Government of Canada / Gouvernement du Canada
Symbol of the Government of Canada

Search

Energy Efficiency Regulations, 2016

Version of section 314 from 2017-06-28 to 2019-12-11:


Marginal note:Definitions

 The following definitions apply in this Division.

ASHRAE 103

ASHRAE 103 means the ANSI/ASHRAE standard 103-2007 entitled Method of Testing for Annual Fuel Utilization Efficiency of Residential Central Furnaces and Boilers. (ASHRAE 103)

automatic water temperature adjustment device

automatic water temperature adjustment device means a device that

  • (a) adjusts the temperature of the water supplied by a boiler to ensure that an incremental change in inferred heat load produces a corresponding incremental change in the temperature of the water supplied or, if the boiler fires at a single input rate, automatically allows the burner or heating element to fire only when the device has determined that the inferred heat load cannot be met by the residual heat of the water in the system; and

  • (b) when there is no inferred heat load, limits the water temperature in the boiler to not more than 60°C. (dispositif automatique de réglage de la température de l’eau)


Date modified: