<?xml version="1.0"?><Regulation lims:pit-date="2024-10-23" hasPreviousVersion="true" lims:lastAmendedDate="2024-10-23" lims:current-date="2024-10-30" lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489319" lims:id="1489319" gazette-part="II" regulation-type="SI" xml:lang="en" xmlns:lims="http://justice.gc.ca/lims"><Identification lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489320" lims:id="1489320"><InstrumentNumber>SI/2024-48</InstrumentNumber><RegistrationDate><Date><YYYY>2024</YYYY><MM>10</MM><DD>23</DD></Date></RegistrationDate><ConsolidationDate><Date><YYYY>2024</YYYY><MM>10</MM><DD>31</DD></Date></ConsolidationDate><EnablingAuthority lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489321" lims:id="1489321"><XRefExternal reference-type="act" link="W-6">WEIGHTS AND MEASURES ACT</XRefExternal></EnablingAuthority><LongTitle lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489322" lims:id="1489322">Specifications Relating to Timber Dimension Measuring Devices</LongTitle></Identification><Order lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489323" lims:id="1489323"><Provision lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489324" lims:id="1489324" format-ref="indent-0-0" language-align="yes" list-item="no"><Text>The Minister of Industry establishes the annexed <XRefExternal reference-type="regulation" link="SI-2024-48">Specifications Relating to Timber Dimension Measuring Devices</XRefExternal> under sections 13<FootnoteRef idref="fn_81000-2-4362_hq_1675346980">a</FootnoteRef> and 27<FootnoteRef idref="fn_81000-2-4362_hq_1675347012">b</FootnoteRef> of the <XRefExternal reference-type="regulation" link="C.R.C.,_c._1605">Weights and Measures Regulations</XRefExternal><FootnoteRef idref="fn_81000-2-4362_hq_1675347038">c</FootnoteRef>.</Text><Footnote id="fn_81000-2-4362_hq_1675346980" placement="page" status="official"><Label>a</Label><Text>SOR/2005-297, s. 3</Text></Footnote><Footnote id="fn_81000-2-4362_hq_1675347012" placement="page" status="official"><Label>b</Label><Text>SOR/93-234</Text></Footnote><Footnote id="fn_81000-2-4362_hq_1675347038" placement="page" status="official"><Label>c</Label><Text>C.R.C., c. 1605; SOR/2017-198, s. 1</Text></Footnote></Provision><Provision lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489325" lims:id="1489325" format-ref="indent-0-0" language-align="yes" list-item="no" topmarginspacing="12"><Text>Ottawa, March 19, 2024</Text><TableGroup lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489326" lims:id="1489326" bilingual="yes" orientation="portrait" pointsize="11pt" topmarginspacing="50pt"><table lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489327" lims:id="1489327" frame="none"><tgroup lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489328" lims:id="1489328" cols="2"><colspec colname="1" colwidth="100*" /><colspec colname="COLSPEC0" colwidth="100.00*" /><tbody lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489329" lims:id="1489329"><row rowsep="0"><entry colsep="0" nameend="COLSPEC0" namest="1" rowsep="0" valign="top"><SignatureBlock justification="center" width="20pc"><SignatureTitle justification="center"><Language xml:lang="fr">Le ministre de l’Industrie,</Language></SignatureTitle><SignatureLine justification="center" topmarginspacing="30"><Leader leader="solid" length="20pc" /></SignatureLine><SignatureName justification="center">François-Philippe Champagne</SignatureName><SignatureTitle justification="center">Minister of Industry</SignatureTitle></SignatureBlock></entry></row></tbody></tgroup></table></TableGroup></Provision></Order><Body lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489330" lims:id="1489330"><Heading lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489331" lims:id="1489331" level="1"><TitleText>Definitions</TitleText></Heading><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489332" lims:id="1489332"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489333" lims:id="1489333">Definitions</MarginalNote><Label>1</Label><Text>The following definitions apply in these Specifications.</Text><Definition lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489334" lims:id="1489334"><Text><DefinedTermEn>auxiliary equipment</DefinedTermEn> means equipment that is connected to, or used in conjunction with, a timber dimension measuring device. (<DefinedTermFr>matériel auxiliaire</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489335" lims:id="1489335"><Text><DefinedTermEn>default temperature range</DefinedTermEn> means, in respect of a timber dimension measuring device, a temperature range of -10°C to +40°C. (<DefinedTermFr>plage de températures par défaut</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489336" lims:id="1489336"><Text><DefinedTermEn>diameter</DefinedTermEn> means, in respect of a log, its theoretical diameter, in centimetres or metres, calculated by measuring its actual circumference and dividing that value by pi (π). (<DefinedTermFr>diamètre</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489337" lims:id="1489337"><Text><DefinedTermEn>disturbance</DefinedTermEn> means a phenomenon or event — such as a short time power reduction or an electrostatic discharge, electrical burst or electromagnetic or electrostatic field — to which a timber dimension measuring device may be exposed and the characteristics of which are inconsistent with the operating parameters of the device. (<DefinedTermFr>perturbation</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489338" lims:id="1489338"><Text><DefinedTermEn>indicator</DefinedTermEn> means a digital device that is an integral part of, or is connected to, a measuring element and that displays measurement registrations. (<DefinedTermFr>indicateur</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489339" lims:id="1489339"><Text><DefinedTermEn>influence factor</DefinedTermEn> means a phenomenon or event to which a timber dimension measuring device or any of its auxiliary equipment may be exposed and that may affect the performance of the device. (<DefinedTermFr>facteur d’influence</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489340" lims:id="1489340"><Text><DefinedTermEn>interval</DefinedTermEn> or <DefinedTermEn>d</DefinedTermEn> means the value, expressed in units of length, of the difference between two consecutively indicated values for any axis of measurement of a timber dimension measuring device. (<DefinedTermFr>échelon</DefinedTermFr> ou <DefinedTermFr>d</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489341" lims:id="1489341"><Text><DefinedTermEn>length</DefinedTermEn> means, in respect of a log, the maximum distance of a straight line, in centimetres or metres, that</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489342" lims:id="1489342"><Label>(a)</Label><Text>is measured as closely as possible along the longitudinal axis of the log; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489343" lims:id="1489343"><Label>(b)</Label><Text>is between two planes that are perpendicular to that axis and located at each end of the log. (<DefinedTermFr>longueur</DefinedTermFr>)</Text></Paragraph></Definition><Definition lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489344" lims:id="1489344"><Text><DefinedTermEn>measurement registration</DefinedTermEn> means a displayed, printed or recorded representation of the measurement information for a log that has been measured by a timber dimension measuring device, including the dimension measured, the measurement value and the unit of measurement. (<DefinedTermFr>enregistrement d’une mesure</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489345" lims:id="1489345"><Text><DefinedTermEn>measuring element</DefinedTermEn> means the parts of a timber dimension measuring device, other than the indicator, that together produce the measurement of a log. (<DefinedTermFr>élément mesureur</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489346" lims:id="1489346"><Text><DefinedTermEn>metrological function</DefinedTermEn> means a function of a timber dimension measuring device that is necessary for the measurement process and that may affect measurement registrations or the validity of transactions, including the sensing of the measured object, the transmission, processing, storage, correction or adjustment of measurement signals or values and the display or printing of measurement values. (<DefinedTermFr>fonction métrologique</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489347" lims:id="1489347"><Text><DefinedTermEn>ready condition</DefinedTermEn> means, in respect of a timber dimension measuring device, the condition in which it is ready to take a measurement. (<DefinedTermFr>état prêt</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489348" lims:id="1489348"><Text><DefinedTermEn>timber dimension measuring device</DefinedTermEn> means a measuring machine that measures the length and diameter of logs. (<DefinedTermFr>appareil de mesure des dimensions du bois</DefinedTermFr>)</Text></Definition></Section><Heading lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489349" lims:id="1489349" level="1"><TitleText>General</TitleText></Heading><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489350" lims:id="1489350"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489351" lims:id="1489351">Specifications prevail</MarginalNote><Label>2</Label><Text>In the event of a conflict between these Specifications and an instruction issued by the manufacturer or importer, these Specifications prevail to the extent of the conflict.</Text></Section><Heading lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489352" lims:id="1489352" level="1"><TitleText>Performance</TitleText></Heading><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489353" lims:id="1489353"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489354" lims:id="1489354">Limits of error</MarginalNote><Label>3</Label><Text>The acceptance limits of error and the in-service limits of error that apply to a timber dimension measuring device are ±1 d for the axis and measuring range in use.</Text></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489355" lims:id="1489355"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489356" lims:id="1489356">Influence factors</MarginalNote><Label>4</Label><Text>A timber dimension measuring device must perform within the applicable limits of error referred to in section <XRefInternal>3</XRefInternal> when, under controlled conditions, the device is tested while it is exposed to an influence factor, such as:</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489357" lims:id="1489357"><Label>(a)</Label><Text>if the device is powered by alternating current, a voltage that is within the range of -15% to +10% of the nominal voltage of the device;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489358" lims:id="1489358"><Label>(b)</Label><Text>if the device is powered by direct current,</Text><Subparagraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489359" lims:id="1489359"><Label>(i)</Label><Text>a voltage that is less than the nominal voltage of the device and at which voltage the device can produce a measurement registration, and</Text></Subparagraph><Subparagraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489360" lims:id="1489360"><Label>(ii)</Label><Text>a voltage that is up to 10% greater than the nominal voltage of the device;</Text></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489361" lims:id="1489361"><Label>(c)</Label><Text>a temperature that is</Text><Subparagraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489362" lims:id="1489362"><Label>(i)</Label><Text>in the case where the temperature range specified for the device by the manufacturer is a range that spans at least 30°C and is entirely within the default temperature range, that specified temperature range, and</Text></Subparagraph><Subparagraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489363" lims:id="1489363"><Label>(ii)</Label><Text>in any other case, the default temperature range;</Text></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489364" lims:id="1489364"><Label>(d)</Label><Text>a humidity level of up to 85% relative humidity and a temperature that is</Text><Subparagraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489365" lims:id="1489365"><Label>(i)</Label><Text>in the case where the temperature range specified for the device by the manufacturer is a range that spans at least 30°C and is entirely within the default temperature range, that specified temperature range, and</Text></Subparagraph><Subparagraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489366" lims:id="1489366"><Label>(ii)</Label><Text>in any other case, the default temperature range;</Text></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489367" lims:id="1489367"><Label>(e)</Label><Text>if the device measures using optical principles, an ambient light level that is within the range of 100 lx to 100 000 lx; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489368" lims:id="1489368"><Label>(f)</Label><Text>if the device measures using acoustic principles, an acoustic interference of up to 100 dB at the nominal centre frequency of the device’s ultrasonic transducers.</Text></Paragraph></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489369" lims:id="1489369"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489370" lims:id="1489370">Eccentric measurements</MarginalNote><Label>5</Label><Text>A timber dimension measuring device must perform within the applicable limits of error referred to in section <XRefInternal>3</XRefInternal> when, under controlled conditions, the device is tested while it measures a log in an off-center position.</Text></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489371" lims:id="1489371"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489372" lims:id="1489372">Disturbances</MarginalNote><Label>6</Label><Text>When a timber dimension measuring device is exposed to a disturbance, it must</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489373" lims:id="1489373"><Label>(a)</Label><Text>provide a measurement registration that is ±1 d from the measurement registration that would be provided without the disturbance;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489374" lims:id="1489374"><Label>(b)</Label><Text>provide a blank measurement registration and prevent the measurement information from being displayed, transmitted, printed or stored;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489375" lims:id="1489375"><Label>(c)</Label><Text>provide an error message and prevent the measurement information from being displayed, transmitted, printed or stored; or</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489376" lims:id="1489376"><Label>(d)</Label><Text>provide a measurement registration that is so unstable that it cannot be interpreted as representing the correct measurement values.</Text></Paragraph></Section><Heading lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489377" lims:id="1489377" level="1"><TitleText>Design, Composition and Construction</TitleText></Heading><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489378" lims:id="1489378"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489379" lims:id="1489379">Accuracy and fraud prevention</MarginalNote><Label>7</Label><Text>A timber dimension measuring device must be designed, composed and constructed in a manner that, under normal conditions of use, enables it to measure accurately and does not facilitate the perpetration of fraud.</Text></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489380" lims:id="1489380"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489381" lims:id="1489381">Examination and testing</MarginalNote><Label>8</Label><Text>A timber dimension measuring device must be designed, composed and constructed in a manner that enables it to be examined and enables physical test standards or test objects to be applied to it and recovered before they are processed by any other device.</Text></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489382" lims:id="1489382"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489383" lims:id="1489383">Intervals</MarginalNote><Label>9</Label><Text>Each interval of a timber dimension measuring device must be</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489384" lims:id="1489384"><Label>(a)</Label><Text>displayed or printed in decimal form, with the decimal submultiple of the unit of length being set apart by a decimal point or comma; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489385" lims:id="1489385"><Label>(b)</Label><Text>equal to 1 × 10<Sup>n</Sup>, 2 × 10<Sup>n</Sup> or 5 × 10<Sup>n</Sup> units of length, where “n” is an integer.</Text></Paragraph></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489386" lims:id="1489386"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489387" lims:id="1489387">Rounding measurement values</MarginalNote><Label>10</Label><Text>If a measurement value for a log falls between successive intervals, the timber dimension measuring device must round the value to the nearest interval or, if the value is equidistant between successive intervals, round it up to the nearest interval.</Text></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489388" lims:id="1489388"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489389" lims:id="1489389">Software identification</MarginalNote><Label>11</Label><Text>A timber dimension measuring device must be equipped with a feature that identifies the name and version of the software that it uses.