION XIIMeasuring and Vehicle Tanks
Interpretation
296 In this Division,
- tank
tank [Revoked, SOR/90-118, s. 40]
- vehicle tank
vehicle tank means a measuring tank that is mounted on a vehicle other than a vehicle for railway use. (réservoir sur véhicule)
- SOR/90-118, s. 40
Design, Composition and Construction
297 A tank and its piping system and any equipment or accessories that can affect its accuracy of measurement shall be of such design, composition and construction that when a delivery is made from any capacity indication, the quantity of liquid delivered through any discharge valve rigidly connected to the tank is within the prescribed limits of error for the tank.
- SOR/89-570, s. 6(F)
298 The shells or bulkheads of a tank shall consist of such material and be so constructed that they will not become distorted under any condition of loading under normal conditions of use.
299 A tank shall have an effective means of automatic venting to permit the free passage of air into and out of the tank when it is emptied and filled.
300 Subject to section 320, there shall be no pipe or other flow connection between two or more tanks that are separately calibrated, but a battery of calibrated tanks may be connected to a common discharge manifold that prevents flow from one tank to another.
301 The capacity indicators on a tank shall consist of
(a) graduations on or adjacent to a gauge glass or tube; or
(b) appropriate internal capacity indicators.
- SOR/93-234, s. 2
302 A capacity indicator shall only be installed in a tank at any level where a quantity of liquid equal to the limit of error referred to in section 325 for the indicated quantity causes the liquid at that level to rise by at least 2.5 mm or 3/32 of an inch.
- SOR/89-570, s. 6(F)
- SOR/90-118, s. 41
303 A maximum capacity indicator shall be positioned to allow a volume equal to at least one per cent of the capacity of the tank for the thermal expansion of the liquid.
304 When an internal capacity indicator is installed in a tank,
(a) the indicator shall be attached to a permanent section of the tank; and
(b) a means shall be provided to attach a seal on the indicator.
- SOR/93-234, s. 2
- SOR/94-691, s. 4
305 A tank equipped with an internal capacity indicator shall have a suitable opening for the convenient installation, adjustment and sealing of the indicator assembly and the capacity indicator shall be located so that it can be seen under normal conditions of use.
306 Gauge glass fittings shall not, except on tanks for liquefied gases, be of the ball check type or be of any type designed to prevent loss of liquid in case of glass breakage, but a bottom gauge glass fitting may include an emergency valve if means are provided thereon to allow an inspector to seal the valve in the open position.
307 The discharge hose on a tank that discharges by gravity shall normally be of the dry hose type, without a shut-off valve at its discharge end, shall be of such length, size and stiffness as will ensure its complete drainage and shall be provided with a means to indicate when all of the measured liquid has been delivered thereby.
308 (1) A tank that discharges through a pump shall have an automatic means of ensuring that
(a) the quantity of liquid in the pump suction and discharge lines remains constant; and
(b) all the measured liquid is delivered through the pump.
(2) Subsection (1) does not apply to a tank used for bunker oils and similar liquids.
309 A fixed tank shall have suitably installed and identified levelling ledges that will permit the detection of any tilting of the tank from the position in which it was calibrated.
310 (1) A portable tank shall be equipped with permanent level gauges to enable it to be levelled for inspection and use.
(2) A portable tank with a gauge glass shall be equipped with levelling jacks to enable it to be levelled for inspection and use.
- SOR/93-234, s. 2(F)
311 A vehicle tank shall be designed so as to permit the complete discharge of the contents of the tank and piping when the vehicle is on a surface that is within three degrees of level or shall be equipped with clearly defined and appropriately located means to indicate when an off-level position will prevent the tank and the piping from filling or draining properly.
312 An internal capacity indicator on a vehicle tank shall be centrally located in the tank or compartment, affixed to a mounting bracket on the dome neck by brazing, welding or bolts and shall be sealable.
313 When two or more capacity indicators on a vehicle tank are affixed to a mounting bracket, the bracket shall be held in a vertical position by a suitable brace or other reinforcement.
314 Internal capacity indicators on a vehicle tank shall be adjustable in increments of 0.8 mm or 1/32 inch or less.
315 When a vehicle tank is composed of two or more separate measuring compartments, any space between the compartments shall be equipped with drains capable of indicating leakage into the space.
316 The outlet piping from a vehicle tank may be split into a bottom-fill connection and a drain connection, but where the bottom loading stub can trap air in excess of 0.125 per cent of the capacity of the tank to the lowest marker when the tank is filled from the top, the tank shall be calibrated for top-fill.
317 (1) Subject to subsection (2), a common manifold connected to a vehicle tank may be split into two sections separated by means of a valve if the valve is designed so that it cannot be left in any open position.
(2) A gate valve may be used in place of the valve referred to in subsection (1) if the volume that can be diverted by leaving the gate valve open does not exceed 0.125 per cent of the capacity of the smallest tank connected to the manifold.
318 [Revoked, SOR/93-234, s. 2]
319 The piping on a vehicle tank restricted for use with bunker oil may be concealed by insulation or by parts of the tank to prevent the bunker oil from congealing.
320 Individual compartments on a vehicle tank restricted for use with bunker oil may be connected to a common discharge manifold without any automatic means of preventing flow between the compartments.
Performance
321 A tank shall be tested and calibrated with a liquid that has a thermal expansion coefficient, volatility and viscosity not greater than that of domestic furnace fuel oil and that will not have a corrosive effect on the tank.
322 A tank shall be tested and calibrated when all necessary supports have been installed and it is resting in the position in which it is designed to be used.
323 A tank, other than a vehicle tank, shall be calibrated to a valve immediately adjacent to the outlet connection on the tank.
324 Unless otherwise authorized by specifications established by the Minister, a tank that has a gauge glass or a slip type gauge shall not be calibrated for a delivery of less than 50 per cent of the tank capacity.
325 (1) Subject to subsection (5), when a tank is tested for acceptance limits of error using a known test volume determined in relation to a relevant local standard and set out in Column I of an item of a table to subsection (3) or (4), the tank is within the acceptance limits of error in respect of that known test volume if the actual volume of the tank
(a) does not exceed the test volume by an amount in excess of the amount set out in Column II of that item; and
(b) is not less than the test volume by an amount in excess of the amount set out in Column II of that item.
(2) Subject to subsection (5), when a tank is tested for in-service limits of error using a known test volume determined in relation to a relevant local standard and set out in Column I of an item of a table to subsection (3) or (4), the tank is within the in-service limits of error in respect of that known test volume if the actual volume of the tank
(a) does not exceed the test volume by an amount in excess of the amount set out in Column III of that item; and
(b) is not less than the test volume by an amount in excess of the amount set out in Column III of that item.
(3) Subject to subsection (5), the limits of error set out in the following table apply to all measuring tanks whether fixed, portable or vehicle mounted, that are calibrated in terms of metric units of volume:
Item Column I Column II Column III Known Test Volume Acceptance Limits of Error In-Service Limits of Error Litres Millilitres Millilitres 1 50 185 185 2 100 300 300 3 200 500 500 4 Over 200 ¼% of known test volume ¼% of known test volume (4) Subject to subsection (5), the limits of error set out in the following table apply to all measuring tanks whether fixed, portable or vehicle mounted, that are calibrated in terms of Canadian units of volume:
Item Column I Column II Column III Known Test Volume Acceptance Limits of Error In-Service Limits of Error Gallons Fluid Ounces Fluid Ounces 1 10 6 6 2 20 10 10 3 50 20 20 4 Over 50 ¼% of known test volume ¼% of known test volume (5) The limits of error for a tank that is designed for use in measuring liquefied gases are twice the applicable limits of error set out in the table to subsection (3) or (4).
(6) The limits of error set out in the tables to subsections (3) and (4) refer to the total inaccuracy of measurement by the tank, including errors due to entrapment of air or liquid by parts of the tank or its associated piping, equipment or accessories during filling or emptying.
- SOR/89-570, s. 6(F)
- SOR/94-691, s. 4(E)
326 A vehicle tank shall be tested to ensure that air or liquid is not trapped therein in excess of 0.125 per cent of the capacity of the tank under conditions of normal use.
Installation and Use
327 A fixed tank shall be installed on substantial supports adequate to ensure that the position of the tank remains constant and level with reference to the levelling ledges.
328 A fixed tank shall be level when filled, as shown by the levels installed on the tank or levelling ledges, and when in use, a portable or vehicle tank shall be filled and emptied when it is as close to level conditions as practicable.
329 When a tank is being filled, care shall be taken to minimize the possibility of air being trapped in the piping or entrained in the liquid.
330 A tank shall not be used for deliveries of quantities between internal capacity indicators.
331 A vehicle tank not equipped with level gauges shall, when being used to measure, be on a surface that is within three degrees of level.
332 A vehicle tank that is equipped with level gauges shall, when being used to measure, be level within the limits marked on the level gauges.
333 A vehicle tank shall be supported in a manner that will not distort the tank when the vehicle is driven under conditions of normal use.
334 If emergency valves are installed on a vehicle tank calibrated with wet lines, they shall be open when the tank is being filled.
PART VIAuthorization of Use of Units of Measurement
335 The units of measurement described in Column I of an item in the following table and defined in Column II of that item may be used for the particular purpose described in Column III of that item:
Item | Column I | Column II | Column III |
---|---|---|---|
Unit of Measurement | Definition | Particular Purpose | |
1 | hectolitre | 100 litres | measuring volumes of grain as defined in the Canada Grain Act |
2 | becquerel | one nuclear transformation per second | measuring activity of radionuclides |
3 | gray | one joule per second | measuring absorbed dose of ionizing radiation in any medium |
4 | sievert | dose equivalent to one joule per kilogram | measuring the biological effect in tissue of a given absorbed dose, for radiation protection purposes |
5 | nautical mile | 1852 metres | measuring distance in marine and air navigation and in defining marine limits |
6 | knot | 1 nautical mile per hour | measuring speed in marine and air navigation and in marine and air weather forecasting |
7 | Cord | 128 cubic feet of stacked roundwood (whole or split, with or without bark) containing wood and airspace with all bolts of similar length piled in a regular manner with their longitudinal axes approximately parallel | measuring stacked roundwood |
8 | stacked cubic metre | 1 cubic metre of stacked roundwood (whole or split, with or without bark) containing wood and airspace with all bolts of similar length piled in a regular manner with their longitudinal axes approximately parallel | measuring stacked roundwood |
- SOR/78-623, s. 1
- SOR/86-855, s. 1
- SOR/93-234, s. 2
PART VIIMetric Conversion
DIVISION 1Retailing of Gasoline and Diesel Fuel
336 (1) In this Division, meter means a volumetric liquid measuring machine for use in the retail trade of gasoline or diesel fuel.
(2) Subject to subsections (3), (4), (5) and (7), only the unit of measurement set out in column I of an item in the following table shall be used for offering, advertising or displaying gasoline or diesel fuel for retail trade in terms of the price per unit of measurement during the period of time set out in column II of that item:
Item Column I Column II Unit of Measurement Period of Time 1 gallon up to and including December 31, 1978 2 gallon or litre from January 1, 1979 to December 31, 1980 inclusive 3 litre on and after January 1, 1981 (3) On the coming into force of this Part, any retail outlet may continue to offer, advertise or display gasoline or diesel fuel by the litre if it did so prior to the coming into force of this Part.
(4) Up to and including December 31, 1980, where a price per unit of measurement of gasoline or diesel fuel is displayed in a meter, the half-gallon may be the unit of measurement so displayed in the meter if
(a) the price of the commodity exceeds 99.9 cents per gallon; and
(b) when the monetary value shown on the meter at the end of each transaction is multiplied by a factor of 2, the total price to be paid is in mathematical agreement with the quantity indication and unit price.
(5) A retail outlet
(a) situated outside a metropolitan government area, city, town or other urban municipality, and
(b) serving a sparsely populated area
may, during 1981 or any year thereafter, continue to
(c) offer, advertise or display gasoline or diesel fuel for retail trade by the gallon, or
(d) where a price per unit of measurement of gasoline or diesel fuel is displayed in a meter, display in the meter the half-gallon as that unit of measurement provided the conditions of paragraphs (4)(a) and (b) are met
if, in the preceding year, total retail sales of gasoline and diesel fuel of that retail outlet did not exceed 100,000 gallons.
(6) The mathematical agreement requirement of section 140 and the unit price display requirement of section 253 do not apply to a meter where a price per half-gallon is displayed in the meter and the requirements of subsection (4) or (5), whichever is applicable, are met.
(7) Where, pursuant to subsection (4) or (5), whichever is applicable, the price displayed in a meter is a price per half-gallon, the gallon shall be the unit of measurement used by that retail outlet for otherwise offering, advertising or displaying gasoline or diesel fuel for retail trade.
- SOR/78-152, s. 1
- SOR/79-390, s. 2(E)
DIVISION 2Retailing of Individually Measured Foods and Scale Conversion
337 (1) In this Division,
- area
area means a geographic area, as it existed on October 1, 1978, described in column I of an item of the table to section 341 and includes any city, town, municipality or unorganized region geographically situated totally or partially in such area; (régions)
- commodity
commodity means a commodity in respect of which this Division applies; (marchandise)
- individually measured commodity
individually measured commodity has the meaning set out in section 45. (marchandise mesurée individuellement)
(2) This Division applies in respect of any food that is an individually measured commodity, including, without restricting the generality of the foregoing, meat, fish, cheese, produce, nuts, candy and confections.
- SOR/79-390, s. 3
- SOR/80-83, s. 1
- SOR/81-495, s. 1
338 (1) Subject to subsection (2) and section 340, in each area described in column I of an item of the table to section 341, on and after the date set out in column II of that item, only metric units of measurement shall be used for advertising a commodity for retail trade in terms of price per unit of measurement.
(2) In each area described in column I of an item of the table to section 341, during the periods commencing on the dates set out in column II of that item and ending on December 31, 1985, a Canadian unit of measurement may be used for advertising a commodity for retail trade in terms of price per unit of measurement if the equivalent price per metric unit of measurement is shown in a manner more prominent than the Canadian unit of measurement.
- SOR/79-390, s. 3
- SOR/80-83, s. 2
- SOR/81-495, s. 2
- SOR/84-397, s. 1
339 Subject to section 340, in each area described in column I of an item of the table to section 341, on and after the date set out in column III of that item, no device shall be used in the retail trade of a commodity unless it is capable of weighing or measuring in terms of metric units of measurement.
- SOR/79-390, s. 3
- SOR/80-83, s. 2
- SOR/81-495, s. 2
340 No metric unit of measurement of mass or weight or any multiple or subdivision thereof shall be used for offering, advertising or displaying a commodity for retail trade in terms of price per unit of measurement other than the unit or subdivision thereof set out in the following expressions:
(a) price per kilogram; or
(b) price per one hundred grams.