</Text></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489390" lims:id="1489390"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489391" lims:id="1489391">Indicator</MarginalNote><Label>12</Label><Text>A timber dimension measuring device must be equipped with</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489392" lims:id="1489392"><Label>(a)</Label><Text>an indicator that has digits, letters or symbols that are of a consistent design, number and size and that permit measurement registrations to be clearly displayed; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489393" lims:id="1489393"><Label>(b)</Label><Text>if the indicator displays information provided by the device and any other source, a feature that displays measurement registrations separately from the information provided by the other source.</Text></Paragraph></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489394" lims:id="1489394"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489395" lims:id="1489395">Portable second indicator</MarginalNote><Label>13</Label><Subsection lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489396" lims:id="1489396"><Label>(1)</Label><Text>A timber dimension measuring device must be equipped with a portable second indicator if the device is installed such that, during an examination of the device by an inspector, the indicator required under section <XRefInternal>12</XRefInternal> cannot be readily observed by the inspector when they are at the measuring element.</Text></Subsection><Subsection lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489397" lims:id="1489397"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489398" lims:id="1489398">Requirements</MarginalNote><Label>(2)</Label><Text>The portable second indicator must</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489399" lims:id="1489399"><Label>(a)</Label><Text>be readily connectable to all of the measuring elements without affecting their performance;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489400" lims:id="1489400"><Label>(b)</Label><Text>be configured to display the same information as the indicator required under section <XRefInternal>12</XRefInternal>; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489401" lims:id="1489401"><Label>(c)</Label><Text>display information that is in exact agreement with the information displayed by the indicator required under section <XRefInternal>12</XRefInternal>.</Text></Paragraph></Subsection></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489402" lims:id="1489402"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489403" lims:id="1489403">Error handling</MarginalNote><Label>14</Label><Text>A timber dimension measuring device must be equipped with a mechanism or feature, or be connected to auxiliary equipment that is equipped with a mechanism or feature, that prevents a log from being processed after the device provides an error message or blank measurement registration.</Text></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489404" lims:id="1489404"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489405" lims:id="1489405">Devices with multiple measuring elements</MarginalNote><Label>15</Label><Text>A timber dimension measuring device that is installed such that multiple measuring elements are connected to one indicator or printer must be equipped with</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489406" lims:id="1489406"><Label>(a)</Label><Text>a feature that automatically identifies the measuring element that is in use and is providing information to the indicator or printer; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489407" lims:id="1489407"><Label>(b)</Label><Text>a feature that prevents a measuring element from being used while another measuring element is in use and is providing information to the indicator or printer.</Text></Paragraph></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489408" lims:id="1489408"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489409" lims:id="1489409">Test mode for display</MarginalNote><Label>16</Label><Text>A timber dimension measuring device must have a test mode that shows the functional status of all display elements and segments of its indicator if failure of any single element or segment will result in the display of incorrect information.</Text></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489410" lims:id="1489410"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489411" lims:id="1489411">Automatic ready condition</MarginalNote><Label>17</Label><Text>A timber dimension measuring device must automatically enter a ready condition when an object is not on or in the measuring element and, when the device is in that condition, that fact must be displayed on its indicator.</Text></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489412" lims:id="1489412"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489413" lims:id="1489413">Ready condition before measurement registration</MarginalNote><Label>18</Label><Text>A timber dimension measuring device must not display, transmit, print or store a measurement registration if it was not in a ready condition before taking the measurement.</Text></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489414" lims:id="1489414"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489415" lims:id="1489415">Tare function prohibited</MarginalNote><Label>19</Label><Text>A timber dimension measuring device must not use a process, mechanism or feature that reduces or adjusts the gross measured value of a log by a tare value, including a process, mechanism or feature that permits bark or other undesirable material to be subtracted from the measurement.