- SOR/79-390, s. 3
341 Subject to subsection 338(2), in each area described in column I of an item of the following table, on and after the date set out in column III of that item, Canadian units of measurement shall not be used in the retail trade of a commodity:
Column I | Column II | Column III | |
---|---|---|---|
Item | Area | Date | Date |
NF1 | In the Province of Newfoundland, the Provincial Electoral Districts of St. John’s East, St. John’s North, St. John’s Centre, St. John’s South, St. John’s West, St. John’s East Extern, Mount Scio, Kilbride, Mount Pearl and Pleasantville. | Jan. 4, 1982 | June 30, 1982 |
NF2 | In the Province of Newfoundland, the Avalon Peninsula, including Come-by-Chance and Sunnyside but excluding area NF1. | July 5, 1982 | Dec. 31, 1982 |
NF3 | In the Province of Newfoundland, the Provincial Electoral Districts of Fogo, Bonavista North, Terra Nova, Bonavista South, Trinity North, Burin-Placentia West, Grand Bank and Fortune-Hermitage and that part of the Provincial Electoral District of Bellevue not included in area NF2. | Jan. 3, 1983 | Feb. 28, 1983 |
NS1 | In the Province of Nova Scotia, the County of Halifax. | Jan. 11, 1982 | March 30, 1982 |
NS2 | In the Province of Nova Scotia, the Counties of Colchester, Cumberland, Annapolis, King’s and Yarmouth and the Districts of East Hants, West Hants, Digby, Clare and Argyle. | April 5, 1982 | June 30, 1982 |
NS3 | In the Province of Nova Scotia, the County of Queen’s and the Districts of Barrington, Shelburne, Lunenburg and Chester. | July 5, 1982 | July 31, 1982 |
NS4 | In the Province of Nova Scotia, the Counties of Pictou, and Antigonish and the Districts of Guysborough and St. Mary’s. | Aug. 2, 1982 | Aug. 31, 1982 |
NS5 | In the Province of Nova Scotia, Cape Breton Island. | Sept. 6, 1982 | Oct. 31, 1982 |
NB1 | In the Province of New Brunswick, the Counties of Saint John and King’s. | Jan. 11, 1982 | March 31, 1982 |
NB2 | In the Province of New Brunswick, the Counties of Albert and Westmorland. | April 5, 1982 | June 30, 1982 |
NB3 | In the Province of New Brunswick, the Counties of Queen’s, Charlotte, Sunbury, York, Carleton, Victoria, Madawaska, Restigouche, Gloucester, Northumberland and Kent. | July 5, 1982 | Oct. 31, 1982 |
PEI | The Province of Prince Edward Island. | April 5, 1982 | June 30, 1982 |
Q1 | In the Province of Quebec, the Urban Community of Quebec and that part of the County of Quebec to the south of parc des Laurentides and the Ste-Anne River. | Jan. 4, 1982 | May 31, 1982 |
Q2 | In the Province of Quebec, the Counties of Lévis, Beauce, Dorchester, Mégantic and Lotbinière. | April 5, 1982 | July 31, 1982 |
Q3 | In the Province of Quebec, the Counties of Bellechasse, Montmagny, L’Islet, Kamouraska, Rivière-du-Loup and Témiscouata. | July 5, 1982 | Sept. 30, 1982 |
Q4 | In the Province of Quebec, the Counties of Portneuf, Montmorency 1, Montmorency 2, West Charlevoix and East Charlevoix and that part of the County of Quebec not included in area Q1. | Oct. 4, 1982 | Nov. 30, 1982 |
Q5 | In the Province of Quebec, the Counties of Lac St-Jean East, Lac St-Jean West, Chicoutimi and Saguenay. | Sept. 6, 1982 | March 31, 1983 |
Q6 | In the Province of Quebec, the Counties of Rimouski, Matapédia, Matane, Gaspé West, Gaspé East and Bonaventure and the Îles-de-la-Madeleine. | April 4, 1983 | Sept. 30, 1983 |
TR1 | In the Province of Quebec, the southern part of the Counties of St. Maurice and Champlain, along and within 20 km of the St. Lawrence River and east of the Yamachiche River. | Jan. 4, 1982 | March 31, 1982 |
TR2 | In the Province of Quebec, those parts of the Counties of St. Maurice and Champlain south of the 47th parallel of latitude, excluding area TR1 and the southern part of the County of St. Maurice lying west of the Yamachiche River within 25 km of the St. Lawrence River. | April 5, 1982 | June 30, 1982 |
TR3 | In the Province of Quebec, the Counties of Nicolet and Yamaska. | July 5, 1982 | Sept. 30, 1982 |
TR4 | In the Province of Quebec, the Counties of Berthier and Maskinongé, and those parts of the County of St. Maurice and Champlain not included in Area TR1 or TR2. | Oct. 4, 1982 | Dec. 31, 1982 |
SH1 | In the Province of Quebec, the County of Sherbrooke. | Jan. 4, 1982 | March 31, 1982 |
SH2 | In the Province of Quebec, the Counties of Compton, Richmond, Stanstead and Wolfe. | Jan. 4, 1982 | March 31, 1982 |
SH3 | In the province of Quebec, the County of Shefford. | April 5, 1982 | May 31, 1982 |
SH4 | In the Province of Quebec, the Counties of Arthabaska and Drummond. | May 31, 1982 | Aug. 31, 1982 |
SH5 | In the Province of Quebec, the Counties of Brome, Missisquoi and Frontenac. | Sept. 6, 1982 | Oct. 31, 1982 |
M1 | In the Province of Quebec, that part of the Island of Montreal west of Boulevard Laurentien and Autoroute Décarie and north of the Lachine Canal and that part of the Island of Montreal bounded on the west by the Cities of Montréal-Nord and Saint-Léonard and the Boulevard Métropolitain and the Boulevard Louis-Hippolyte-Lafontaine. | Jan. 4, 1982 | March 8, 1982 |
M2 | In the Province of Quebec, Île-Jésus, the Cities of Montréal-Nord and Saint-Léonard, that part of the City of Saint-Laurent to the east of Boulevard Laurentien and that part of the City of Montréal to the north of Boulevard Métropolitain and to the east of Boulevard Laurentien. | March 8, 1982 | April 26, 1982 |
M3 | In the Province of Quebec, that part of the Island of Montreal bounded by Boulevard Métropolitain to the north, Autoroute Décarie to the west, the Lachine Canal to the south and St. Pierre Street, Bleury Street, Park Avenue and the eastern limits of the City of Outremont and the Town of Mont-Royal to the east. | April 26, 1982 | June 21, 1982 |
M4 | In the Province of Quebec, that part of the City of Montreal between Boulevard Métropolitain to the north, Boulevard Louis-Hippolyte-Lafontaine to the east, the St. Lawrence River to the south and Saint-Pierre Street, Bleury Street and Park Avenue and the eastern municipal limits of Outremont and Mont-Royal to the west. | June 21, 1982 | Aug. 31, 1982 |
M5 | In the Province of Quebec, the Cities of LaSalle and Verdun and that part of the City of Montreal south of the Lachine Canal. | Aug. 30, 1982 | Sept. 27, 1982 |
M6 | In the Province of Quebec, the Counties of Verchères, La Prairie, Châteauguay and Beauharnois and that part of the Administrative Region of Montreal formerly known as the County of Chambly. | Sept. 27, 1982 | Nov. 15, 1982 |
M7 | In the Province of Quebec, the Counties of Soulanges, Vaudreuil, Deux-Montagnes and Argenteuil. | Nov. 15, 1982 | Dec. 13, 1982 |
M8 | In the Province of Quebec, the Counties of Richelieu, St-Hyacinthe, Bagot, Rouville, St-Jean, Napierville, Iberville and Huntingdon. | Jan. 10, 1983 | Feb. 21, 1983 |
M9 | In the Province of Quebec, the Counties of Joliette, Montcalm, L’Assomption and Terrebonne and the County of Labelle excluding the Cantons of Blake, Bigelow and Wells. | Feb. 21, 1983 | April 18, 1983 |
M10 | In the Province of Quebec, the Counties of Abitibi and Temiscamingue and that part of the Counties of Pontiac and Gatineau to the north of the 47th parallel of latitude. | April 4, 1983 | June 30, 1983 |
OT1 | In the Province of Ontario, the Regional Municipality of Ottawa-Carleton and in the Province of Quebec, the Regional Community of Outaouais. | Jan. 4, 1982 | July 31, 1982 |
OT2 | In the Province of Ontario, the County of Renfrew. | Aug. 2, 1982 | Sept. 30, 1982 |
OT3 | In the Province of Ontario, the County of Lanark and the United Counties of Leeds and Grenville, excluding the Townships of Front of Leeds and Lansdowne, Rear of Leeds and Lansdowne, North Crosby and South Crosby. | Oct. 4, 1982 | Nov. 30, 1982 |
OT4 | In the Province of Ontario, the United Counties of Prescott and Russell, and of Glengarry, Stormont and Dundas. | Dec. 6, 1982 | Jan. 31, 1983 |
OT5 | In the Province of Quebec, that part of the Counties of Pontiac and Gatineau south of the 47th parallel of latitude, the Cantons of Blake, Bigelow and Wells in the County of Labelle and that part of the County of Papineau not included in area OT1. | Jan. 31, 1983 | June 30, 1983 |
B1 | In the Province of Ontario, in the County of Lennox and Addington, the Townships of Richmond, Camden East, North Fredericksburgh, South Fredericksburgh, Adolphus Town, Ernestown and Amherst Island, including the Town of Napanee and the Villages of Bath and Newburgh; in the County of Frontenac, the Townships of Portland, Loughborough, Storrington, Kingston, Pittsburgh, Howe Island and Wolfe Island, including the City of Kingston; and in the United Counties of Leeds and Grenville, the Townships of Front of Leeds and Lansdowne, and Rear of Leeds and Lansdowne, including the separated Town of Gananoque. | Jan. 4, 1982 | March 31, 1982 |
B2 | In the Province of Ontario, the County of Prince Edward; in the County of Northumberland, the Townships of Murray, Brighton Cramahe, Haldimand, Hamilton and Hope, including the Towns and Villages of Cobourg, Port Hope, Colborne and Brighton; in the County of Hastings, the Townships of Sidney, Thurlow and Tyendinaga, including the Town of Deseronto, the Village of Frankford, the separated Town of Trenton and the City of Belleville. | April 5, 1982 | May 31, 1982 |
B3 | In the Province of Ontario, that part of the County of Hastings lying north of the Townships of Sidney, Thurlow and Tyendinaga, including the Villages of Bancroft, Deloro, Madoc, Marmora, Stirling and Tweed; that part of the County of Frontenac lying north of the Townships of Portland, Loughborough and Storrington; in the United Counties of Leeds and Grenville, the Townships of North Crosby and South Crosby, including the Villages of Westport and Newboro; and that part of the County of Lennox and Addington lying north of the Township of Camden East. | May 31, 1982 | Aug. 31, 1982 |
B4 | In the Province of Ontario, the Provisional County of Haliburton and the District Municipality of Muskoka; in the District of Nipissing, the organized and unorganized Townships of Finlayson, Peck, Canisbay, Sproule, Preston, Clancy, Airy, Murchison, Dickens, Sabine and Lyell. | Sept. 6, 1982 | Nov. 30, 1982 |
B5 | In the Province of Ontario, the County of Victoria; the County of Peterborough, including the City of Peterborough; in the County of Northumberland, the Townships of Alnwick, Percy and Seymour, including the Towns and Villages of Campbellford and Hastings. | Jan. 3, 1983 | March 31, 1983 |
T1 | In the Province of Ontario, the City of Brampton in the Regional Municipality of Peel and the Regional Municipality of Halton, excluding the City of Burlington. | Jan. 4, 1982 | Feb. 28, 1982 |
T2 | In the Province of Ontario, the City of Mississauga. | March 1, 1982 | April 30, 1982 |
T3 | In the Province of Ontario, that part of the Borough of Etobicoke lying south of Highway 401. | May 3, 1982 | June 30, 1982 |
T4 | In the Province of Ontario, the Borough of York and that part of the Boroughs of North York and the City of Toronto, bounded by Highway 401 in the north, and by University and Avenue Roads in the east. | Sept. 6, 1982 | Nov. 30, 1982 |
T5 | In the Province of Ontario, those parts of the Boroughs of North York and East York and of the City of Toronto, including Centre Island, bounded by Highway 401 in the north, and including and bounded by University and Avenue Roads in the west, and Don Valley Parkway in the east. | May 3, 1982 | June 30, 1982 |
T6 | In the Province of Ontario, the northern parts of the Boroughs of Etobicoke and North York, bounded on the south by Highway 401 and on the east by the Don Valley Parkway. | July 5, 1982 | Aug. 31, 1982 |
T7 | In the Province of Ontario, the Borough of Scarborough and the eastern part of the Boroughs of North York and East York and the City of Toronto, bounded on the west by the Don Valley Parkway. | March 1, 1982 | April 30, 1982 |
T8 | In the Province of Ontario, the Regional Municipality of Durham, excluding the Townships of Uxbridge, Brock and Scugog. | Jan. 4, 1982 | Feb. 28, 1982 |
T9 | In the Province of Ontario, the Townships of Uxbridge and Scugog in the Regional Municipality of Durham, the Regional Municipality of York (excluding the Townships of East Gwillimbury and Georgina), the Town of Caledon in the Regional Municipality of Peel and the County of Dufferin. | Jan. 3, 1983 | March 31, 1983 |
T10 | In the Province of Ontario, the County of Simcoe, the Townships of East Gwillimbury and Georgina in the Regional Municipality of York and the Township of Brock in the Regional Municipality of Durham. | April 4, 1983 | May 31, 1983 |
H1 | In the Province of Ontario, the Regional Municipality of Hamilton-Wentworth, the City of Burlington, the County of Brant and the Regional Municipality of Haldimand-Norfolk (excluding the Towns of Haldimand and Dunnville). | Jan. 11, 1982 | May 5, 1982 |
H2 | In the Province of Ontario, the Regional Municipality of Niagara and the Towns of Haldimand and Dunnville. | May 10, 1982 | Aug. 31, 1982 |
H3 | In the Province of Ontario, the County of Wellington and the Regional Municipality of Waterloo. | Sept. 6, 1982 | Jan. 31, 1983 |
L1 | In the Province of Ontario, the County of Essex. | Jan. 4, 1982 | April 30, 1982 |
L2 | In the Province of Ontario, the Counties of Kent and Lambton. | May 3, 1982 | July 31, 1982 |
L3 | In the Province of Ontario, the Counties of Middlesex and Elgin. | Aug. 2, 1982 | Feb. 26, 1983 |
L4 | In the Province of Ontario, the Counties of Bruce, Grey and Huron. | June 6, 1983 | Sept. 30, 1983 |
L5 | In the Province of Ontario, the Counties of Perth and Oxford. | Feb. 28, 1983 | June 3, 1983 |
S1 | In the Province of Ontario, the District of Temiskaming. | Jan. 4, 1982 | Feb. 28, 1982 |
S2 | In the Province of Ontario, the District of Cochrane. | March 1, 1982 | May 31, 1982 |
S3 | In the Province of Ontario, the Districts of Parry Sound and Nipissing, excluding the organized and unorganized Townships of Peck, Canisbay, Sproule, Preston, Clancy, Airy, Murchison, Dickens, Sabine and Lyell. | May 31, 1982 | Oct. 31, 1982 |
S4 | In the Province of Ontario, the Districts of Sudbury and Manitoulin and the Regional Municipality of Sudbury. | Nov. 1, 1982 | Feb. 28, 1983 |
S5 | In the Province of Ontario, the District of Algoma. | Feb. 28, 1983 | June 30, 1983 |
TB1 | In the Province of Ontario, the City of Thunder Bay. | Jan. 4, 1982 | Aug. 31, 1982 |
TB2 | In the Province of Ontario, the District of Thunder Bay, excluding the City of Thunder Bay and retail stores along provincial highway 599. | Sept. 6, 1982 | May 31, 1983 |
W1 | In the Province of Manitoba, the City of Winnipeg, the Town of Selkirk, the Village of Dunnottar and the Regional Municipalities of St. Andrews, St. Clements, St. Paul East and St. Paul West. | Jan. 4, 1982 | June 30, 1982 |
W2 | That part of the Province of Manitoba south of the 53rd parallel of latitude and east of the 99th meridian of longitude, excluding area W1. | July 5, 1982 | Sept. 30, 1982 |