</Text></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489416" lims:id="1489416"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489417" lims:id="1489417">Measurement registration elements</MarginalNote><Label>20</Label><Subsection lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489418" lims:id="1489418"><Label>(1)</Label><Text>All words, names, symbols and abbreviations that are part of a measurement registration must be displayed or marked on the timber dimension measuring device in a location in which they will not be obliterated or rendered illegible under the normal conditions of use of the device and that is clearly visible to the device’s operator and any customer who is present when a measurement is taken.</Text></Subsection><Subsection lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489419" lims:id="1489419"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489420" lims:id="1489420">Displayed or printed measurement registrations</MarginalNote><Label>(2)</Label><Text>A measurement registration that is displayed or printed by a timber dimension measuring device must</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489421" lims:id="1489421"><Label>(a)</Label><Text>be clear and unambiguous; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489422" lims:id="1489422"><Label>(b)</Label><Text>if the measurement registration is printed, be indelible.</Text></Paragraph></Subsection></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489423" lims:id="1489423"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489424" lims:id="1489424">Measurement registrations — auxiliary equipment</MarginalNote><Label>21</Label><Text>A measurement registration that is displayed or printed by auxiliary equipment must</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489425" lims:id="1489425"><Label>(a)</Label><Text>agree exactly with the measurement registration provided by the timber dimension measuring device;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489426" lims:id="1489426"><Label>(b)</Label><Text>be clear and unambiguous; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489427" lims:id="1489427"><Label>(c)</Label><Text>if the measurement registration is printed, be indelible.</Text></Paragraph></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489428" lims:id="1489428"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489429" lims:id="1489429">Prohibitions — measurements and measurement registrations</MarginalNote><Label>22</Label><Text>A timber dimension measuring device must not</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489430" lims:id="1489430"><Label>(a)</Label><Text>measure or calculate a log’s area or volume or take any other measurement that is calculated from the log’s length or diameter;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489431" lims:id="1489431"><Label>(b)</Label><Text>provide a measurement registration for a measurement or calculation referred to in paragraph (a);</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489432" lims:id="1489432"><Label>(c)</Label><Text>provide a measurement registration that has a negative measurement value; or</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489433" lims:id="1489433"><Label>(d)</Label><Text>provide a measurement registration for a log that has a length or diameter that is less than 10 d for the measuring range in use.</Text></Paragraph></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489434" lims:id="1489434"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489435" lims:id="1489435">Measuring range — minimum measurable value</MarginalNote><Label>23</Label><Subsection lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489436" lims:id="1489436"><Label>(1)</Label><Text>The minimum measurable value for each measuring range of a timber dimension measuring device must not be less than 10 d.</Text></Subsection><Subsection lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489437" lims:id="1489437"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489438" lims:id="1489438">Intervals for measuring ranges</MarginalNote><Label>(2)</Label><Text>If a timber dimension measuring device has more than one measuring range,</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489439" lims:id="1489439"><Label>(a)</Label><Text>the measuring ranges must be consecutive; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489440" lims:id="1489440"><Label>(b)</Label><Text>the interval of each measuring range must be smaller than the interval of the immediately superior measuring range.</Text></Paragraph></Subsection></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489441" lims:id="1489441"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489442" lims:id="1489442">Error message or blank measurement registration</MarginalNote><Label>24</Label><Text>A timber dimension measuring device must provide an error message or a blank measurement registration if</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489443" lims:id="1489443"><Label>(a)</Label><Text>it measures a log that is not within the limits of the dimensions marked on the device or on a plate that is affixed to the device;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489444" lims:id="1489444"><Label>(b)</Label><Text>it measures a log that is not within the detection limits of the device’s sensing component and the measurement value is not within the in-service limits of error referred to in section <XRefInternal>3</XRefInternal>; or</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489445" lims:id="1489445"><Label>(c)</Label><Text>its sensing component is obstructed when a measurement is taken and the measurement value is not within the in-service limits of error referred to in section <XRefInternal>3</XRefInternal>.