W3 | That part of the Province of Manitoba south of the 51st parallel of latitude and west of the 99th meridian of longitude. | Oct. 4, 1982 | Nov. 30, 1982 |
W4 | That part of the Province of Manitoba west of the 99th meridian of longitude between the 51st and 53rd parallels of latitude. | Jan. 3, 1983 | Jan. 31, 1983 |
W5 | That part of the Province of Manitoba north of the 53rd parallel of latitude. | Jan. 31, 1983 | March 31, 1983 |
W6 | In the Province of Ontario, the Districts of Kenora and Rainy River and all retail stores along provincial highway 599. | April 4, 1983 | May 31, 1983 |
SK1 | In the Province of Saskatchewan, Rural Municipalities 8-12, 38-42, 68-72, 98-102, 128-132, 157-163, 187-194 and 217-224, inclusive. | Jan. 4, 1982 | March 31, 1982 |
SK2 | In the Province of Saskatchewan, Rural Municipalities 1-7, 31-37, 61-67, 91-97, 121-127, 151-156, 181-186, 211-216, 241-248, 271-278, 301-308 and 331-338, inclusive. | April 5, 1982 | May 31, 1982 |
SK3 | In the Province of Saskatchewan, Rural Municipalities 17-19, 43-46, 49, 51, 73-79, 103-111, 133-139, 141-142, 164-169, 171 and 229-232, inclusive. | May 31, 1982 | June 30, 1982 |
SK4 | In the Province of Saskatchewan, Rural Municipalities 225, 226, 228, 250-257, 259-261, 279-288, 290, 292, 309, 310, 312-322, 339-347, 349-352, 369-373, 403-405 and 435, inclusive. | July 5, 1982 | Sept. 30, 1982 |
SK5 | That part of Saskatchewan not included in area SK1, SK2, SK3 or SK4, and, in the Province of Alberta, the City of Lloydminster. | Oct. 4, 1982 | Jan. 31, 1983 |
C1 | In the Province of Alberta, the City of Calgary and the Municipal Districts of Foothills and Rocky View. | Jan. 4, 1982 | Sept. 30, 1982 |
C2 | In the Province of Alberta, the City of Red Deer, the Counties of Lacombe, Red Deer and Mountain View and Improvement District 10. | Oct. 4, 1982 | Dec. 31, 1982 |
C3 | In the Province of Alberta, the City of Lethbridge, the Counties of Vulcan, Lethbridge and Warner, the Municipal Districts of Cardston, Pincher Creek, Willow Creek and Taber and Improvement Districts 4, 5 and 6. | Jan. 3, 1983 | March 31, 1983 |
C4 | In the Province of Alberta, Forty Mile County, the City of Medicine Hat and Improvement District 1. | April 4, 1983 | June 30, 1983 |
C5 | In the Province of Alberta, the City of Drumheller, the Counties of Newell, Wheatland, Stettler and Paintearth, the Municipal Districts of Acadia, Starland and Kneehill, Special Areas 2, 3 and 4 and Improvement District 7. | July 4, 1983 | Aug. 31, 1983 |
C6 | In the Province of Alberta, Improvement Districts 8 and 9. | Sept, 5, 1983 | Sept. 30, 1983 |
E1 | In the Province of Alberta, the Cities of Edmonton and St. Albert, the Counties of Strathcona, Leduc and Parkland and the Municipal District of Sturgeon. | Jan. 4, 1982 | July 31, 1982 |
E2 | In the Province of Alberta, the Counties of Ponoka and Wetaskiwin and Improvement Districts 11, 12 and 14. | Aug. 2, 1982 | Sept. 30, 1982 |
E3 | In the Province of Alberta, the Counties of Barrhead and Lac Ste. Anne, the Municipal District of Westlock and Improvement Districts 15 and 17. | Jan. 3, 1983 | March 15, 1983 |
E4 | In the Province of Alberta, the City of Grande Prairie, the County of Grande Prairie, the Municipal Districts of Smoky River, Spirit River, Peace and Fairview and Improvement Districts 16 and 19 to 23, inclusive. | Oct. 4, 1982 | Dec. 31, 1982 |
E5 | In the Province of Alberta, the Counties of Thorhild, Athabaska, Smoky Lake and St. Paul, the Municipal District of Bonnyville and Improvement Districts 18 and 24. | March 14, 1983 | May 15, 1983 |
E6 | In the Province of Alberta, the Counties of Beaver, Two Hills, Camrose, Vermilion River, Minburn, Flagstaff and Lamont, the Municipal Districts of Provost and Wainwright and Improvement District 13, excluding the City of Lloydminster. | May 16, 1983 | July 31, 1983 |
BC1 | In the Province of British Columbia, the City of Kamloops, the Municipality of North Kamloops and the Communities of Tranquille, Brocklehurst, Westsyde and Valleyview. | Jan. 4, 1982 | March 5, 1982 |
BC2 | In the Province of British Columbia, the area defined as Provincial School Districts 12 to 17, 21 to 24, 31, 77 and 89, inclusive, excluding area BC1. | Jan. 4, 1982 | March 5, 1982 |
BC3 | In the Province of British Columbia, the area defined as Provincial School Districts 61 to 66, 68 to 72, 84 and 85, inclusive. | Jan. 4, 1982 | April 30, 1982 |
BC4 | In the Province of British Columbia, the area defined as Provincial School Districts 35 to 48, inclusive. | May 3, 1982 | Feb. 28, 1983 |
BC5 | In the Province of British Columbia, the area defined as Provincial School Districts 29, 30, 32 to 34, 75 and 76, inclusive. | March 1, 1982 | April 30, 1982 |
BC6 | In the Province of British Columbia, the area defined as Provincial School Districts 27, 28 and 54 to 57, inclusive. | May 3, 1982 | Aug. 31, 1982 |
BC7 | In the Province of British Columbia, the area defined as Provincial School Districts 49, 50, 52, 80, 88 and 92. | Sept. 6, 1982 | Dec. 31, 1982 |
BC8 | In the Province of British Columbia, the area defined as Provincial School Districts 1 to 4, 7, 9 to 11, 18, 19, 26 and 86, inclusive. | Jan. 10, 1983 | June 30, 1983 |
A0 | All areas of Canada not included in any other item of this table. | — | Dec. 31, 1983 |
- SOR/81-495, s. 3
DIVISION 3Retailing of Home Furnishings
342 In this Division,
- floor covering
floor covering means any floor covering or constituent part thereof for a home, whether partial or wall-to-wall, and includes resilient floor coverings, tiles, carpets, rugs, undercushions and underpaddings; (couvre-plancher)
- household textile
household textile means any product for use in a home made in whole or in part from a textile fibre, yarn or fabric, except draperies and curtains and their liners, and includes
(a) such products for use on beds or tables,
(b) furniture,
(c) covers for furniture, appliances or bathroom fixtures, including throws and slip-covers, and
(d) towels, dishcloths and bath mats; (textile de maison)
- narrow fabric
narrow fabric has the meaning set out in section 2 of the Textile Labelling and Advertising Regulations; (article de rubanerie)
- piece good
piece good means a fabric sold by unit of measurement, and includes a narrow fabric; (tissu à la pièce)
- textile fibre
textile fibre has the meaning set out in section 2 of the Textile Labelling Act. (fibre textile)
- SOR/79-841, s. 1
343 After December 31, 1979, units of measurement set out in Schedule II to the Act shall not be used in the retail trade of piece goods.
- SOR/79-841, s. 1
344 (1) Subject to subsection (2) and section 345, after December 31, 1979, units of measurement set out in Schedule II to the Act shall not be used in the retail trade of floor coverings, household textiles or wallpaper.
(2) Subject to section 345, after December 31, 1979, units of measurement set out in Schedule II to the Act may be used in the retail trade of floor coverings, household textiles or wallpaper if the equivalent metric units of measurement are shown in a manner at least as prominent as the units of measurement set out in Schedule II to the Act.
- SOR/79-841, s. 1
345 (1) During 1980, section 344 does not apply to
(a) a catalogue;
(b) the label of a commodity that prior to January 1, 1980 is in transit, in a warehouse or received by the retailer; or
(c) advertising outside of retail premises.
(2) After December 31, 1980, subsection 344(2) does not apply to any advertising of floor coverings, household textiles or wallpaper.
- SOR/79-841, s. 1
SCHEDULE I(Section 47.1)
Statement of Quantity
Column I | Column II | |
---|---|---|
Item | Commodity | Parameter |
1 | Baler twine | Mass, length |
- SOR/2005-297, s. 22
SCHEDULE II(Sections 45 and 49)
Limits of Error for Quantities Stated in Metric Units of Mass for Individually Measured Commodities
Column I | Column II | ||
---|---|---|---|
Item | Stated Quantity | Limits of Error | |
% | grams | ||
grams | |||
1 | more than 0 to not more than 60 | 10 | — |
2 | more than 60 to not more than 600 | — | 6 |
3 | more than 600 to not more than 1 000 | 1 | — |
kilograms | |||
4 | more than 1 to not more than 1.5 | — | 10 |
5 | more than 1.5 to not more than 3 | 0.66 | — |
6 | more than 3 to not more than 4 | — | 20 |
7 | more than 4 to not more than 10 | 0.5 | — |
8 | more than 10 to not more than 15 | — | 50 |
9 | more than 15 to not more than 250 | 0.33 | — |
10 | more than 250 to not more than 500 | — | 750 |
11 | more than 500 | 0.15 | — |
Limits of Error for Quantities Stated in Canadian Units of Mass or Weight for Individually Measured Commodities
Column I | Column II | ||
---|---|---|---|
Item | Stated Quantity | Limits of Error | |
% | ounces | ||
ounces | |||
1 | more than 0 to not more than 2 | 10 | — |
2 | more than 2 to not more than 20 | — | 0.2 |
pounds | |||
3 | more than 1.25 to not more than 2.2 | 1 | — |
4 | more than 2.2 to not more than 3.3 | — | 0.35 |
5 | more than 3.3 to not more than 6.6 | 0.66 | — |
6 | more than 6.6 to not more than 8.8 | — | 0.71 |
7 | more than 8.8 to not more than 22 | 0.5 | — |
8 | more than 22 to not more than 33 | — | 1.76 |
9 | more than 33 to not more than 550 | 0.33 | — |
10 | more than 550 to not more than 1,100 | — | 26.4 |
11 | more than 1,100 | 0.15 | — |
Limits of Error for Quantities Stated in Metric Units of Volume for Individually Measured Commodities Not Described in Part VIII
Column I | Column II | ||
---|---|---|---|
Item | Stated Quantity | Limits of Error | |
% | millilitres | ||
litres | |||
1 | more than 0 to not more than 0.05 | 9 | — |
2 | more than 0.05 to not more than 0.1 | — | 4.5 |
3 | more than 0.1 to not more than 0.2 | 4.5 | — |
4 | more than 0.2 to not more than 0.3 | — | 9 |
5 | more than 0.3 to not more than 0.5 | 3 | — |
6 | more than 0.5 to not more than 1 | — | 15 |
7 | more than 1 to not more than 10 | 1.5 | — |
8 | more than 10 to not more than 15 | — | 150 |
9 | more than 15 to not more than 50 | 1 | — |
10 | more than 50 to not more than 100 | — | 500 |
11 | more than 100 | 0.5 | — |
Limits of Error for Quantities Stated in Canadian Units of Volume for Individually Measured Commodities Not Described in Part IX
Column I | Column II | ||
---|---|---|---|
Item | Stated Quantity | Limits of Error | |
% | fluid ounces | ||
fluid ounces | |||
1 | more than 0 to not more than 1.75 | 9 | — |
2 | more than 1.75 to not more than 3.5 | — | 0.15 |
3 | more than 3.5 to not more than 7 | 4.5 | — |
4 | more than 7 to not more than 10.5 | — | 0.3 |
5 | more than 10.5 to not more than 17.5 | 3 | — |
6 | more than 17.5 to not more than 35.2 | — | 0.5 |
gallons | |||
7 | more than 0.22 to not more than 2.2 | 1.5 | — |
8 | more than 2.2 to not more than 3.3 | — | 5.3 |
9 | more than 3.3 to not more than 11 | 1 | — |
10 | more than 11 to not more than 22 | — | 17.6 |
11 | more than 22 | 0.5 | — |
Limits of Error for Quantities Stated in Metric Units of Mass or Volume for Standard Quantity Commodities not Described in Part VIII
Column I | Column II | ||
---|---|---|---|
Item | Stated Quantity | Limits of Error | |
% | grams or millilitres | ||
grams or millilitres | |||
1 | more than 0 to not more than 50 | 9 | — |
2 | more than 50 to not more than 100 | — | 4.5 |
3 | more than 100 to not more than 200 | 4.5 | — |
4 | more than 200 to not more than 300 | — | 9 |
5 | more than 300 to not more than 500 | 3 | — |
6 | more than 500 to not more than 1 000 | — | 15 |
7 | more than 1 000 to not more than 10 000 | 1.5 | — |
8 | more than 10 000 to not more than 15 000 | — | 150 |
9 | more than 15 000 | 1 | — |
Limits of Error for Quantities Stated in Canadian Units of Mass or Weight for Standard Quantity Commodities
Column I | Column II | ||
---|---|---|---|
Item | Stated Quantity | Limits of Error | |
% | ounces | ||
ounces | |||
1 | more than 0 to not more than 1.75 | 9 | — |
2 | more than 1.75 to not more than 3.5 | — | 0.16 |
3 | more than 3.5 to not more than 7 | 4.5 | — |
4 | more than 7 to not more than 10.6 | — | 0.32 |
5 | more than 10.6 to not more than 17.6 | 3 | — |
pounds | |||
6 | more than 1.1 to not more than 2.2 | — | 0.53 |
7 | more than 2.2 to not more than 22 | 1.5 | — |
8 | more than 22 to not more than 33 | — | 5.28 |
9 | more than 33 | 1 | — |
Limits of Error for Quantities Stated in Canadian Units of Volume for Standard Quantity Commodities Not Described in Part IX
Column I | Column II | ||
---|---|---|---|
Item | Stated Quantity | Limits of Error | |
% | fluid ounces | ||
fluid ounces | |||
1 | more than 0 to not more than 1.75 | 9 | — |
2 | more than 1.75 to not more than 3.5 | — | 0.16 |
3 | more than 3.5 to not more than 7 | 4.5 | — |
4 | more than 7 to not more than 10.6 | — | 0.32 |
5 | more than 10.6 to not more than 17.6 | 3 | — |
6 | more than 17.6 to not more than 35.2 | — | 0.53 |
gallons | |||
7 | more than 0.22 to not more than 2.2 | 1.5 | — |
8 | more than 2.2 to not more than 3.3 | — | 5.28 |
9 | more than 3.3 | 1 | — |
Limits of Error for Quantities of Solid Commodities Stated in Metric Units of Volume
Column I | Column II | |
---|---|---|
Item | Stated Quantity | Limits of Error |
cubic metres | ||
1 | less than 1 | 3% of stated quantity |
2 | from 1 to 2 | 0.03 cubic metres |
3 | more than 2 | 1.5% of stated quantity |
Limits of Error for Quantities of Solid Commodities Stated in Canadian Units of Volume
Column I | Column II | |
---|---|---|
Item | Stated Quantity | Limits of Error |
cubic yards | ||
1 | less than 1 | 3% of stated quantity |
2 | from 1 to 2 | 0.03 cubic yards |
3 | more than 2 | 1.5% of stated quantity |
Limits of Error for Quantities Stated in Metric Units of Length
Column I | Column II | |
---|---|---|
Item | Stated Quantity | Limits of Error |
For thread and yarn: | ||
1 | any length | 4% of stated quantity |
For baler twine: | ||
2 | any length | 5% of stated quantity |
For rolls of fabric: | ||
3 | individual rolls | 2% of stated quantity |
4 | entire lots based on a minimum sample of 10% | 1% of stated quantity |
For other commodities: | ||
5 | less than 3 m | 2% of stated quantity |
6 | 3 to 6 m | 60 mm |
7 | more than 6 m | 1% of stated quantity |
Limits of Error for Quantities Stated in Canadian Units of Length
Column I | Column II | |
---|---|---|
Item | Stated Quantity | Limits of Error |
For thread and yarn: | ||
1 | any length | 4% of stated quantity |
For baler twine: | ||
2 | any length | 5% of stated quantity |
For rolls of fabric: | ||
3 | individual rolls | 2% of stated quantity |
4 | entire lots based on a minimum sample of 10% | 1% of stated quantity |
For other commodities: | ||
5 | less than 10 feet | 2% of stated quantity |
6 | 10 to 20 feet | 2.4 inches |
7 | more than 20 feet | 1% of stated quantity |
Limits of Error for Quantities Stated in Metric Units of Area
Column I | Column II | |
---|---|---|
Item | Stated Quantity | Limits of Error |
square metres | ||
1 | less than 10 | 2% of stated quantity |
2 | from 10 to 20 | 0.2 square metres |
3 | more than 20 | 1% of stated quantity |
Limits of Error for Quantities Stated in Canadian Units of Area
Column I | Column II | |
---|---|---|
Item | Stated Quantity | Limits of Error |
square feet | ||
1 | less than 100 | 2% of stated quantity |
2 | from 100 to 200 | 2 square feet |
3 | more than 200 | 1% of stated quantity |
Limits of Error for Quantities Stated by Number
Column I | Column II | |
---|---|---|
Item | Stated Quantity | Limits of Error |
number of articles | ||
1 | less than 50 | 0 article |
2 | from 50 to 100 | 1 article |
3 | more than 100 with an individual weight of 14 grams or less, or ½ ounce or less | 0.75% of the stated quantity, rounded up to the next whole number |
4 | more than 100 with an individual weight of more than 14 grams, or more than ½ ounce | 0.5% of the stated quantity, rounded up to the next whole number |
Limits of Error for Precious Metals and other Commodities of Comparable Value the Quantity of Which Is Stated in Metric Units of Mass
Column I | Column II | |
---|---|---|
Item | Stated Quantity | Limits of Error |
grams | milligrams | |
1 | up to and including 30 | 12.5 |
2 | 50 | 17 |
3 | 100 | 30 |
4 | 200 | 56 |
5 | 300 | 81 |
6 | 500 | 131 |
7 | 1 000 | 240 |
8 | 1 500 | 350 |
9 | 2 000 | 425 |
10 | 3 000 | 575 |
11 | 5 000 | 900 |
12 | 6 000 | 1 050 |
13 | more than 6 000 | 0.0175% of the stated quantity |
Where a quantity is not listed in column I of this Part, the limits of error for that quantity shall be determined by linear interpolation.