</Text></Paragraph></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489446" lims:id="1489446"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489447" lims:id="1489447">Information to be recorded and stored</MarginalNote><Label>25</Label><Subsection lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489448" lims:id="1489448"><Label>(1)</Label><Text>A timber dimension measuring device must record and store the following information, or be connected to auxiliary equipment that records and stores that information, when a customer is not present at the time their logs are measured:</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489449" lims:id="1489449"><Label>(a)</Label><Text>for each log measured, its length and each measurement of its diameter; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489450" lims:id="1489450"><Label>(b)</Label><Text>if the logs are separated into lots, the lot identifier for, and number of logs in, each lot.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489451" lims:id="1489451"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489452" lims:id="1489452">Information provided to customer</MarginalNote><Label>(2)</Label><Text>The information referred to in subsection (1) must</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489453" lims:id="1489453"><Label>(a)</Label><Text>be recorded and stored in a manner that allows it to be provided to the customer; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489454" lims:id="1489454"><Label>(b)</Label><Text>be stored for a period of 90 days after the day on which it was recorded.</Text></Paragraph></Subsection></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489455" lims:id="1489455"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489456" lims:id="1489456">Auxiliary equipment interface</MarginalNote><Label>26</Label><Text>A timber dimension measuring device that is equipped with an interface that permits the connection of auxiliary equipment must be designed in a manner that prevents the metrological functions of the device from being adversely affected if the connected auxiliary equipment is exposed to an influence factor or a disturbance.</Text></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489457" lims:id="1489457"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489458" lims:id="1489458">Adjustable components</MarginalNote><Label>27</Label><Text>A component of a timber dimension measuring device that is physically or electronically adjusted must maintain that adjustment until any further adjustment is made to that component.</Text></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489459" lims:id="1489459"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489460" lims:id="1489460">Seals</MarginalNote><Label>28</Label><Text>The metrological functions and adjustable components of a timber dimension measuring device must be protected by</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489461" lims:id="1489461"><Label>(a)</Label><Text>physical seals that are readily accessible and observable and that make any access to those functions or components apparent; or</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489462" lims:id="1489462"><Label>(b)</Label><Text>electronic seals that make any access to those functions or components apparent, such as an audit trail that counts the number of changes made to the calibration or configuration parameters of the device or records the values related to these changes.</Text></Paragraph></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489463" lims:id="1489463"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489464" lims:id="1489464">Marking — general</MarginalNote><Label>29</Label><Subsection lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489465" lims:id="1489465"><Label>(1)</Label><Text>The following information must be permanently marked in a clearly visible location on a timber dimension measuring device or on a descriptive plate that is affixed to the device:</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489466" lims:id="1489466"><Label>(a)</Label><Text>the approval number assigned to the class, type or design of the device in accordance with paragraph 17(c) of the <XRefExternal reference-type="regulation" link="C.R.C.,_c._1605">Weights and Measures Regulations</XRefExternal>;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489467" lims:id="1489467"><Label>(b)</Label><Text>the name of the device’s manufacturer;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489468" lims:id="1489468"><Label>(c)</Label><Text>the device’s model designation;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489469" lims:id="1489469"><Label>(d)</Label><Text>the device’s serial number;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489470" lims:id="1489470"><Label>(e)</Label><Text>for each axis of measurement that the device is capable of measuring in the location where it is installed,</Text><Subparagraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489471" lims:id="1489471"><Label>(i)</Label><Text>the minimum and maximum dimensions for each measuring range on that axis, and</Text></Subparagraph><Subparagraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489472" lims:id="1489472"><Label>(ii)</Label><Text>the interval for each measuring range on that axis;</Text></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489473" lims:id="1489473"><Label>(f)</Label><Text>the number of scan heads installed on the device;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489474" lims:id="1489474"><Label>(g)</Label><Text>the device’s minimum and maximum operating speeds as installed;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489475" lims:id="1489475"><Label>(h)</Label><Text>the minimum distance, in centimetres or metres, between each log measured; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489476" lims:id="1489476"><Label>(i)</Label><Text>the temperature range specified for the device by the manufacturer, if any.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489477" lims:id="1489477"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489478" lims:id="1489478">Marking — temperature range</MarginalNote><Label>(2)</Label><Text>Despite paragraph (1)(i), a temperature range specified for the device by the manufacturer must not be marked on it or the descriptive plate unless the range spans at least 30°C and is entirely within the default temperature range.</Text></Subsection></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489479" lims:id="1489479"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489480" lims:id="1489480">Marking — other</MarginalNote><Label>30</Label><Text>The following information must be permanently marked on a timber dimension measuring device, or be posted near the device, in a location where the information is clearly visible to the device’s operator and any customer who is present when a measurement is taken:</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489481" lims:id="1489481"><Label>(a)</Label><Text>all restrictions, limitations or conditions on the use of the device; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489482" lims:id="1489482"><Label>(b)</Label><Text>all special applications or uses of the device.</Text></Paragraph></Section><Heading lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489483" lims:id="1489483" level="1"><TitleText>Installation and Use</TitleText></Heading><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489484" lims:id="1489484"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489485" lims:id="1489485">Requirements</MarginalNote><Label>31</Label><Subsection lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489486" lims:id="1489486"><Label>(1)</Label><Text>A timber dimension measuring device must be installed and used in a manner that</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489487" lims:id="1489487"><Label>(a)</Label><Text>ensures accurate measurement;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489488" lims:id="1489488"><Label>(b)</Label><Text>respects the parameters, restrictions and limitations set out in the notice of approval issued in respect of the device under section 3 of the <XRefExternal reference-type="act" link="W-6">Weights and Measures Act</XRefExternal>;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489489" lims:id="1489489"><Label>(c)</Label><Text>subject to section <XRefInternal>2</XRefInternal>, is in accordance with the instructions issued by its manufacturer or importer;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489490" lims:id="1489490"><Label>(d)</Label><Text>does not adversely affect the performance of the device;</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489491" lims:id="1489491"><Label>(e)</Label><Text>does not facilitate the perpetration of fraud; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489492" lims:id="1489492"><Label>(f)</Label><Text>ensures that any auxiliary equipment will not prevent the device from meeting the requirements of paragraphs (a) to (e).</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489493" lims:id="1489493"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489494" lims:id="1489494">Examination and testing</MarginalNote><Label>(2)</Label><Text>A timber dimension measuring device must be installed in a manner that enables it to be examined and enables physical test standards or test objects to be applied to it and recovered before they are processed by any other device.</Text></Subsection></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489495" lims:id="1489495"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489496" lims:id="1489496">Use — general</MarginalNote><Label>32</Label><Text>A timber dimension measuring device must only be used</Text><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489497" lims:id="1489497"><Label>(a)</Label><Text>in a manner that is consistent with its design, composition and construction; and</Text></Paragraph><Paragraph lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489498" lims:id="1489498"><Label>(b)</Label><Text>to measure logs that have a naturally occurring cross-section.</Text></Paragraph></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489499" lims:id="1489499"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489500" lims:id="1489500">Use — mobile equipment</MarginalNote><Label>33</Label><Text>A timber dimension measuring device that is an integral part of, or is attached or secured to, the frame, chassis, lifting mechanism or bed of mobile equipment — such as a truck, tractor, trailer or forklift — must not be supported by the wheels or treads of that equipment when the device is making a measurement.</Text></Section><Section lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-10-23" lims:fid="1489501" lims:id="1489501"><MarginalNote lims:inforce-start-date="2024-10-23" lims:enacted-date="2024-03-19" lims:fid="1489502" lims:id="1489502">Visibility of measurement registrations</MarginalNote><Label>34</Label><Text>A timber dimension measuring device must be installed in a manner that permits the operator, and any customer who is present when a measurement is taken, to observe the taking of the measurement and easily read the device’s indicator.</Text></Section><Heading lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489503" lims:id="1489503" level="1"><TitleText>Coming into Force</TitleText></Heading><Section lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:lastAmendedDate="2024-03-19" lims:fid="1489504" lims:id="1489504" type="CIFnobold"><MarginalNote lims:inforce-start-date="2024-03-19" lims:enacted-date="2024-03-19" lims:fid="1489505" lims:id="1489505">Publication</MarginalNote><Label>35</Label><Text>These Specifications come into force on the day on which they are published in the <XRefExternal reference-type="other" link="gazette">Canada Gazette</XRefExternal>, Part II.</Text></Section></Body></Regulation>