Limits of Error for Precious Metals and other Commodities of Comparable Value the Quantity of Which Is Stated in Canadian Units of Mass or Weight
Column I | Column II | |
---|---|---|
Item | Stated Quantity | Limits of Error |
troy ounces | grains | |
1 | up to and including 1 | 0.2 |
2 | 2 | 0.3 |
3 | 5 | 0.7 |
4 | 10 | 1.3 |
5 | 20 | 2.5 |
6 | 50 | 5.6 |
7 | 100 | 9.4 |
8 | 200 | 16.8 |
9 | more than 200 | 0.0175% of the stated quantity |
Where a quantity is not listed in column I of this Part, the limits of error for that quantity shall be determined by linear interpolation.
- SOR/80-429, s. 3
- SOR/89-570, ss. 4, 6(F)
- SOR/2005-297, ss. 23 to 37
SCHEDULE III(Section 52)
PART ISamples
Column I | Column II | |
---|---|---|
Item | Number of Units in the Lot | Minimum Number of Units in the Sample |
1 | from 2 to 10 | All the units in the lot |
2 | from 11 to 128 | 25% of the units in the lot, rounded up to the next whole number, but not less than 10 |
3 | from 129 to 4 000 | 32 |
4 | from 4 001 to 8 000 | 64 |
5 | from 8 001 to 12 000 | 96 |
6 | more than 12 000 | 125 |
PART IIFormula for Determining the Weighted Average Quantity of the Units in a Sample
For the purposes of paragraph 52(4)(a), the formula for adjusting the sample mean to determine the weighted average quantity of the units in the sample is as follows:
where
- a
- is the weighted average quantity of the units in the sample
- is the sample mean calculated as follows:
= Σx ÷ n
- Σx
- is the sum of the net quantities of all units in the sample
- t
- is the value determined in accordance with Part III for the selected sample size
- n
- is the number of units in the sample
- s
- is the standard deviation of the sample, calculated as follows:
- Σ(x- )2
- is the sum of the squared differences between the sample mean and the net quantity of each unit in the sample.
Return to footnote *The value of (t ÷ √n) may, instead of being calculated in accordance with this Part, be determined using the applicable value set out in column III of the table to Part III.
PART IIITable for Values of t and (t ÷ √n)
Column I | Column II | Column III | |
---|---|---|---|
Sample Size | tFootnote for * | (t ÷ √n)Footnote for * | |
2 | 63.657 | 45.01 | Linear Interpolation of Values |
3 | 9.925 | 5.73 | Where a sample size is selected that is not listed in column I of this table and lies between 32 and 125, the value of t will be determined by linear interpolation as follows: t = a - (c-e) ÷ (c-d)(a-b) where
|
4 | 5.841 | 2.92 | |
5 | 4.604 | 2.06 | |
6 | 4.032 | 1.65 | |
7 | 3.707 | 1.40 | |
8 | 3.499 | 1.24 | |
9 | 3.355 | 1.12 | |
10 | 3.250 | 1.03 | |
11 | 3.169 | 0.955 | |
12 | 3.106 | 0.897 | |
13 | 3.055 | 0.847 | |
14 | 3.012 | 0.805 | |
15 | 2.977 | 0.769 | |
16 | 2.947 | 0.737 | |
17 | 2.921 | 0.708 | |
18 | 2.898 | 0.683 | |
19 | 2.878 | 0.660 | |
20 | 2.861 | 0.640 | |
21 | 2.845 | 0.621 | |
22 | 2.831 | 0.604 | |
23 | 2.819 | 0.588 | |
24 | 2.807 | 0.573 | |
25 | 2.797 | 0.559 | |
26 | 2.787 | 0.547 | |
27 | 2.779 | 0.535 | |
28 | 2.771 | 0.524 | |
29 | 2.763 | 0.513 | |
30 | 2.756 | 0.503 | |
31 | 2.750 | 0.494 | |
32 | 2.746 | 0.485 | |
64 | 2.657 | 0.332 | |
96 | 2.634 | 0.269 | |
125 | 2.615 | 0.234 |
Return to footnote *Where all units in a lot are selected to constitute a sample, zero shall be used as the value of t and (t ÷ √n).
PART IVMinimum Number of Units for the Purposes of Paragraph 52(4)(B)
Column I | Column II | |
---|---|---|
Item | Sample Size | Minimum Number of UnitsFootnote for * |
1 | from 2 to 8 | 1 |
2 | from 9 to 20 | 2 |
3 | from 21 to 32 | 3 |
4 | from 33 to 50 | 4 |
5 | from 51 to 65 | 5 |
6 | from 66 to 80 | 6 |
7 | from 81 to 102 | 7 |
8 | from 103 to 125 | 8 |
Return to footnote *Minimum number of units in the sample that result in the lot not meeting the requirements of the Act and these Regulations respecting the statement of quantity.
- SOR/89-570, s. 5
SCHEDULE IV(ss. 53 and 54)Tolerances for Local Standards
Tolerances for Local Standards of Mass that Have a Nominal Value Shown in Metric Units and that Are Used to Inspect Devices for Weighing Precious Metals
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
Grams | ||
1 | More than 100 | 0.0015% of Nominal Value |
Milligrams | ||
2 | 100 | 1.5 |
3 | 50 | 1 |
4 | 20 | 0.8 |
5 | 10 | 0.6 |
6 | 5 | 0.5 |
7 | 2 | 0.4 |
8 | 1 | 0.3 |
Milligrams | ||
9 | 500 | 0.25 |
10 | 200 | 0.2 |
11 | 100 | 0.15 |
12 | 50 | 0.12 |
13 | 20 | 0.1 |
14 | 10 | 0.08 |
15 | 5 or less | 0.06 |
Tolerances for Local Standards of Mass or Weight that Have a Nominal Value Shown in Canadian Units and that Are Used to Inspect Devices for Weighing Precious Metals
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
Troy Ounces | ||
1 | More than 5 | 0.0015% of Nominal Value |
Grains | ||
2 | 5 | 0.036 |
3 | 2 | 0.0173 |
4 | 1 | 0.0135 |
5 | 0.5 | 0.011 |
6 | 0.2 | 0.0081 |
7 | 0.1 | 0.0067 |
8 | 0.05 | 0.0055 |
9 | 0.02 | 0.0041 |
10 | 0.01 | 0.0034 |
11 | 0.005 | 0.0027 |
12 | 0.002 | 0.002 |
13 | 0.001 | 0.0017 |
Grains | ||
14 | 1,000 | 0.0177 |
15 | 600 | 0.0143 |
16 | 300 | 0.0122 |
17 | 200 | 0.0102 |
18 | 100 | 0.0082 |
19 | 60 | 0.0071 |
20 | 30 | 0.0061 |
21 | 20 | 0.0051 |
22 | 10 | 0.0041 |
23 | 6 | 0.0036 |
24 | 3 | 0.003 |
25 | 2 | 0.0025 |
26 | 1 | 0.002 |
27 | 0.6 | 0.0017 |
28 | 0.3 | 0.0015 |
29 | 0.2 | 0.001 |
30 | 0.1 or less | 0.0009 |
Tolerances for Local Standards of Mass that Have a Nominal Value Shown in Metric Units and that Are Used to Inspect Devices for Weighing Commodities other than Precious Metals
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
Kilograms | ||
1 | More than 1 | 0.005% of Nominal Value |
Milligrams | ||
2 | 1 | 50 |
Grams | ||
3 | 500 | 25 |
4 | 200 | 10 |
5 | 100 | 5 |
6 | 50 | 3 |
7 | 20 | 2.5 |
8 | 10 | 2 |
9 | 5 | 1.5 |
10 | 2 | 1.2 |
11 | 1 | 1 |
Milligrams | ||
12 | 500 | 0.8 |
13 | 200 | 0.6 |
14 | 100 | 0.5 |
15 | 50 | 0.4 |
16 | 20 | 0.3 |
17 | 10 | 0.25 |
18 | 5 or less | 0.2 |
Tolerances for Local Standards of Mass or Weight that Have a Nominal Value Shown in Canadian Units and that Are Used to Inspect Devices for Weighing Commodities other than Precious Metals
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
Pounds | ||
1 | More than 1 | 0.005% of Nominal Value |
Grains | ||
2 | 1 | 0.35 |
3 | 0.5 | 0.175 |
4 | 0.2 | 0.071 |
5 | 0.1 | 0.045 |
6 | 0.05 | 0.035 |
7 | 0.02 | 0.028 |
8 | 0.01 | 0.022 |
9 | 0.005 | 0.018 |
10 | 0.002 | 0.015 |
11 | 0.001 | 0.012 |
Ounces | ||
12 | 8 | 0.175 |
13 | 4 | 0.088 |
14 | 2 | 0.05 |
15 | 1 | 0.041 |
16 | ½ | 0.034 |
17 | ¼ | 0.026 |
18 | 1/8 | 0.021 |
19 | 1/16 | 0.018 |
20 | 1/32 | 0.015 |
Grains | ||
21 | 1,000 | 0.055 |
22 | 600 | 0.043 |
23 | 300 | 0.038 |
24 | 200 | 0.033 |
25 | 100 | 0.025 |
26 | 60 | 0.021 |
27 | 30 | 0.018 |
28 | 20 | 0.016 |
29 | 10 | 0.013 |
30 | 6 | 0.011 |
31 | 3 | 0.009 |
32 | 2 | 0.008 |
33 | 1 | 0.007 |
34 | 0.6 | 0.006 |
35 | 0.3 | 0.005 |
36 | 0.2 | 0.004 |
37 | 0.1 or less | 0.003 |
Tolerances for All Local Standards of Length that Have a Nominal Value Shown in Metric Units
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
Metres | Millimetres | |
1 | 30 | 4 |
2 | 15 | 3 |
3 | 3 | 1.5 |
4 | 2 | 1.0 |
5 | 1 | 0.5 |
Millimetres | ||
6 | 500 | 0.4 |
7 | 300 | 0.3 |
8 | 100 | 0.1 |
9 | 25 | 0.05 |
Tolerances for All Local Standards of Length that Have a Nominal Value Shown in Canadian Units
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
Feet | Inches | |
1 | 100 | 0.15 |
2 | 50 | 0.10 |
3 | 10 | 0.05 |
4 | 6 | 0.04 |
5 | 3 | 0.025 |
6 | 2 | 0.015 |
7 | 1 | 0.010 |
Inches | ||
8 | 6 | 0.005 |
9 | 1 | 0.001 |
Tolerances for Narrow Neck Standards that Have a Nominal Value Shown in Metric Units
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
Litres | ||
1 | 50 or more | 0.04% of the nominal value |
2 | 20 | 10 mL |
3 | 5 | 6 mL |
4 | 2 | 3 mL |
5 | 1 | 1.5 mL |
6 | 0.5 | 0.9 mL |
7 | 0.2 or less | 0.25% of the nominal value |
Tolerances for Narrow Neck Standards that Have a Nominal Value Shown in Canadian Units
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
Gallons | ||
1 | 10 or more | 0.04% of the nominal value |
2 | 5 | 0.40 fluid ounces |
3 | 1 | 0.18 fluid ounces |
Quarts | ||
4 | 3 | 0.15 fluid ounces |
5 | 2 | 0.12 fluid ounces |
6 | 1 | 0.06 fluid ounces |
Pints | ||
7 | 1 | 0.05 fluid ounces |
8 | 0.5 or less | 0.25% of the nominal value |
Tolerance for Stoppered Pycnometer Standards
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
1 | Any volume | 0.02% of the volume |
PART X[Revoked, SOR/93-234, s. 2]
Tolerances for Cylindrical Graduated Standards of Volume that Have a Nominal Value Shown in Metric Units
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
Millilitres | Millilitres | |
1 | 2 000 | 8.0 |
2 | 1 000 | 5.0 |
3 | 500 | 3.0 |
4 | 250 | 1.6 |
5 | 200 | 1.4 |
6 | 100 | 0.8 |
7 | 50 | 0.5 |
8 | 25 | 0.3 |
9 | 10 | 0.16 |
10 | 5 | 0.12 |
Tolerances for Cylindrical Graduated Standards of Volume that Have a Nominal Value Shown in Canadian Units
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
Fluid Ounces | Fluid Ounces | |
1 | 40 | 0.20 |
2 | 5 | 0.04 |
3 | 4 | 0.04 |
Tolerance for Master Meter Standards that Are Used to Inspect Liquefied Gas Measuring Machines
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
1 | A volume corresponding to a delivery lasting at least one minute | Not more than 0.05% difference in the registered volume for any number of tests made under the same controlled conditions |
Tolerance for Master Meter Standards that Are Used to Inspect Meters other than Liquefied Gas Measuring Machines
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
1 | A volume corresponding to a delivery lasting at least one minute | No more than 0.03% difference in the registered volume for any number of tests made under the same controlled conditions |
Tolerance for Pipe Prover Standards with Entirely Mechanical Means of Registration
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
1 | Any base volume | 0.05% of the volume |
Tolerance for Pipe Prover Standards with a Means of Registration other than Entirely Mechanical
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
1 | Any base volume | 0.02% of the volume |
Tolerance for Gravimetric Prover Standards
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
1 | Any mass or weight | 20 g or the value of the minimum increment of registration, whichever is the lesser |
Tolerance for Hydrometer Standards
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
1 | Any density or relative density | 0.2% of the density or relative density |
Tolerances for Standards of Temperature
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
1 | Any temperature from -40°C to +50°C | 0.25°C |
2 | Any temperature greater than +50°C to +175°C | 0.6°C |
Tolerances for Electricity Measuring Standards
Column I | Column II | |
---|---|---|
Item | Nominal Value of Local Standard | Tolerance |
1 | Any indication in watt hours | 0.05% of the nominal value |
2 | Any indication in volt ampere hours | 0.1% of the nominal value |
3 | Any indication in var hours | 0.1% of the nominal value |
4 | Any indication in amperes rms | 0.1% of the nominal value |
5 | Any indication in volts rms | 0.1% of the nominal value |
- SOR/89-570, s. 6(F)
- SOR/90-118, ss. 43, 44
- SOR/93-234, s. 2
- SOR/2005-297, ss. 38, 39
SCHEDULE V(Section 59)Fees and Charges
Inspector’s Services
Column I | Column II | |
---|---|---|
Item | Inspector’s Services and Related Expenses | Fees and Charges |
1 | For a service referred to in subsection 59(1) of these Regulations provided by an inspector, for each half hour or part thereof, as follows: | |
(a) during the inspector’s regular working hours | $30.00 | |
(b) outside the inspector’s regular working hours | $45.00 | |
2 | Expenses incurred by the inspector in relation to the provision of a service referred to in subsection 59(1) of these Regulations for accommodation, meals and incidental expenses and for transportation to and from the place where the service is provided | the rates and allowances set out in the “Travel Directive” contained in the Treasury Board Manual |
Equipment and Vehicles
Column I | Column II | |
---|---|---|
Item | Provision of Equipment and Vehicles | Charges |
1 | For the provision by an inspector, in order to provide a service referred to in subsection 59(1) of these Regulations, of a piece of equipment or a vehicle set out in any of subitems (a) to (h), for each hour or part thereof, with the exception of subitem (f), as follows: | |
(a) volumetric prover standard, unless set out in subitems (c), (d) and (e), of | ||
| $20.00 | |
| $80.00 | |
(b) narrow neck sanitary prover standard or narrow neck liquefied gas prover standard of the vapour displacement type | $30.00 | |
(c) gravimetric prover standard designed to inspect meters that measure liquefied gases | $40.00 | |
(d) pipe prover standard designed to inspect meters with a marked maximum flow rate of | ||
| $30.00 | |
| $100.00 | |
(e) master meter standard designed to inspect meters with a marked maximum flow rate of | ||
| $30.00 | |
| $100.00 | |
(f) one or more standards that have a total mass of 500 kg or more, per tonne or part thereof, for each 24 hour period or part thereof | $15.00 | |
(g) portable weighing equipment with a capacity greater than 1 000 kg, including equipment designed to inspect on-board weighing systems that measure anhydrous ammonia | $50.00 | |
(h) motor vehicle and the standards carried on that vehicle where the standards have a total mass of | ||
| $60.00 | |
| $95.00 | |
2 | For the transportation by an inspector, in order to provide a service referred to in subsection 59(1) of these Regulations, of a piece of equipment or a vehicle set out in item 1 to and from the place where the service is provided | the rates and allowances set out for an employee in the “Travel Directive” contained in the Treasury Board Manual |
- SOR/79-747, s. 2
- SOR/85-736, s. 3
- SOR/87-582, s. 5
- SOR/93-413, s. 3
- Date modified: